October 20, 2022 NHTSA CAMPAIGN NUMBER: 22E090000
Electrical arcing can increase the risk of a fire.
NHTSA Campaign Number: 22E090
Manufacturer Carrier Corporation
Components EQUIPMENT
Potential Number of Units Affected 7,299
Summary
Carrier Corporation (Carrier
) is recalling certain Carrier
Transicold Refrigeration Units, model NDTP Supra S Series (S6, S7, S8, S9, S10). The 12-Volt wire harness on the truck refrigeration unit (TRU) may be exposed and missing heat shrink, which can cause electrical arcing.
Remedy
Dealers will inspect and secure/insulate exposed wires of the TRU, free of charge. Owner notification letters were mailed December 15, 2022. Owners may contact Carrier customer service at 1-800-448-1661. Carrier
’s number for this recall is R-968.
Notes
Owners may also contact the National Highway Traffic Safety Administration Vehicle Safety Hotline at 1-888-327-4236 (TTY 1-800-424-9153), or go to www.nhtsa.gov.
(74-50183-00) Supra Option Connector Rework
Models: Supra S6 – S10
Serial Number Range: Prior to VFH91727718
98-50468-00 Rev
12/7/2022
Purpose: The intent of this technical instruction is to provide guidelines for replacing the heat shrink tubing on the LIV, RRAT, RSAT, and Drain Water Resistor (DWR) wires. Additional connectors will be installed for the FLS, FHR, and Power Options. The F7 fuse will be removed from the TPC.
A 12 volt wire harness, used for the fuel heat option within the affected TRUs, may be exposed and missing heat shrink. The exposed, energized 12 volt wires, can, under certain conditions, lead to electrical arcing and possibly a fire. Failure to perform the inspection and installation work described in this letter as soon as possible could result in property damage or personal injury.
(74-50183-00) Supra Option Connector Rework
Models: Supra S6 – S10
Serial Number Range: Prior to VFJ91732331
98-50468-00 Rev B
2/23/2023
Purpose: The intent of this technical instruction is to provide guidelines for replacing the heat shrink tubing on the LIV, RRAT, RSAT, and Drain Water Resistor (DWR) wires. Additional connectors will be installed for the FLS, FHR, and Power Options. The F7 fuse will be removed from the TPC.
A 12 volt wire harness, used for the fuel heat option within the affected TRUs, may be exposed and missing heat shrink. The exposed, energized 12 volt wires, can, under certain conditions, lead to electrical arcing and possibly a fire. Failure to perform the inspection and installation work described in this letter as soon as possible could result in property damage or personal injury.
Chronology :
On August 16, 2022, Carrier received notification of a thermal incident involving a Supra S6 TRU in Aurora, CO.
On September 14, 2022, a field inspection was conducted, with an independent third-party fire investigator, into potential causes of the thermal event.
On September 20, 2022, a production line inspection showed that the affected TRU’s wire harness was missing the heat shrinks, such that the exposed wires in the harness may come into contact with surrounding metal or other exposed wires.
As a result, all shipments of affected TRUs were put on hold on September 22, 2022, and Carrier immediately began a careful analysis of the affected TRU’s wire harness to assess the potential product safety risk.
To date there has been only the one thermal event related to this issue, and no other field reports of arcing.
After much internal analysis and discussion with safety engineers, on October 20, 2022, Carrier determined that the issue presented a potential safety-related defect reportable to NHTSA under Part 573. That same business day, on October 20, 2022, Carrier
filed this 573 Defect and Non-Compliance Report.
1 Affected Product
Equipment
14 Associated Documents
Recall Acknowledgement
Defect Notice 573 Report
RCLRPT-22E090-8177.PDF 214.752KB
Remedy Instructions and TSB
RCRIT-22E090-8125.pdf 1175.118KB
Remedy Instructions and TSB
RCRIT-22E090-2712.pdf 70.021KB
Recall 573 Report – 1/13/2023
RCLRPT-22E090-6843.PDF 215.094KB
Recall Quarterly Report #1, 2022-4
RCLQRT-22E090-9214.PDF 211.13KB
ISSUED Owner Notification Letter(Part 577)
RCONL-22E090-8908.pdf 142.24KB
Recall Quarterly Report #2, 2023-1
RCLQRT-22E090-4808.PDF 211.225KB
Remedy Instructions and TSB
RCRIT-22E090-3953.pdf 1175.554KB
Remedy Instructions and TSB
RCRIT-22E090-0394.pdf 1218.617KB
Recall Quarterly Report #3, 2023-2
RCLQRT-22E090-8508.PDF 211.316KB
Recall Quarterly Report #4, 2023-3
RCLQRT-22E090-1649.PDF 211.565KB
ISSUED Renotification Notice
RCRN-22E090-1506.pdf 511.034KB
Manufacturer Notices(to Dealers,etc)-R-1000 Second Notice Dealer Email.
RCMN-22E090-2247.pdf 668.007KB
Latest Recalls Documents
“This site contains affiliate links for which OEMDTC may be compensated” |
- 3:1 SHRINK RATIO & FAST CONTRACTON SPEED: Shrinks to 1/3 of its original diameter and seals extremelytightly, solving the problem of many 2:1 shrink tubes that don't shrink enough and therefore don't sealtightly enough, Shrink temperature: 80 to 125°C, Provides a professional connection within seconds.
- INCLUDES ADHESIVE COATING: When the heat shrink tubing is heated, it automatically releases adhesive and seals the connection extremely reliably. This creates a waterproof and durable insulation with a satisfaction quarantee.
- DUAL WALL TUBING: The outer wall of the shrink tube provides extremely high abrasion resistance. The inner wall creates a consistently waterproof seal and excellent strain relief. Our solder connectors will also impress you!
- 7 SIZES: We offer 7 of the most commonly used shrink tube diameters in the world, ranging from 3/32" to 3/4". All of our shrink tubes are pre-cut to 1.77 inches.
- VERSATILE APPLICATIONS: The waterproof Eventronic shrink tubing can be used in marine and automotive wiring, model building, and DiY electrical wiring projects. The application areas are very diverse, such as electrical insulation/environmental sealing to protect against moisture, fuel and chemicals/protection of surfaces against abrasion, peeling and denting.
- BIG COLLECTION – Totally 580pcs,11 specifications: 1/24"(80pcs),1/16"(80pcs),1/12"(100pcs),3/64"(30pcs),1/8"(60pcs),9/64"(30pcs),5/32"(70pcs),1/5"(30pcs),15/64"(20pcs),5/16"(20pcs),25/64"(60pcs).
- 2:1 SHRINK RATIO – When heat, it will shrink up to 1/2 of original diameter,makes it possible to repair most damaged cable jackets without removing connectors. Ratio: 2:1 Operating Temperature: -55°C to + 125°C
- EASY TO USE – 1,Choose a right size of tubes, insert the wires into the tube, slip it into place after the connection is made. 2, Keep the nozzle about 2" distance from the tube, apply heat at a 45 degree angle until the tube tightly shrunk around the joint.
- WELL ORGANIZED – Comes with a plastic organizer, the tubes place in 16 separated compartments, providing an organized way to help you identify the right sizes quickly, classify easily.. 6 colors are for color coding to help identify cables such as red for power, black for ground.
- WIDELY APPLICATION - Repairing phone and headphone cables, electrical insulation, identifying wires (by the colors), organizing the messy cables/wires, lights wiring, home repair projects.
- 900 PCS WIRE HEAT SHRINK TUBING KIT LINED: 2:1 Industrial heat-shrink tubing for wires include: 1/24 (1.0mm) 200 pcs, 1/16 (1.5mm) 200 pcs, 1/12 (2.0mm) 100 pcs, 1/10 (2.5mm) 80 pcs, 1/8 (3.0mm) 60 pcs, 1/7 (3.5mm) 50 pcs, 1/6 (4mm) 50 pcs, 1/5 (5mm) 40 pcs, 1/4 (6mm) 30 pcs, 2/7 (7mm) 30 pcs, 2/5 (10mm) 30 pcs, 1/2 (13mm) 30 pcs, length: 1.77 inch(45 mm), total 900 pcs, 12 Sizes, 6 Colors. Our colored marine heat shrink tubing satisfied for your different need.
- PREMIUM MATERIAL: Our color industrial heat-shrink tubing for wires made of polyolefin, shrinkage ratio: 2:1, and makes a tight seal. Our colored wire shrink wrap tubing has good electrical insulation, corrosion resistance and high temperature resistance.
- EASY TO USE AND STORE: 12 Sizes of premium marine grade heat shrink wrap for you to choose, all packed in a plastic box for easy store and carry. Simply slide heat shrink tubing be over your connection point and apply heat, professional connections made in seconds, waterproof and long-lasting insulation.
- WIDELY USED: Our color marine grade heat shrink wrap suitable for wire connection, rust prevention and corrosion protection of solder joints, cable joints, protection and insulation processing of wire end, wiring harness. Our large electrical waterproof heat shrink tape also works well for protecting headphones and phone cables.
- SATISFIED SERVICE: We are committed to providing every customer premium large electrical waterproof heat shrink tape and satisfied service. If there are any problems with our wire heat shrink tubing kit lined, contact us, we will give you a satisfactory answer.
- 3:1 SHRINK RATIO - Recovers to 1/3 of its original diameter, and makes a tight seal. Eliminates the problem of 2:1 tubing not shrinking tight enough.
- GLUE INSIDE - When heat is applied, adhesive comes out and seals the connection, creating resistant and long-lasting insulation.
- VARIETY OF SIZES - We have included 7 most commonly used diameters ranging from 3/32" to 3/4". Shrink tubing is precut to 3.5 inches.
- EASY TO USE - Simply slide heat shrink tube over your connection point and apply heat. Professional connections made in seconds.
- DUAL WALL TUBING & TRUSTED UL CERTIFICATION - Outer wall provides abrasion resistance. Inner wall creates resistant seal and strain relief. Independently verified by UL for quality and safety, giving you confidence in every use.
- 3:1 Shrink Ratio & Quick Contraction Speed: This tubing heat shrinks to one-third of its original diameter, ensuring a tight seal that overcomes the limitations of many other shrink tubing that don’t shrink sufficiently. With a shrink temperature range of 80 to 125°C, it provides a professional and secure connection in seconds.
- Adhesive Coating for Secure Sealing: Heating the shrink tubing activates the adhesive, creating an extremely reliable seal. This ensures waterproof and durable insulation, guaranteed to satisfy.
- Available Sizes: We offer a selection of 7 widely-used shrink tube diameters, from 1/8",3/16”,1/4", 3/8", 1/2", 3/4" and 1. All tubes come pre-cut to 1.75 inches.
- Dual Wall Design: The wire heat shrink tubing outer wall offers high abrasion resistance, and the inner wall creates a reliable waterproof seal, along with superior strain relief.
- Wide Range of Applications: Eventronic waterproof heat shrink tubing is perfect for marine and automotive wiring, model building, and DIY electrical projects. heat shrink wire tubing offers versatile protection, including electrical insulation, moisture, fuel, and chemical sealing, as well as safeguarding surfaces from abrasion, peeling, and damage.
- 1.Pakage Included: Upgrade 446pcs 4:1 Ratio,7 most commonly used diameters ranging from 3/32" to 3/4". Shrink tubing is precut to 1.75" inches.
- 2.High Shrinkage Ratio: 4:1 SHRINK RATIO, it can shrink to 1/4 of the original diameter,Shrink tighter and seal better than 3:1 and 2:1. Suitable for more application.the shrinkage temperature is 125°C (257°F), and the withstand voltage is 600V.Wire Cable shrink wrap.High flame retardant coefficient.
- 3.Glue Inside: Shrink Tubing for Wires,When the Heat-shrink tube shrinks, the glue film on the inner wall will melt and then it will be adsorbed on the surface of the object tightly so as to connect tightly, insulate, and seal off perfectly. Eliminates the problem of 3:1 and 2:1 tubing not shrinking tight enough. It has the advantages of waterproofing, moisture-proof, wear-resistant, anti-skidding, heat-resistant, tensile-resistant, anti-aging, and corrosion resistance.
- 4.Easy to Use: Only need to cut the required size heat shrinkable tube, slide it to the required position and then use the hot air gun so that the professional insulation connection is completed in a few seconds finaly.
- 5.Wide Range of Applications: Heat shrinkable tubing is mainly used in data line ,industry, boats and ships, wire connections,rust and corrosion prevention of solder joints, audios, electrical equipment and DIY etc. Besides, it is also used in wire end, wire harness, electronic protection and insulation treatment, fitness equipment handle and steel structure surface protection etc.
- INCLUDES ADHESIVE COATING: When heat is applied, adhesive comes out and seals the connection, creating waterproof and long-lasting insulation. This creates a waterproof and durable insulation with a satisfaction guarantee
- DUAL WALL TUBING: Outer wall provides abrasion resistance. Inner wall creates waterproof seal and strain relief. Our solder connectors will also impress you
- 3:1 SHRINK RATIO & FAST CONTRACTION SPEED: Recovers to 1/3 of its original diameter, and makes a tight seal. Eliminates the problem of 2:1 tubing not shrinking tight enough. Shrink temperature: 80 to 125°C. Provides a professional connection within seconds
- VARIETY OF SIZES: We offer larger diameter heat shrink tubing ranging from 1/8" to 1". Shrink tubing is precut to 1.75 inches
- FUNCTIONAL WIRE SHRINK WRAP TUBING: Covers all gauges of heat shrink wires you'll need in RC hobbies and many other applications. Heat shrink tubing assortment is mainly used in wire connection, rust prevention and corrosion protection of solder joints, protection and insulation processing of wire end, wiring harness and electronic components. Also works well for protecting headphones and phone cables
- Effective and Long Lasting Protection: innhom heat tube shrink has the advantages of good tightness, acid and alkali resistance, durable and anti-aging. Shrink wrap wire tensile strength: 14 Mpa. Dielectric strength: >20kV/mm. Elongation at break: >400%. Volume resistivity: >1.0× 10^14Ω.cm. Cold-resistant bending -22℉(-30 °C) × 1h without cracking. Use innhom heat shrink tubes instead of ugly and short-lived electric tape.
- Functional Wire Shrink Wrap Tubing: Covers all gauges of heat shrink wires you'll need in RC hobbies and many other applications. innhom heat shrink tubing assortment is mainly used in wire connection, rust prevention and corrosion protection of solder joints, protection and insulation processing of wire end, wiring harness and electronic components. Also works well for protecting headphones and phone cables.
- What You Get: Total 650pcs shrinkage ratio 2:1 Black heat shrink tubes, 8 sizes. Supplied internal diameter, 150-1/24", 120-1/12", 100-1/8", 90-1/6", 80-1/5", 50-1/4", 30-5/16", 30-2/5". Single length 1 4/7". All packed in a plastic case for easy storage. innhom wire shrink tubing can ensure your pleasant shopping experience.
- Premium Quality Heat Shrink Tubing Set: Excellent flame retardant and insulation performance. Soft and flexible wire shrink wrap, low shrinkage temperature-minimum shrinkage temp: +158℉(+70°C), fast shrinkage, easy and convenient to use with a heat gun.
- Excellent Material Shrink Wrap: Electrical heat shrink tubing material composition does not contain heavy metal and other environmentally hazardous substances. No slowly or long-term virulence. No need to worry about your health when using innhom heat shrink wrap.
- [Better protection]: double wall heat shrink tube and lined with glue can better act on the wrapped objects.
- [A wide range of applications] Shrink tube are mainly used for industrial, ship, wire links, anti-rust and anti-corrosion protection of solder joints, and audio and electrical DIY. Wire ends, harnesses, electronics protection and insulation treatment, fitness equipment parts and steel structure surface protection and so on.
- [The rubber liner has good sealing performance] XHF heat-shrinkable tube has the advantages of good electrical insulation, good sealing, corrosion resistance and high temperature resistance. Anti-aging, tough, not easy to break.
- [Easy and fast] You only need to heat it evenly with a hot air blower or a candle to make it shrink. It is a 3:1 heat shrink ratio and will shrink to the original 1/3.
- [Diversity] We have three kinds of shrinkage (2:1, 3:1, 4:1) heat shrink tubes for you to choose from.
- Material:Made of Polyolefin, Shrinkage Ratio:2:1 (will shrink to 1/2 its supplied diameter)
- Suitable for electrical insulation, wire bundling, colour coding, mechanical protection,wire/cable joints and daily repairs etc
- Comes with 560pcs heat shrink tube assorted in plastic box, 5 colors( Yellow, Blue, Black,Green, Red), 12 Specifications , satisfied for your different need
- Length: 1 13/16", Internal Diameter: 1/24"(90 Pcs), 1/16"(70 Pcs), 1/12"(70 Pcs), 1/10" (50 Pcs), 1/8"(50 Pcs), 1/7*(50 Pcs), 1/6"(50 Pcs), 1/5"(30 Pcs), 1/4"(30 Pcs), 2/7*(25 ! Pcs), 2/5"(25 Pcs), 1/2*(20 Pcs)
- Package Included: 1 x 560PCS(12 sizes) 2:1 Heat Shrink Tubing
Last update on 2025-04-17 / Affiliate links / Images from Amazon Product Advertising API
This product presentation was made with AAWP plugin.
SEOCONTENT-START
IMPORT ANT SAFETY MESSAGE
Carrier
TRANSICOLD
11/30/2023
IMPORTANT SAFETY RECALL
SECOND NOTICE
NHTSA Recall No. 22E-090
This second notice is sent to you in accordance with the National Traffic and Motor Vehicle
Safety Act.
Dear Valued Customer:
As explained in our prior customer notification letter dated December 19, 2022, Carrier
Transicold has decided that a defect which relates to motor vehicle safety exists in Supra
series S6, S7, S8, S9 and S10 diesel truck refrigeration units (together, the “affected TRUS”).
Our records indicate that affected TRUs are registered to your company under the serial
number(s) listed in the attachment to this letter.
This is a safety recall SECOND NOTICE under the National Traffic and Motor
Vehicle Safety Act. Failure to perform the inspection and installation work described in this
letter as soon as possible could result in property damage or personal injury.
The 12-volt wire harness, used for the fuel heat option within the affected TRUs, may
be exposed and missing heat shrink. The exposed, energized 12-volt wires can, under certain
conditions, lead to electrical arcing and possibly a fire.
If your authorized Carrier Transicold dealer has not contacted you to arrange an
inspection of all affected TRUs shown in the attachment to this letter, please reach out to
them to coordinate the inspection. The inspection and rework will be provided at no charge
to you. During that inspection, the dealer will straight cut any exposed wires in the harness,
apply new heat shrink for some wires, add a connector to the remaining wires, and remove a
fuse. The inspection and securing of an affected TRU’s 12-volt harness will take
approximately 1.5 hours.
Carrier Transicold dealers have also received a reminder that the defect is present, and
that the affected TR Us’ 12-volt harness should be inspected and reworked. If your Carrier
Transicold dealer has already completed this inspection and rework in accordance with this
reminder, no further action is required. If you are unsure whether this occurred, please confirm
with your dealer as soon as possible. If you believe you have previously completed the remedy
work described in this notification letter and such work was not covered by the manufacturer’s
warranty, or you otherwise were obligated to pay for such work, please contact your dealer for
reimbursement, if appropriate. Should you need help locating an authorized Carrier Transicold
dealer in your area, wish to confirm whether your Carrier Transicold equipment is affected by
this second notice or have any other questions, please call the Carrier Transicold Action Line at
800-448-1661.
Federal law requires any lessor who receives a notification of a determination of a
safety-related defect or noncompliance pertaining to any leased motor vehicle to send the
notice to the lessee within l O days.
If you believe that Carrier Transicold has failed to remedy the defect without charge, or
if you believe that Carrier Transicold has failed to remedy the defect (without charge) within
sixty (60) days of your first attempt to obtain the repair, you may submit a complaint to the
Administrator, National Highway Traffic Safety Administration, 1200 New Jersey Avenue
SE, Washington, DC 20590, or call the toll-free Vehicle Safety Hotline at 1-888-327-4236
(TTY: 1800-424-9153), or go to http://www.safercar.gov.
Regards,
Carrier Transicold Service Engineering
( l) attachment
2
Customer Affected TRU Serial Number List
3
**************************************************************************************************************
98-50468-00 Rev 12/7/2022 Page 1 of 8
(74-50183-00) Supra Option Connector Rework
Models: Supra S6 – S10
Serial Number Range: Prior to VFH91727718
Purpose: The intent of this technical instruction is to provide guidelines for replacing the heat shrink tubing on the LIV, RRAT, RSAT, and Drain Water Resistor (DWR) wires. Additional connectors will be installed for the FLS, FHR, and Power Options. The F7 fuse will be removed from the TPC.
A 12 volt wire harness, used for the fuel heat option within the affected TRUs, may be exposed and missing heat shrink. The exposed, energized 12 volt wires, can, under certain conditions, lead to electrical arcing and possibly a fire. Failure to perform the inspection and installation work described in this letter as soon as possible could result in property damage or personal injury.
Kit Parts
Part A B C D E
F G H I J K L
Quantity 2
2
5
5
3
3
6
10
5
4
8
3
Part Number 22-01585-04
22-02392-03
22-02393-00
22-02393-01
22-02394-00
22-02394-02
22-02394-03
22-50078-55
22-50078-58D
66-U—1–3882
66-U—1–8292-5
Alcohol Wipe
Part Description Connector (Cap) Male, 4 Pin Connector Female, 4 Pin
Terminal, Male 14-16 AWG (3.6 mm)¹
Terminal, Male 18-20 AWG (3.0 mm)¹ Seal, Cable (Grey)
Seal, Cable (Green) Seal, Cable (Purple) Plug, Cavity
Terminal, 12 AWG (4.6 mm)¹ Cable Tie
Cap Wipe 1. Terminal dimension (mm) is the width between conductor crimp wings. Refer to option bundle step 4. Additional Required Parts
Part Quantity Part Number Part Description
A1 1 02-00137-00M25 Tape, Harness Required Tools Tool Part Number Part Description 07-00487-00 Heat Gun 07-00370-00 Crimper, Weather Pack Obtain Locally Pliers, Flush Cut Obtain Locally Scissors Obtain Locally Wire stripper Obtain Locally M10 Socket/Wrench Unit may start automatically at any time even if switch is in the OFF position. Use proper lockout / tagout procedures before inspection / servicing. All unit inspection / servicing to be performed by properly trained personnel only. Option Bundle
Two connectors will be used in place of heat shrink for the wires at the option bundle. The wires installed in the connectors will vary depending on the model. Refer to the following table for wire/connector position and seal/terminal part reference. For units with an option installed the rework is not required for that option. S6-S9 S10
Position Wire Color/mm2 Seal Terminal Position Wire Color/mm2 Seal Terminal A FHR-1
B FHR-2
C FHR-5
D FHR-4 White (3.0) E I
White (1.5) G D
Green (1.5) G D
Green (3.0) E I A PWR OPT-A
B Plug
C Plug
D PWR OPT-B White F C H
H
Green F C A FLS-A
B FLS-B
C FLS-C
D Plug White (1.0) G D
Green (1.0) G D
White (1.0) G D H A FLS-A
B FLS-B
C FLS-C
D Plug White (1.0) G D
Green (1.0) G D
White (1.0) G D H Table 1. Option Bundle Connector Wire/Part Reference 98-50466-00 Rev 12/7/2022 Page 2 of 8 Locate the harness option bundle near the control box Inspect to verify if any of the options are installed. If an option is installed, rework for that option is not required. 1 Rework ALL unused options listed in table 1 Locate the wires with heat shrink installed that are listed in table 1 Cut the wire ends to remove the existing heat shrink
2
Cut Here Install seals on the wires Note: Three sizes of seals are included in the kit. Select seal based on table 1. Strip the wire ends
3 Position seal at end of insulation Crimp terminals and seals to the wire. Use the appropriate die position for the size terminal being crimped. Note: Three sizes of terminals are included in the kit. Select terminal based on table 1. Terminal size
4 is measured at width of conductor wings. mm 3.0
3.6
4.6 Item D C
I 98-50466-00 Rev 12/7/2022 Page 3 of 8 Fill each cap (A) with 4 plugs (H) and secure cap lock. Insert plugs and seals/terminals in connector (B) per table 1. Pull on wires to verify crimp and terminal installation 5 Pull on wires to verify crimp and terminal installation. Terminals MUST be securely crimped on the wire and
terminals fully seated in the connector Secure connectors to harness with cable tie between wire tie bases on the control box. 6 98-50466-00 Rev 12/7/2022 Page 4 of 8 F7 Fuse Removal Locate the TPC cover at the rear of the control box. Remove the four nuts securing the cover. 1
10 Remove the fuel heat (F7) fuse and discard. Reinstall the TPC cover and tighten the nuts. 2 10 44 in-lbs (5 Nm) 98-50466-00 Rev 12/7/2022 Page 5 of 8 LIV
The heat shrink on the LIV wire will be removed and replaced. Locate LIV wires at CSMV and cut cable tie securing to harness. 1 Cut wires so that 3.00 (75mm) extends out of the harness and the existing heat shrink is removed. Clean the wire ends with alcohol wipe (L) 2
Wipe Install heat shrink caps (K) on both of the wires and use heat gun to seal. Allow the heat shrink to cool and pull on cap to verify that it is secure. If cap comes off install new cap and heat to seal 3
Allow the heat shrink to cool and pull on cap to verify it is secure. If cap comes off install new cap and heat to seal. Cap must be secure. 98-50466-00 Rev 12/7/2022 Page 6 of 8 Apply tape (A1) to harness to secure LIV harness leg/wires to the harness main . 4 Evaporator
The heat shrink on the DWR, RRAT, and RSAT wires will be removed and replaced. Locate the option bundle in evaporator section. Inspect to verify if any of the options are installed. If an option is installed, rework for that option is not required. Rework the DWR, RRAT, and RSAT options if not
1 installed.
Cut cable ties at the locations shown to access the bundle. Cut the ends of the RRAT, RSAT, DWR1-1,
DWR1-2, DWR2-1, and DWR2-2 wires so that 3.00 (75mm) extends out of the harness and the original heat shrink is removed. Clean wire ends with alcohol swab (L).
2
Wipe 98-50466-00 Rev 12/7/2022 Page 7 of 8 98-50466-00 Rev 12/7/2022 Page 8 of 8
3
Install heat shrink cap (K) on each of the wires and use heat gun to seal. Allow the heat shrink to cool and pull on cap verify it is secure. If cap comes off install new cap and heat to seal.
Allow the heat shrink to cool and pull on cap to verify it is secure. If cap comes off install new cap and heat to seal. Caps must be secure.
4
Wrap wire ends together with tape (A1) . Continue wrapping tape to end to cover heat shrink.
5
Bundle harness as shown and secure harness with
cable tie (J) to cable tie base.
**************************************************************************************************************
98-50468-00 Rev B 2/23/2023 Page 1 of 8
(74-50183-00) Supra Option Connector Rework
Models: Supra S6 – S10
Serial Number Range: Prior to VFJ91732331
Purpose: The intent of this technical instruction is to provide guidelines for replacing the heat shrink tubing on the LIV, RRAT, RSAT, and Drain Water Resistor (DWR) wires. Additional connectors will be installed for the FLS, FHR, and Power Options. The F7 fuse will be removed from the TPC.
A 12 volt wire harness, used for the fuel heat option within the affected TRUs, may be exposed and missing heat shrink. The exposed, energized 12 volt wires, can, under certain conditions, lead to electrical arcing and possibly a fire. Failure to perform the inspection and installation work described in this letter as soon as possible could result in property damage or personal injury.
Kit Parts
Part A B C D E
F G H I J K L
Quantity 2
2
5
5
3
3
6
10
5
4
8
3
Part Number 22-01585-04
22-02392-03
22-02393-00
22-02393-01
22-02394-00
22-02394-02
22-02394-03
22-50078-55
22-50078-58D
66-U—1–3882
66-U—1–8292-5
Alcohol Wipe
Part Description Connector (Cap) Male, 4 Pin Connector Female, 4 Pin
Terminal, Male 14-16 AWG (3.6 mm)¹
Terminal, Male 18-20 AWG (3.0 mm)¹ Seal, Cable (Grey)
Seal, Cable (Green) Seal, Cable (Purple) Plug, Cavity
Terminal, 12 AWG (4.6 mm)¹ Cable Tie
Cap Wipe 1. Terminal dimension (mm) is the width between conductor crimp wings. Refer to option bundle step 4. Additional Required Parts
Part Quantity Part Number Part Description
A1 1 02-00137-00M25 Tape, Harness Required Tools Tool Part Number Part Description 07-00487-00 Heat Gun 07-00370-00 Crimper, Weather Pack Obtain Locally Pliers, Flush Cut Obtain Locally Scissors Obtain Locally Wire stripper Obtain Locally M10 Socket/Wrench Unit may start automatically at any time even if switch is in the OFF position. Use proper lockout / tagout procedures before inspection / servicing. All unit inspection / servicing to be performed by properly trained personnel only. Option Bundle
Two connectors will be used in place of heat shrink for the wires at the option bundle. The wires installed in the connectors will vary depending on the model. Refer to the following table for wire/connector position and seal/terminal part reference. For units with an option installed the rework is not required for that option. S6-S9 S10
Position Wire Color/mm2 Seal Terminal Position Wire Color/mm2 Seal Terminal A FHR-1
B FHR-2
C FHR-5
D FHR-4 White (3.0) E I
White (1.5) G D
Green (1.5) G D
Green (3.0) E I A PWR OPT-1
B PWR OPT-2
C PRW OPT-3
D Plug White (0.75) F C
White (0.75) F C
White (0.75) F C H A FLS-A
B FLS-B
C FLS-C
D Plug White (1.0) G D
Green (1.0) G D
White (1.0) G D H A FLS-A
B FLS-B
C FLS-C
D Plug White (1.0) G D
Green (1.0) G D
White (1.0) G D H Table 1. Option Bundle Connector Wire/Part Reference 98-50468-00 Rev B 2/23/2023 Page 2 of 8 Locate the harness option bundle near the control box Inspect to verify if any of the options are installed. If an option is installed, rework for that option is not required. 1 Rework ALL unused options listed in table 1 Locate the wires with heat shrink installed that are listed in table 1 Cut the wire ends to remove the existing heat shrink
2
Cut Here Install seals on the wires Note: Three sizes of seals are included in the kit. Select seal based on table 1. Strip the wire ends
3 Position seal at end of insulation Crimp terminals and seals to the wire. Use the appropriate die position for the size terminal being crimped. Note: Three sizes of terminals are included in the kit. Select terminal based on table 1. Terminal size
4 is measured at width of conductor wings. mm 3.0
3.6
4.6 Item D C
I 98-50468-00 Rev B 2/23/2023 Page 3 of 8 Fill each cap (A) with 4 plugs (H) and secure cap lock. Insert plugs and seals/terminals in connector (B) per table 1. Pull on wires to verify crimp and terminal installation 5 Pull on wires to verify crimp and terminal installation. Terminals MUST be securely crimped on the wire and
terminals fully seated in the connector Secure connectors to harness with cable tie between wire tie bases on the control box. 6 98-50468-00 Rev B 2/23/2023 Page 4 of 8 F7 Fuse Removal Locate the TPC cover at the rear of the control box. Remove the four nuts securing the cover. 1
10 Remove the fuel heat (F7) fuse and discard. Reinstall the TPC cover and tighten the nuts. 2 10 44 in-lbs (5 Nm) 98-50468-00 Rev B 2/23/2023 Page 5 of 8 LIV
The heat shrink on the LIV wire will be removed and replaced. Locate LIV wires at CSMV and cut cable tie securing to harness. 1 Cut wires so that 3.00 (75mm) extends out of the harness and the existing heat shrink is removed. Clean the wire ends with alcohol wipe (L) 2
Wipe Install heat shrink caps (K) on both of the wires and use heat gun to seal. Allow the heat shrink to cool and pull on cap to verify that it is secure. If cap comes off install new cap and heat to seal 3
Allow the heat shrink to cool and pull on cap to verify it is secure. If cap comes off install new cap and heat to seal. Cap must be secure. 98-50468-00 Rev B 2/23/2023 Page 6 of 8 Apply tape (A1) to harness to secure LIV harness leg/wires to the harness main . 4 Evaporator
The heat shrink on the DWR, RRAT, and RSAT wires will be removed and replaced. Locate the option bundle in evaporator section. Inspect to verify if any of the options are installed. If an option is installed, rework for that option is not required. Rework the DWR, RRAT, and RSAT options if not
1 installed.
Cut cable ties at the locations shown to access the bundle. Cut the ends of the RRAT, RSAT, DWR1-1,
DWR1-2, DWR2-1, and DWR2-2 wires so that 3.00 (75mm) extends out of the harness and the original heat shrink is removed. Clean wire ends with alcohol swab (L).
2
Wipe 98-50468-00 Rev B 2/23/2023 Page 7 of 8 98-50468-00 Rev B 2/23/2023 Page 8 of 8
3
Install heat shrink cap (K) on each of the wires and use heat gun to seal. Allow the heat shrink to cool and pull on cap verify it is secure. If cap comes off install new cap and heat to seal.
Allow the heat shrink to cool and pull on cap to verify it is secure. If cap comes off install new cap and heat to seal. Caps must be secure.
4
Wrap wire ends together with tape (A1) . Continue wrapping tape to end to cover heat shrink.
5
Bundle harness as shown and secure harness with
cable tie (J) to cable tie base.
**************************************************************************************************************
© Carrier Corporation 2022
SER22-047 12/16/2022 SUBJECT: Field Action R-1000 for Supra Series
The above field action is active for Supra Series units SFD91487875 to VFJ91732331. A 12 volt wire harness, used for the fuel heat option within the affected TRUs, may be exposed and missing heat shrink. The exposed, energized 12 volt wires, can, under certain conditions, lead to electrical arcing and possibly a fire. Failure to perform the inspection and installation work as detailed in Technical Instruction 98-50466-00 could result in property damage or personal injury. Dealers are encouraged to address this safety-related field action as soon as possible.
Kit 74-50183-00 is required and will be available from the Performance Parts Group (PPG) in the coming weeks. To meet initial demand across the network, dealers should order only the quantity required to perform the field action in the next four to six weeks. Additional quantities of the kit will be forthcoming, and PPG will review orders for this kit to ensure adequate distribution across the network until availability increases.
From the date that the kit is available, the network will be reimbursed an incentive to perform the field action per the following schedule:
If the date of repair minus kit available date is
o up to two months, that claim will receive 110% of the field action dollars,
o up to three months, that claim will receive 105% of the field action dollars,
o greater than three months, that claim will receive 100% of the field action dollars.
Dealers may request transportation costs (SER21-049) to perform the field action on fleets with 10+ assets where delivery to the dealer is prohibitive.
The incentive and transportation costs are associated only with this field action and will be evaluated for their effectiveness in the future.
Inquiries regarding adjustments for particular situations should be made through your FSE.
WebClaim 2.0 is preloaded with the affected serial numbers and a field action claim can be input using R-1000.
**************************************************************************************************************
1
IMPORTANT SAFETY MESSAGE
12/19/2022
IMPORTANT SAFETY RECALL
NHTSA Recall No. 22E-090
Customer Name Customer Address
Dear Valued Customer:
This notice is sent to you in accordance with the National Traffic and Motor Vehicle Safety Act.
Carrier Transicold has decided that a defect which relates to motor vehicle safety exists in Supra series S6, S7, S8, S9 and S10 diesel truck refrigeration units (together, the “affected TRUs”). Our records indicate that affected TRUs are registered to your company under the serial number(s) listed in the attachment to this letter.
This is a safety recall notice under the National Traffic and Motor Vehicle Safety Act. Failure to perform the inspection and installation work described in this letter as soon as possible could result in property damage or personal injury.
The 12-volt wire harness, used for the fuel heat option within the affected TRUs, may be exposed and missing heat shrink. The exposed, energized 12-volt wires, can, under certain conditions, lead to electrical arcing and possibly a fire.
Your authorized Carrier Transicold dealer will contact you to arrange to have all affected TRUs shown in the attachment to this letter or otherwise in your possession inspected. The inspection and rework will be provided at no charge to you. During that inspection, the dealer will straight cut any exposed wires in the harness, apply new heat shrink for some wires, add a connector to the remaining wires, and remove a fuse. The inspection and securing of an affected TRU’s 12-volt harness will take approximately 1.5 hours.
Carrier Transicold dealers have also received notice that the defect is present, and that the affected TRUs’ 12-volt harness should be inspected and reworked. If your Carrier Transicold dealer has already completed this inspection and rework in accordance with this notice, no further action is required. If you are unsure whether this occurred, please confirm with your dealer as soon as possible. If you believe you have previously completed the remedy work described in this notification letter and such work was not covered by the manufacturer’s
2
warranty, or you otherwise were obligated to pay for such work, please contact your dealer for reimbursement, if appropriate. Should you need help locating an authorized Carrier Transicold dealer in your area, wish to confirm whether your Carrier Transicold equipment is affected by this notice or have any other questions, please call the Carrier Transicold Action Line at 800-448-1661.
Federal law requires any lessor who receives a notification of a determination of a safety-related defect or noncompliance pertaining to any leased motor vehicle shall send the notice to the lessee within 10 days.
If you believe that Carrier Transicold has failed to remedy the defect without charge, or if you believe that Carrier Transicold has failed to remedy the defect (without charge) within sixty (60) days of your first attempt to obtain the repair, you may submit a complaint to the Administrator, National Highway Traffic Safety Administration, 1200 New Jersey Avenue SE, Washington, DC 20590, or call the toll-free Vehicle Safety Hotline at 1-888-327-4236 (TTY: 1800-424-9153), or go to http://www.safercar.gov.
Regards,
Carrier Transicold Service Engineering
(1) attachment
3
Customer Affected TRU Serial Number List
**************************************************************************************************************
1
McDonald, Patrick From: Holder, Huck
Sent: Tuesday, December 19, 2023 21:45
To:
Cc: McDonald, Patrick
Subject: Field Action R-1000 for Supra Series
Attachments: Reminder Letter R-1000.docx Good Afternoon,
Please find attached the reminder letter that was mailed to customers this week regarding the Supra Series recall notice.
Here is the list of serial numbers that we still show outstanding:
Thanks for your support and happy holidays!
Huck
Huck Holder | Product Services Engineering Operations Manager | Carrier
Transicold 700 Olympic Dr. | Athens, GA 30601 |
**************************************************************************************************************
OMB Control No.: 2127-0004
Part 573 Safety Recall Report 22E-090
The information contained in this report was submitted pursuant to 49 CFR §573
Manufacturer Name : Submission Date :
Carrier Corporation OCT 20, 2022 NHTSA Recall No. : 22E-090 Manufacturer Recall No. : R-968 Manufacturer Information :
Manufacturer Name : Carrier Corporation Address : P.O. Box 4805
Carrier Parkway, TR-20 Syracuse NY 13221
Company phone : 315-432-3572
Population :
Number of potentially involved : 7,299 Estimated percentage with defect : 95 %
Equipment Information : Brand / Trade 1 :
Model : Carrier Transicold
NDTP Supra S Series (S6, S7, S8, S9, S10) Part No. : 22-61124 Size : N/A Function : Refrigeration
Descriptive Information : The Supra S6, S7, S8, S9 and S10 (NDTP) models of diesel truck refrigeration unit (together, the “affected TRU”) are sold by Carrier Corporation’s Carrier Transicold Division (“Carrier”) and are designed and used to maintain the temperature of frozen and/or chilled products during on-road truck transport.
The affected TRUs come with a 12V wire harness to provide power for a fuel heater post-production add-on accessory.
Production Dates : JAN 01, 2016 – SEP 22, 2022
Description of Defect :
Description of the Defect : The 12-V wire harness of the affected TRUs contain live power and have been found to be exposed when not attached to the postproduction fuel heater accessory, with stripped wire ends and a missing protection heat shrink.
FMVSS 1 : NR FMVSS 2 : NR
Description of the Safety Risk : The exposed, live wires in the 12V wire harness in the affected TRUs could
potentially ground or have intermittent connection with surrounding cut wires or other metal components, which could lead to electrical arcing and localized heat. Hot copper from the wire could ignite a flame which could propagate to components in the surrounding area. Description of the Cause : In the affected TRUs the wire harness is missing the heat shrink that protects Part 573 Safety Recall Report 22E-090 Page 2 Identification of Any Warning
that can Occur : the stripped wire ends, either as a result of not being installed by the supplier or falling off after production.
Visual inspection should clearly show the missing heat shrink in the area of concern on the wire harness. Involved Components : Component Name : NR Component Description : NR Component Part Number : NR Supplier Identification : Component Manufacturer
Name : Electrical Components International Address : 1 City Place Drive
Suite 450 St. Louis Missouri 63141
Country : United States Chronology :
On August 16, 2022, Carrier received notification of a thermal incident involving a Supra S6 TRU in Aurora, CO. On September 14, 2022, a field inspection was conducted, with an independent third-party fire investigator, into potential causes of the thermal event. On September 20, 2022, a production line inspection showed that the affected TRU’s wire harness was missing the heat shrinks, such that the exposed wires in the harness may come into contact with surrounding metal or other exposed wires. As a result, all shipments of affected TRUs were put on hold on September 22, 2022, and Carrier immediately began a careful analysis of the affected TRU’s wire harness to assess the potential product safety risk. To date there has been only the one thermal event related to this issue, and no other field reports of arcing. After much internal analysis and discussion with safety engineers, on October 20, 2022, Carrier determined that the issue presented a potential safety-related defect reportable to NHTSA under Part 573. That same business day, on October 20, 2022, Carrier filed this 573 Defect and Non-Compliance Report. The information contained in this report was submitted pursuant to 49 CFR §573 Part 573 Safety Recall Report 22E-090
Page 3
The information contained in this report was submitted pursuant to 49 CFR §573
Description of Remedy :
Description of Remedy Program : Carrier will ask all end user customers to have their affected TRUs
inspected by an authorized Carrier dealer. The dealer will, at no cost to end user customers, inspect and install the specified heat shrinks on the exposed wires, with an adhesive property to reduce the likelihood of the heat shrink falling off, within the affected TRU. How Remedy Component Differs from Recalled Component : Identify How/When Recall Condition was Corrected in Production : Carrier Transicold is modifying the affected TRUs in the field by cutting off the stripped portion of the wire, and adding the heat shrink that contains an adhesive property to reduce the likelihood of the heat shrink falling off within the affected TRU.
All affected TRUs shipped on and after September 28, 2022, will have all of the wire ends cut off to remove the stripped and exposed ends, and replaced with new heat shrink with adhesive properties; and removal of 20AMP fuse F7 to ensure the wires are no longer live. Recall Schedule :
Description of Recall Schedule : On or before December 20, 2022, Carrier plans to send notice of the
updated inspection and field retrofit plan for affected TRUs via email to all authorized dealers located in the U.S., and plans to send notice of the updated inspection and field retrofit plan for affected TRUs via U.S. Mail to all known end user customers located in the U.S.
Planned Dealer Notification Date : DEC 19, 2022 – DEC 19, 2022
Planned Owner Notification Date : DEC 19, 2022 – DEC 19, 2022 Purchaser Information :
The following manufacturers purchased this defective/noncompliant equipment for possible use or installation in new motor vehicles or new items of motor vehicle equipment:
Name : NR Address : NR
NR Country : NR Company Phone : NR
* NR – Not Reported
**************************************************************************************************************
OMB Control No.: 2127-0004
Part 573 Safety Recall Report 22E-090
The information contained in this report was submitted pursuant to 49 CFR §573
Manufacturer Name : Submission Date :
Carrier Corporation JAN 13, 2023 NHTSA Recall No. : 22E-090 Manufacturer Recall No. : R-968 Manufacturer Information :
Manufacturer Name : Carrier Corporation Address : P.O. Box 4805
Carrier Parkway, TR-20 Syracuse NY 13221
Company phone : 315-432-3572
Population :
Number of potentially involved : 7,299 Estimated percentage with defect : 95 %
Equipment Information : Brand / Trade 1 :
Model : Carrier Transicold
Supra S Series (S6, S7, S8, S9, S10) Part No. : 22-61124 Size : N/A Function : Refrigeration
Descriptive Information : The Supra S6, S7, S8, S9 and S10 models of diesel truck refrigeration unit (together, the “affected TRU”) are sold by Carrier Corporation’s Carrier Transicold Division (“Carrier”) and are designed and used to maintain the temperature of frozen and/or chilled products during on-road truck transport. The affected TRUs come with a 12V wire harness to provide power for a fuel heater post-production add-on accessory.
Production Dates : JAN 01, 2016 – SEP 22, 2022
Description of Defect :
Description of the Defect : The 12-V wire harness of the affected TRUs contain live power and have been found to be exposed when not attached to the postproduction fuel heater accessory, with stripped wire ends and a missing protection heat shrink.
FMVSS 1 : NR FMVSS 2 : NR
Description of the Safety Risk : The exposed, live wires in the 12V wire harness in the affected TRUs could
potentially ground or have intermittent connection with surrounding cut wires or other metal components, which could lead to electrical arcing and localized heat. Hot copper from the wire could ignite a flame which could propagate to components in the surrounding area and result in an increased risk of fire. Description of the Cause : In the affected TRUs the wire harness is missing the heat shrink that protects Part 573 Safety Recall Report 22E-090 Page 2 Identification of Any Warning
that can Occur : the stripped wire ends, either as a result of not being installed by the supplier or falling off after production.
Visual inspection should clearly show the missing heat shrink in the area of concern on the wire harness. Involved Components : Component Name : 12-volt engine harness
Component Description : 12-volt engine harness (supplied by ECI) that provides power for a fuel heater add-on accessory
Component Part Number : 22-61124-01 (S6), 22-61124-00 (S7, S8), 22-61125-00 (S9), 22-61125-21 (S10) Supplier Identification : Component Manufacturer
Name : Electrical Components International Address : 1 City Place Drive
Suite 450 St. Louis Missouri 63141
Country : United States Chronology :
On August 16, 2022, Carrier received notification of a thermal incident involving a Supra S6 TRU in Aurora, CO. On September 14, 2022, a field inspection was conducted, with an independent third-party fire investigator, into potential causes of the thermal event. On September 20, 2022, a production line inspection showed that the affected TRU’s wire harness was missing the heat shrinks, such that the exposed wires in the harness may come into contact with surrounding metal or other exposed wires. As a result, all shipments of affected TRUs were put on hold on September 22, 2022, and Carrier immediately began a careful analysis of the affected TRU’s wire harness to assess the potential product safety risk. To date there has been only the one thermal event related to this issue, and no other field reports of arcing. After much internal analysis and discussion with safety engineers, on October 20, 2022, Carrier determined that the issue presented a potential safety-related defect reportable to NHTSA under Part 573. That same business day, on October 20, 2022, Carrier filed this 573 Defect and Non-Compliance Report. The information contained in this report was submitted pursuant to 49 CFR §573 Part 573 Safety Recall Report 22E-090
Page 3
The information contained in this report was submitted pursuant to 49 CFR §573
Description of Remedy :
Description of Remedy Program : Carrier will ask all end user customers to have their affected TRUs
inspected by an authorized Carrier dealer. The dealer will, at no cost to end user customers, inspect and install the specified heat shrinks on the exposed wires, with an adhesive property to reduce the likelihood of the heat shrink falling off, within the affected TRU. Owners who seek reimbursement for the cost of a repair or remedy for this issue prior to Carrier’s notification are encouraged to contact their respective Dealer to submit the claim; if needed, more information about the procedure for pre-notification reimbursement claims may be found in the Manufacturer Pre-Notification Reimbursement Plan associated with this recall. The Plan also includes an address to which claims may be mailed. How Remedy Component Differs from Recalled Component : Identify How/When Recall Condition was Corrected in Production : Carrier Transicold is modifying the affected TRUs in the field by cutting off the stripped portion of the wire, and adding the heat shrink that contains an adhesive property to reduce the likelihood of the heat shrink falling off within the affected TRU.
All affected TRUs shipped on and after September 28, 2022, will have all of the wire ends cut off to remove the stripped and exposed ends, and replaced with new heat shrink with adhesive properties; and removal of 20AMP fuse F7 to ensure the wires are no longer live. Recall Schedule :
Description of Recall Schedule : On or before December 19, 2022, Carrier plans to send notice of the
updated inspection and field retrofit plan for affected TRUs via email to all authorized dealers located in the U.S., and plans to send notice of the updated inspection and field retrofit plan for affected TRUs via U.S. Mail to all known end user customers located in the U.S.
Planned Dealer Notification Date : DEC 24, 2022 – DEC 24, 2022
Planned Owner Notification Date : DEC 15, 2022 – DEC 21, 2022 Purchaser Information :
The following manufacturers purchased this defective/noncompliant equipment for possible use or installation in new motor vehicles or new items of motor vehicle equipment:
Name : NR Address : NR
NR Country : NR Company Phone : NR
* NR – Not Reported
SEOCONTENT-END