March 22, 2024 NHTSA CAMPAIGN NUMBER: 24V222000
Inadequate Clearance For Electrical Fuse Terminal
Contact with the main fuse terminal can cause electrical arcing, increasing the risk of a fire.
NHTSA Campaign Number: 24V222
Manufacturer Reading Truck Equipment LLC
Components ELECTRICAL SYSTEM
Potential Number of Units Affected 48
Summary
Reading Truck Equipment, LLC (Reading) is recalling certain 2021-2024 dump body trucks. Inadequate clearance may allow the hood to contact the main electrical fuse terminal.
Remedy
Dealers will inspect and relocate fuse terminal and fuse, free of charge. Owner notification letters are expected to be mailed March 29, 2024. Owners may contact Reading customer service at 1-800-458-2226.
Notes
Owners may also contact the National Highway Traffic Safety Administration Vehicle Safety Hotline at 1-888-327-4236 (TTY 1-800-424-9153), or go to www.nhtsa.gov.
Ford Super Duty Under-hood Electrical Component Relocation
Purpose:
- Relocate electrical components installed in low clearance zones, as identified by Ford
Service Bulletin Q-277.
General Information:
- Please reference Ford
Service Bulletin Q-277 located at: https://fordbbas.com/bulletins
- Configuration 1 โ RTE-09542 Relocation bracket required.
- Configuration 2 โ CTE-5511 Relocation bracket required.
Chronology :
Reading Truck Equipment was made aware of a warranty claim due to a thermal event of a dump body installed on a Ford medium duty truck chassis on 03/12/2024.
Reading inspected the truck on 03/20/2024 and established that the root cause for the thermal event was due to the dump body primary fuse not installed to provide sufficient hood underside clearance.
Reading Truck Equipment decided to declare a recall related to this due to the safety risk on 03/21/2024
4 Affected Products
Vehicle
MAKE | MODEL | YEAR |
READING TRUCK EQUIPMENT | DUMP BODIED TRUCKS | 2021-2024 |
6 Associated Documents
Recall Acknowledgement
RCAK-24V222-8180.pdf 645.966KB
Defect Notice 573 Report
RCLRPT-24V222-7827.PDF 213.676KB
Manufacturer Notices(to Dealers,etc)
RCMN-24V222-8553.pdf 1135.109KB
Remedy Instructions and TSB
RCRIT-24V222-9043.pdf 434.827KB
Recall 573 Report – 04/12/2024
RCLRPT-24V222-1991.PDF 213.712KB
Recall 573 Report – 04/12/2024
RCLRPT-24V222-9381.PDF 213.712KB
Latest Recalls Documents
For the Latest and Most recent Recall Information Visit the link below…
- Top-Quality Material: Constructed with brass, ensuring durability and resistance to corrosion for long-lasting use
- Easy Installation: Featuring an insert-style connector, allowing for a quick and easy installation process
- Temperature Rating: Rated for temperatures up to 257 degrees Fahrenheit, suitable for various applications
- Versatile Usage: Compatible as a ring terminal for fuse boxes, auto insurance, and auto meters
- QUICK FIX: When the current or voltage exceeds the rated limits, the fuse will automatically blow. Each load is equipped with an LED indicator to signal whether a circuit has shorted or if the fuse has blown, allowing for easy identification and replacement. However, it is important to note that there may still be voltage present across the circuit even in the absence of a fuse; this occurs because the fuse box contains its own lighting circuit, which introduces resistance and consequently displays some voltage.
- ENSURE NEAT WIRING: Rather than cluttering your battery terminals with a tangle of wires and fuse holders, the WUPP 12-volt fuse block and ground bus kit provides six dedicated fuses and six grounding points to maintain an organized, clean, and easily accessible wiring system. This simplifies the process of wiring electronics in your vehicle or boat.
- UNIVERSAL PROTECTION: The input rated voltage of the fuse box is 32V,and the input rated current is 100A.Each circuit outputs a maximum current of 30A. All bus bars and fuse pieces are nickel-plated copper, corrosion-resistant and highly conductive.
- SAFE MATERIAL: PBT flame retardant material base,good mechanical strength and high temperature resistance. It is insulated, heat resistant and flame resistant. There will hardly cause any issue like produce fracture, deformation, combustion or short circuit phenomenon.
- FREE BLADE FUSES: 6-Way Package includes: 20A Fuse*4, 15A Fuse*4, 10A Fuse*2, 5A Fuse*2, Labels*2, Screws*4
- Voltage Max Operating: 58V DC, Amps Max Operating: 300A per block, Terminal Fuses Avail.: 30A-300A, Terminal Stud Size: 5/16"-18 (8mm), Mounting Hole Size: #10 (5mm)3/8"
- Compact, high-amp fuseโappropriate for DC Main, inverter, windlass, and bow thruster circuit protection
- Weatherproof โ suitable for small open-cockpit boats and other harsh environments
- Insulating cap prevents accidental shorts
- Ignition protected when used with MRBF fuses
- Dual-slot Fuse Holder: Provides 1 fuse holder to protect existing circuits and a second fuse holder to protect new circuit. Blue flexible socket tail, very easy to connect to any naked wires by only use a vise
- Easy to use: plugs into occupied or vacant energized fuse block slot. Easy installation of additional circuits without splicing or cutting
- Great compatibility: Automotive and non-automotive use for Cars, Trucks, SUVs, ATVs, UTVs, Campers
RVs,Motorcycles,Boats,snowmobiles,and most general DC applications etc,covering such components as radio, light,etc. Use when hardwiring or adding LED strips, dash cams or other electronic devices that require direct wiring into the fuse box
- Superior quality: made from high quality materials, good bending performance, melting resistance and excellent electrical conductivity
- Package include: 3pcs Standdard fuse tap,3pcs Mini
fuse tap,3pcs Micro2 fuse tap,3pcs Low Profile mini
fuse tap,12pcs blade fuses.
- Blue Sea Systems Fuse Block ST Blade 4 Circuit Battery Terminal, part number 5023
- Max Amps: 100A per block, 30A per circuit, Max Volts: 32V DC, Mounting: Clearance for 3/8" (M10) stud, Screw Terminal Torque: 18in-lb, Screw terminal type: #8-32 screws with captive star
- Easy to install 4 ATO/ATC fused circuits
- Mounts on the battery terminal stud
- Four Nylon insulated ring terminals, insulating cover and 1 fuse included
- Function: The fuse block provides multiple fuse circuits, distribute electricity from an incoming supply to different branch circuits to supply lights and other electrical appliance with electricity. The advantage of using fuse block is that only the faulty circuit will be interrupted when a fault occurs, and the normal circuits are unaffected. Thus preventing a possible hazards.
- Easy Installation: This fuse box is very easy to install. Each positive terminal screw has a negative terminal screw to make wiring very easy. Provide a simplified way for wire connection as well as keeping all your circuit wiring in order.
- Safety Design: When the current is too high or the wire shorts, the fuse will blow to avoid potential safety hazards. The label DIY stickers can make you instantly and accurately identify and replace the blown fuse. The Transparent plastic cover with push latch design is easy to operate. The cover is splash and dust-proof. Provides extra protection to your fuse box and fuses.
- Common Use: Widely used in 10V-32V DC Cars, Boats, Trucks, Trailers, Buses, RVs, RZRs, UTVs, Yachts etc. Each fuse can be connected to any electrical circuits like LED light bar, headlights, fog lights, tail lights, Rock lights, rocker switch, toggle switch, etc.
- Package Includes: A 6 way fuse block, label stickers and extra fuses.
- Product type :FISHING EQUIPMENT
- 10,000 AIC at 14V DC satisfies ABYC requirements for DC Main circuit protection on large battery banks
- Requires the use of Terminal Fuse Blocks PN 5191 or PN 2151โdo not mount the fuse directly to the battery terminal
- Package dimensions :7.62 cm L x3.556 cm W x2.54 cm H
SEOCONTENT-START
NHTSA Recall
Date:
2024
Page:
Revision:
24V222
3-25-
1 0f 6
0
SAFETY RECALL NOTICE
TO: All Reading Truck Dealers
Reading Truck Equipment has decided that a safety defect exists in certain dump body trucks built
f rom 2021 th ru 2024. Accord ingly, a recall to address this issue is being init iated effective
3/ 25/ 2024.
Reading Truck Equipment has found that the primary dump body fuse may have been installed
incorrectly and may not provide sufficient clearance to the underside of the vehicle hood. This may
resu lt in electrical arcing, increasing the risk of a fire, crash and/ or injury.
Owners will be notified by mail about the reca ll and will be instructed to make an appointment to have
their vehicle(s) inspected and the fuse terminal and fuse relocated at a Reading Truck Equipment or
Reading Truck Equipment authorized service location.
There is no cost to owners for th is recall.
Please follow the “Ford Super Duty Under-hood Electrical Component Relocation Instructions” below
and complete a warranty claim for reimbursement of parts and labor.
Please be reminded that it is a violation of Federal law for you to sell or lease the trucks as per VIN
listing below, until th is reca ll has been performed on these trucks. Substant ial civil penalties apply to
violations of this law.
VIN Vehicle Make Vehicle Model Vehicle Year
FORD F350 2024
FORD 4X4F550 2022
FORD 4X4F450C 2023
FORD 4X4F450 2023
FORD 4X4F550 2023
FORD 4X4F550 2023
FORD F550 2022
FORD 4X4F450C 2023
FORD 4X4F450C 2023
FORD 4X4F550S 2023
FORD 4X4F450S 2023
FORD 4X4F450S 2023
FORD 4X4F550C 2022
FORD F550 2022
FORD F450 2023
FORD F550 2021
FORD F550 2021
FORD F350 2022
FORD F450CC 2022
FORD 4X4F600 2022
readingtruck.com 825 E. Wyomissing Blvd., Reading, PA 19611
readingtruck.com 825 E. Wyomissing Blvd., Reading, PA 19611
NHTSA Recall 24V222
Date: 3-25-
2024
Page: 2 of 6
Revision: 0
FORD F350 2022
FORD F350 2023
FORD 4X4F550 2023
FORD 4X4F550 2023
FORD 4X4F550 2023
FORD 4X4F450 2023
FORD F350 2023
FORD F250 2023
FORD F250 2023
FORD F250 2023
FORD F250 2023
FORD F550 2022
FORD 4X4F450 2022
FORD 4X4F550 2022
FORD F450 2021
FORD 4X4F550 2022
FORD 4X4F550C 2022
FORD F250 2022
FORD F550 2022
FORD F350 2022
FORD F550 2022
FORD F450 2022
FORD 4X4F550C 2022
FORD F550 2022
FORD 4X4F550C 2022
FORD F550 2022
FORD 4X4F350C 2022
FORD 4X4F350C 2022
Your assistance with this recall is appreciated. Should you have any questions or concerns, please
contact the Reading Truck Warranty department at 1-800-458-2226 (option 3), or send an e-mail to
warranty@readingtruck.com
Sincerely,
Brian Verbonitz
Warranty Manager
Reading Truck
readingtruck.com 825 E. Wyomissing Blvd., Reading, PA 19611
NHTSA Recall 24V222
Date: 3-25-
2024
Page: 3 of 6
Revision: 0
Ford Super Duty Under-hood Electrical Component Relocation Instructions
Purpose:
โข Relocate electrical components installed in low clearance zones, as identified by Ford Service
Bulletin Q-277.
General Information:
โข Please reference Ford Service Bulletin Q-277 located at: https://fordbbas.com/bulletins
โข Configuration 1 โ RTE-09542 Relocation bracket required.
o Ford Super Duty gas engine, single or dual battery.
o Ford Super Duty diesel engine, with components located in the low clearance zone,
passenger side.
โข Configuration 2 โ CTE-5511 Relocation bracket required.
o Ford Super Duty diesel engine, with components located in the low clearance zone,
driver side.
Repair Procedure:
Tools:
โข General socket set and wrenches.
โข Drill and drill bits.
โข Wire strippers/cutters.
โข Wire crimpers.
Supplies:
โข RTE-09542 or CTE-5511 mounting bracket, as required.
โข Electrical tape, convoluted loom, wire ends, and wire as necessary.
โข For Configuration 2 only:
o (2) ยผ-20 X 1โ hex head bolts
o (2) ยผโ flat washers
o (2) ยผ-20 nuts
1. Park vehicle on a level surface and turn off engine.
2. Disconnect batteries.
3. Identify components in low clearance zones, per Ford Bulletin Q-277. For chassis identified in
Configuration 1, continue to step 4. For chassis identified in Configuration 2, skip to step 5.
4. For Configuration 1 relocation:
a. Disconnect any wires and remove mounting hardware from the original electrical
component installation.
b. Install supplied mounting bracket, part number RTE-09542, on the battery hold down
post, closest to the firewall. See Figure 1 and 2 below for reference. If components are
mounted on the driver side battery, it is acceptable to use the supplied bracket on the
driver side battery hold down post in this configuration, see Figure 3 for reference.
c. Install component onto the newly added mounting bracket.
d. Re-connect wires
readingtruck.com 825 E. Wyomissing Blvd., Reading, PA 19611
NHTSA Recall 24V222
Date: 3-25-
2024
Page: 4 of 6
Revision: 0
Figure 1
Figure 2
Figure 3
5. For Configuration 2 relocation:
a. Disconnect any wires and remove mounting hardware from the original electrical
component installation.
b. Pre-mount the fuse holder to the supplied mounting bracket, P/ N CTE-5511 (Figure 4).
c. Hold the bracket in place on the fire wall f lange, rough ly 1″ f rom the inside of the
fender. Make sure there is a minimum of 3/ 8″ clearance around the fuse holder.
d. Mark the two mounting holes and drill with 9/ 32″ drill bit.
e. Install the bracket/fuse holder assembly onto the firewall using supplied ยผ-20
hardware. See Figu re 5 for reference.
f. Re-connect wires.
Figure4
Figure5
6. Once complete, take pictures of the relocated bracket with fuse holder, fuse, and terminated
wiring.
readingtruck.com 825 E. Wyomissing Blvd., Reading, PA 19611
readingtruck.com 825 E. Wyomissing Blvd., Reading, PA 19611
NHTSA Recall 24V222
Date: 3-25-
2024
Page: 6 of 6
Revision: 0
7. Fill out the information below and send a copy of this page along with the repair photos to:
Email: warranty@readingtruck.com
Please fill out the following information:
Date: __________ VIN:_____________________
(complete V.I.N.)
Company: ______________________________
Address: ______________________________
_____________________________________
City:___________ State:_________ Zip:__________
Phone:__________________ Contact___________________
Contact Information:
Reading Truck Warranty
Email: warranty@readingtruck.com
Phone: 1-800-458-226 (Option 3)
Technical Support: 1-800-458-2226 Ext. 16279 Cell: 484-638-0116
**************************************************************************************************************
OMB Control No.: 2127-0004
Part 573 Safety Recall Report 24V-222
The information contained in this report was submitted pursuant to 49 CFR ยง573
Manufacturer Name : Submission Date :
Reading Truck Equipment LLC MAR 22, 2024 NHTSA Recall No. : 24V-222 Manufacturer Recall No. : NR Manufacturer Information :
Manufacturer Name : Reading Truck Equipment LLC Address : 825 E Wyomissing Blvd
Reading PA 19611
Company phone : 18004582226
Population :
Number of potentially involved : 48 Estimated percentage with defect : 50 %
Vehicle Alterer Information :
Vehicle 1 : 2021-2024 Reading Truck Equipment Dump Body
Descriptive Information : Population was established by reviewing quality final inspection as built photographs of 770 trucks to establish location of the dump body fuse. The 48 units potentially involved in this recall need to be inspected for compliance to the Ford Service Bulletin Q-277 by a Reading Truck Equipment service location and repaired if non-compliance is confirmed.
Production Dates : FEB 11, 2021 – MAR 01, 2024
Description of Defect :
Description of the Defect : The dump body primary electrical fuse installed close to vehicle battery with insufficient clearance to the engine side of the vehicle hood as per Ford Service Bulletin Q-277.
FMVSS 1 : NR FMVSS 2 : NR
Description of the Safety Risk : Insufficient clearance between fuze terminal and underside of the vehicle
hood may result in a potential thermal event in some vehicles.
Description of the Cause : The dump body primary electrical fuse installed close to vehicle battery with insufficient clearance to the engine side of the vehicle hood as per Ford Service Bulletin Q-277. Identification of Any Warning
that can Occur : Underhood smoke
Involved Components : Part 573 Safety Recall Report 24V-222 Page 2 Component Name : NR Component Description : NR Component Part Number : NR Supplier Identification : Component Manufacturer
Name : NR Address : NR
NR
Country : NR Chronology :
Reading Truck Equipment was made aware of a warranty claim due to a thermal event of a dump body installed on a Ford medium duty truck chassis on 03/12/2024.
Reading inspected the truck on 03/20/2024 and established that the root cause for the thermal event was due to the dump body primary fuse not installed to provide sufficient hood underside clearance.
Reading Truck Equipment decided to declare a recall related to this due to the safety risk on 03/21/2024 Description of Remedy :
Description of Remedy Program : The 48 affected customers/owners will be notified by certifiied mail of the
recall, but to accelarate the process, Reading Truck Equipment will also contact the affected customers/owners via e-mail and telephone calls. The 48 affected customers/owners will be requested to bring the affected vehicle to a Reading Truck Equipment Service location, for inspection and repair. The inspection and repair will be performed at no charge to the customer/owner and will take 2 hours. How Remedy Component Differs from Recalled Component :
Identify How/When Recall Condition was Corrected in Production : The fuse and terminal will be re-located to provide sufficient clearance per the Ford Service Bullein Q-277
Reading Truck Equipment issued a Quality Alert to all Reading Truck Equipment upfit locations on 09/05/2020 with the Ford Service Bulletin Q-277.
Reading Truck Equipment added this a quality inspection item on 09/05/2020 with a requirment to take photographs of as-built equipment. The information contained in this report was submitted pursuant to 49 CFR ยง573 Part 573 Safety Recall Report 24V-222
Page 3
The information contained in this report was submitted pursuant to 49 CFR ยง573
Recall Schedule :
Description of Recall Schedule : NR
Planned Dealer Notification Date : MAR 29, 2024 – APR 15, 2024
Planned Owner Notification Date : MAR 29, 2024 – APR 15, 2024
Purchaser Information :
The following manufacturers purchased this defective/noncompliant equipment for possible use or installation in new motor vehicles or new items of motor vehicle equipment:
Name : Address :
Country : Company Phone :
* NR – Not Reported
**************************************************************************************************************
readingtruck.com 825 E. Wyomissing Blvd., Reading, PA 19611
NHTSA Recall 24V222
Date: 3-25-2024
Page: 1 of 4
Revision: 0
Ford Super Duty Under-hood Electrical Component Relocation
Purpose:
๏ท Relocate electrical components installed in low clearance zones, as identified by Ford Service Bulletin Q-277.
General Information:
๏ท Please reference Ford Service Bulletin Q-277 located at: https://fordbbas.com/bulletins
๏ท Configuration 1 โ RTE-09542 Relocation bracket required.
o Ford Super Duty gas engine, single or dual battery.
o Ford Super Duty diesel engine, with components located in the low clearance zone, passenger side.
๏ท Configuration 2 โ CTE-5511 Relocation bracket required.
o Ford Super Duty diesel engine, with components located in the low clearance zone, driver side.
Repair Procedure:
Tools:
๏ท General socket set and wrenches.
๏ท Drill and drill bits.
๏ท Wire strippers/cutters.
๏ท Wire crimpers.
Supplies:
๏ท RTE-09542 or CTE-5511 mounting bracket, as required.
๏ท Electrical tape, convoluted loom, wire ends, and wire as necessary.
๏ท For Configuration 2 only:
o (2) ยผ-20 X 1โ hex head bolts
o (2) ยผโ flat washers
o (2) ยผ-20 nuts
1. Park vehicle on a level surface and turn off engine.
2. Disconnect batteries.
3. Identify components in low clearance zones, per Ford Bulletin Q-277. For chassis identified in Configuration 1, continue to step 4. For chassis identified in Configuration 2, skip to step 5.
4. For Configuration 1 relocation:
a. Disconnect any wires and remove mounting hardware from the original electrical component installation.
b. Install supplied mounting bracket, part number RTE-09542, on the battery hold down post, closest to the firewall. See Figure 1 and 2 below for reference. If components are mounted on the driver side battery, it is acceptable to use the supplied bracket on the driver side battery hold down post in this configuration, see Figure 3 for reference.
c. Install component onto the newly added mounting bracket.
readingtruck.com 825 E. Wyomissing Blvd., Reading, PA 19611
NHTSA Recall 24V222
Date: 3-25-2024
Page: 2 of 4
Revision: 0
d. Re-connect wires
Figure 1
Figure 2
Figure 3
readingtruck.com 825 E. Wyomissing Blvd., Reading, PA 19611
NHTSA Recall 24V222
Date: 3-25-2024
Page: 3 of 4
Revision: 0
5. For Configuration 2 relocation:
a. Disconnect any wires and remove mounting hardware from the original electrical component installation.
b. Pre-mount the fuse holder to the supplied mounting bracket, P/N CTE-5511 (Figure 4).
c. Hold the bracket in place on the fire wall flange, roughly 1โ from the inside of the fender. Make sure there is a minimum of 3/8โ clearance around the fuse holder.
d. Mark the two mounting holes and drill with 9/32โ drill bit.
e. Install the bracket/fuse holder assembly onto the firewall using supplied ยผ-20 hardware. See Figure 5 for reference.
f. Re-connect wires.
Figure 4
Figure 5
readingtruck.com 825 E. Wyomissing Blvd., Reading, PA 19611
NHTSA Recall 24V222
Date: 3-25-2024
Page: 4 of 4
Revision: 0
6. Once complete, take pictures of the relocated bracket with fuse holder, fuse, and terminated wiring.
7. Fill out the information at the bottom of page 4. Send a copy of page 4 along with the repair photos to:
Email: warranty@readingtruck.com
Please fill out the following information:
Date: __________ VIN:_____________________
(complete V.I.N.)
Company: ______________________________
Address: ______________________________
_____________________________________
City:___________ State:_________ Zip:__________
Phone:__________________ Contact___________________
Contact Information:
Reading Truck Warranty
Email: warranty@readingtruck.com
Phone: 1-800-458-226 (Option 3)
Technical Support: 1-800-458-2226 Ext. 16279 Cell: 484-638-0116
**************************************************************************************************************
OMB Control No.: 2127-0004
Part 573 Safety Recall Report 24V-222
The information contained in this report was submitted pursuant to 49 CFR ยง573
Manufacturer Name : Submission Date :
Reading Truck Equipment LLC APR 12, 2024 NHTSA Recall No. : 24V-222 Manufacturer Recall No. : NR Manufacturer Information :
Manufacturer Name : Reading Truck Equipment LLC Address : 825 E Wyomissing Blvd
Reading PA 19611
Company phone : 18004582226
Population :
Number of potentially involved : 48 Estimated percentage with defect : 50 %
Vehicle Alterer Information :
Vehicle 1 : 2021-2024 Reading Truck Equipment Dump Body
Descriptive Information : Population was established by reviewing quality final inspection as built photographs of 770 trucks to establish location of the dump body fuse. The 48 units potentially involved in this recall need to be inspected for compliance to the Ford Service Bulletin Q-277 by a Reading Truck Equipment service location and repaired if non-compliance is confirmed.
Production Dates : FEB 11, 2021 – MAR 01, 2024
Description of Defect :
Description of the Defect : The dump body primary electrical fuse installed close to vehicle battery with insufficient clearance to the engine side of the vehicle hood as per Ford Service Bulletin Q-277.
FMVSS 1 : NR FMVSS 2 : NR
Description of the Safety Risk : Insufficient clearance between fuze terminal and underside of the vehicle
hood may result in a potential thermal event in some vehicles.
Description of the Cause : The dump body primary electrical fuse installed close to vehicle battery with insufficient clearance to the engine side of the vehicle hood as per Ford Service Bulletin Q-277. Identification of Any Warning
that can Occur : Underhood smoke
Involved Components : Part 573 Safety Recall Report 24V-222 Page 2 Component Name : Electrical fuse mounting bracket Component Description : Bracket
Component Part Number : RTE-08569 Supplier Identification : Component Manufacturer
Name : NR Address : NR
NR
Country : NR Chronology :
Reading Truck Equipment was made aware of a warranty claim due to a thermal event of a dump body installed on a Ford medium duty truck chassis on 03/12/2024.
Reading inspected the truck on 03/20/2024 and established that the root cause for the thermal event was due to the dump body primary fuse not installed to provide sufficient hood underside clearance.
Reading Truck Equipment decided to declare a recall related to this due to the safety risk on 03/21/2024 Description of Remedy :
Description of Remedy Program : The 48 affected customers/owners will be notified by certifiied mail of the
recall, but to accelarate the process, Reading Truck Equipment will also contact the affected customers/owners via e-mail and telephone calls. The 48 affected customers/owners will be requested to bring the affected vehicle to a Reading Truck Equipment Service location, for inspection and repair. The inspection and repair will be performed at no charge to the customer/owner and will take 2 hours. How Remedy Component Differs from Recalled Component :
Identify How/When Recall Condition was Corrected in Production : The fuse and terminal will be re-located to provide sufficient clearance per the Ford Service Bullein Q-277
Reading Truck Equipment issued a Quality Alert to all Reading Truck Equipment upfit locations on 09/05/2020 with the Ford Service Bulletin Q-277.
Reading Truck Equipment added this a quality inspection item on 09/05/2020 with a requirment to take photographs of as-built equipment. The information contained in this report was submitted pursuant to 49 CFR ยง573 Part 573 Safety Recall Report 24V-222
Page 3
The information contained in this report was submitted pursuant to 49 CFR ยง573
Recall Schedule :
Description of Recall Schedule : NR
Planned Dealer Notification Date : MAR 29, 2024 – APR 15, 2024
Planned Owner Notification Date : MAR 29, 2024 – APR 15, 2024
Purchaser Information :
The following manufacturers purchased this defective/noncompliant equipment for possible use or installation in new motor vehicles or new items of motor vehicle equipment:
Name : Address :
Country : Company Phone :
* NR – Not Reported
**************************************************************************************************************
**************************************************************************************************************
**************************************************************************************************************
**************************************************************************************************************
**************************************************************************************************************
SEOCONTENT-END