โThis site contains affiliate links for which OEMDTC may be compensatedโ |
May 18, 2023 NHTSA CAMPAIGN NUMBER: 23V356000
Electrical Short-Circuit in Fuse Box
An electrical short-circuit can increase the risk of a fire.
NHTSA Campaign Number: 23V356
Manufacturer Gillig, LLC
Components ELECTRICAL SYSTEM
Potential Number of Units Affected 50
Summary
Gillig, LLC (Gillig
) is recalling certain 2022 Low Floor CNG transit buses. An electrical failure may cause a short-circuit in the fuse box mounted underneath the driver’s seat platform.
Remedy
Gillig will provide new busbars, free of charge. The manufacturer has not yet provided a schedule for recall notification. Owners may contact Gillig
customer service at 1-510-264-5073 or 1-800-735-1500.
Notes
Owners may also contact the National Highway Traffic Safety Administration Vehicle Safety Hotline at 1-888-327-4236 (TTY 1-800-424-9153), or go to www.nhtsa.gov.
Chronology :
On April 13 2023 during manufacturing, an incomplete vehicle experienced an electrical failure in the fuse box mounted underneath the driverโs platform.
Between April 14 and April 22, GILLIG conducted an internal analysis to determine the nature of the issue and whether the same event could potentially affect other vehicles. The early findings pointed towards a possible electrical short caused by contact between the 24V busbar and the metal fuse box. Meanwhile, on April 20, out of an abundance of caution, the vehicle customer identified as potentially affected, decided to ground the entire suspect fleet.
On April 24 GILLIG engineering confirmed the initial observation and determined the issue may be caused by a custom redesign of the low-voltage disconnect switch which may cause excessive preload and subsequent damage of the rubber insulation grommets of the fuse box.
On April 26 GILLIG completed safety analysis and confirmed the failure mode may potentially affect a limited population of vehicles owned by the customer initially identified.
On May 11 the GILLIG Safety Committee decided to file a formal safety recall with NHTSA.
As of May 16 2023, GILLIG is not aware of any other similar event nor injuries potentially related to this condition.
1 Affected Product
Vehicle
MAKE | MODEL | YEAR |
GILLIG![]() | LOW FLOOR | 2022 |
4 Associated Documents
Defect Notice 573 Report
RCLRPT-23V356-2217.PDF 215.708KB
Recall Acknowledgement
RCAK-23V356-5554.pdf 645.401KB
Recall 573 Report – 5/23/2023
RCLRPT-23V356-4791.PDF 215.798KB
Recall 573 Report – 5/30/2023
RCLRPT-23V356-7288.PDF 215.799KB
Latest Recalls Documents
- Upgrade & Thicken: A pair of 12V power distribution block, includes a red and a black power distribution block(Positive&Negative). Our 12V Bus Bar also features 4MM Thicker Copper Bus Bar Plate which can be connected to wider range of cables
- 250A Rating: The power distribution block bus bar rated 250A when work in 12v circuit, and the battery terminal block can handle MAX 48V
- 3/8" Stud: The battery bus bar terminal block includes 4 x 3/8" studs terminal and 3 x #8 screw terminals, which makes the 12V junction block able to accept large size terminal connectors and wires. The nylon bottom is also secured by M10 post which makes it more fixed and won't strip
- Protect Cover and Nuts: Each power busbar will come with a protect cover and two nuts, which helps to shelter as much exposed area as possible to reduce the risks of accidental contact and prevent short circuit, makes the circuit safer
- Wide Application: The 12 volt buss bar with cover aims to make the wiring of circuit become neat and tidy, preventing mess harness from causing electric short circuit, it is suitable for automotive, car, truck, marine, boat, solar wiring
- Heavy Duty: This 12V bus bar can handle max operating voltage 48V DC , max continuous amperage: 150A
- Unique Design: 12 stainless M4 terminal screws, 1 x 1/4" (M6) terminal stud & nut for easy installation and route your wires with minimal effort
- What You Get: 1 x positive 12 volt bus bar, 1 x ground 12 volt bus bar, 2 x covers, 2 x 2 AWG 1/4" copper lug and 24 x terminals
- Product Advantage: Thick tinned copper plate busbar, base is made of high quality ABS
material, which is mechanically strong, insulated, heat resistant and flame resistant, durable made for safety use
- Wide Application: Using the battery bus bar for wiring can keep the circuit neat and tidy, reducing the possibility of short circuit. Suitable for car, caravan, boat, yacht, solar system, etc
- Material: The bus bar is composed of brass bottom plate and 304 stainless steel screw terminals, which is not easy to rust; The protective sleeve and base are made of nylon, which is flame retardant, can prevent electrical short circuit and is safer
- Product features: 3mm copper busbar is thicker than other 2.0mm brass busbars and can withstand 250A actual current; The bus bar is very firm and will not fall off, and the exposed areas on both sides allow 180 installation
- Parameter: Maximum voltage: 300V AC, 48V DC, and maximum current: 250A
- Scope of application: Using battery bus bars for wire management and wiring can make circuit wiring neat and prevent electrical short circuit; Widely used in automobiles, automobiles, trucks, ships, boats, yachts, etc
- Packaging: One red terminal: 4 x 3/8 inch (M10) with screws: 6x#8 battery bus bar, one black terminal: 4 x 3/8 inch (M10) with screws: 6x#8 battery bus bar
- PREMIUM QUALITY --- Made of environment fire-resist PBT material, this fuse box meets all the standards of an ideal fuse block. It is mechanically strong, insulated, heat resistant and flame resistant. There will hardly cause any issue like produce fracture, deformation, combustion or short circuit phenomenon
- LED WARNING INDICATOR --- Red LED warning light on fuse box will light up immediately when the corresponding fuse is blown. It is both safe and easy for you to check and replace the blown fuse
- EASY TO SET UP --- No need to worry about getting your fuse box ready to use. This 6 circuit fuse box is very easy to install. Make your wiring clean
- PERFECT FOR YOUR VEHICLE --- This premium fuse box with bus bar is essential for all vehicles with a 10-32 Volt DC power source so you can use it on every car or boat
- Free Blade Fuses --- 6-Way fuse box Package includes: 4x 20A Fuse, 4x 15A Fuse,2x 10A Fuse, 2x 5A Fuse, 2x Labels, 4x Screws
- The biggest difference: Ours' bottom is buckle design, not easy to fall off; Others' bottom no buckle design, easy to fall off; Inverted buckle design can snap the protective cover over the terminals firmly
- Features: Aienxn 12v battery bus bar includes 1 x 1/4" (M6) stud & nut, 12 x M4 (#8) terminals, which is easy for installation and route your wires with minimal effort. The bolt goes through from bottom to top, which makes the structure more firm
- Wide Application: Using battery bus bars for wiring can keep the circuit clean and reduce the possibility of short circuit; It is suitable for automotive, marine, boat, car, etc
- Package Include: Each battery bus bar 12v includes two power bus bars in the package - one positive bus bar and one ground bus bar; You will also get 2pcs silicone terminal covers, 2pcs copper lugs and 24pcs ring terminals
- Current: This battery distribution block can handle max operating voltage 48V DC, max continuous amperage: 150A
- ใProduct Nameใ- Bus bar terminal block 12v, these battery bus bar 12v will come in pairs, includes one positive bus bar (red) and one ground bus bar (black).
- ใ300A M10 Stud Busbarใ- This battery distribution block can handle max 300A continuous amperage at Max 300V AC or 48V DC voltage. Each battery terminal block includes - 6 x M10 (3/8")terminal studs.
- ใRound Corner Baseใ - This 12v bus bar is unique round corner base design, which makes the marine bus bar unique and special, looks more extraordinary compared with others.
- ใSpecial Design Coverใ - The exposed area of two side of this 12v power distribution block cover allows 180ยฐ wire lug installation, can meet a variety kinds of install methods of end terminals.
- ใApplicationใ - This 300A bus bar will have better performance in high current systems. The package includes one positive and one ground distribution block, suitable for automotive, car, marine boat, etc.
- Rating: The bus bar rated 250A when works in 12v supplier circuit, and the battery busbar can handle MAX 48v source power
- 5/16" Stud: The battery bus bar terminal block includes 3 x 5/16"(M8) studs and 10 x #8 screw terminals, which makes the 12v bus bar be able to accept large size terminal connectors and wires
- What You Get: A pair of 12v power distribution block, includes a positive power distribution block and a negative power distribution block, 4 x Mounting Screws, 2 x 1AWG 5/16" Copper Lugs, 4 x 6AWG 5/16" Copper Lugs, 20 x Terminals
- Protect Cover & Nuts: Each power bus bar will come with a protect cover and two nuts, which helps to shelter as much exposed area as possible to reudeces the risks of accidental contact and prevent short circuit, makes the circuit safer
- Wide Application: The 12 volt bus bar with cover aims to make the wiring of circuit become neat and tidy, preventing mess harness from causing electric short circuit, suitable for automotive, car, truck, marine, boat, solar wiring
- Heavy Duty: This 12V bus bar can handle voltage max 48V DC and continuous current max 250A
- Product Information: Each 250A power distribution block contains 2 x 3/8" (M10) studs. All the studs on our busbars are made of 304 stainless steel to protect against corrosion
- What You Get: 1 x positive 12 volt bus bar, 1 x ground 12 volt bus bar, 2 x 1/0 AWG copper lug and 4 x 6 AWG copper lug
- Protective Cover: The marine bus bar comes with a protective cover made of tough polycarbonate plastic for excellent strength and durability, preventing short circuits and making the circuit safer
- Wide Application: Using the battery bus bar for wiring can keep the circuit neat and tidy, reducing the possibility of short circuit. Suitable for car, caravan, boat, yacht, solar system, etc
- ใProduct Nameใ- Battery bus bar terminal block, these busbars will come in pairs, include one positive bus bar (red one) and one negative bus bar (black one).
- ใTerminals & Ratingใ- Each 12v power distribution block includes - 6 x M8 (5/16") terminal studs. This battery distribution block can handle voltage @ Max 300V AC, 48V DC, and continous amperage @ Max 130A AC, 150A DC.
- ใRound Corner Baseใ - The 12 volt bus bar is unique round corner base design, which makes the battery terminal block unique and special, looks more extraordinary compared with other busbars.
- ใMore Open Area Design Coverใ - The cover of this 12v power block will allow 180ยฐ wire lug installation and can meet variety kinds of installat methods of end terminals.
- ใApplicationใ - This marine power distribution block uses copper plates and stainless steel terminals as conductors, which enables the battery distribution block to work in extreme environment, suitable for automotive, car, marine, boat, etc.
- Robust Terminals & Electrical Ratings: Each busbars 12 volt features 6 x 5/16" (M8) terminal studs. And this power distribution block is capable of handling up to 48V DC, with maximum current 250A
- Unique Round Corner Base Design: The 12V bus bar includes a distinctive round corner base, enhancing both aesthetic appeal and stability of our 12v power distribution block, setting it apart from standard bus bars.
- More Open Area Cover Design: The cover of our battery distribution block allows for 180ยฐ wire lug installation, supporting various connection methods, which increases installation flexibility for users.
- Suitable for Extreme Environments: Constructed with copper plates and stainless steel terminals as conductors, this 12v distribution block is designed to perform reliably in harsh conditions, making it ideal for automotive, marine, and other demanding applications.
- Efficient Power Distribution Design: This battery bus bar terminal block 12v comes in pairs, including one positive (red) and one negative (black) bus bar. Also, it is equipped with 12 copper ring lugs and 12 heat shrink tubes for your need, designed for efficient power distribution.
SEOCONTENT-START
OMB Control No.: 2127-0004 Part 573 Safety Recall Report 23V-356 The information contained in this report was submitted pursuant to 49 CFR ยง573 Manufacturer Name : Gillig, LLC Submission Date : MAY 18, 2023 NHTSA Recall No. : 23V-356 Manufacturer Recall No. : NR Manufacturer Information : Manufacturer Name : Gillig
, LLC Address : 451 Discovery Drive LIVERMORE CA 94551 Company phone : 1-800-735-1500 Population : Number of potentially involved : 50 Estimated percentage with defect : 100 % Vehicle Information : Vehicle 1 : 2022-2022 GILLIG
LOW FLOOR CNG Vehicle Type : BUSES, MEDIUM & HEAVY VEHICLES Body Style : ALL Power Train : CNG/LPG Descriptive Information : Metal-to-metal contact may cause an electrical short in the vehicle fuse box. Production Dates : AUG 10, 2022 – DEC 01, 2022 VIN Range 1 : Begin : 15GGD3115N3196740 End : 15GGD3112N3196789 โ Not sequential Description of Defect : Description of the Defect : GILLIG
has determined that a limited population of CNG vehicles is affected by a defect that may cause an electrical failure in the fuse box mounted underneath the driverโs platform. The insulation of the red 24V busbar may become compromised due to excessive preload pinching the rubber grommet between the copper busbar and the steel fuse box. The resulting electrical short may cause a thermal event thus increasing the risk of vehicle fire. As a result of the above, GILLIG
has decided to voluntarily initiate a safety recall campaign for the vehicle population that may be affected by the issue. Only one customer is affected by this recall. FMVSS 1 : NR FMVSS 2 : NR Description of the Safety Risk : A thermal event with increased risk of vehicle fire Description of the Cause : NR Identification of Any Warning that can Occur : GILLIG
is not aware of any driverโs warning prior to failure. Involved Components : Part 573 Safety Recall Report 23V-356 Page 2 The information contained in this report was submitted pursuant to 49 CFR ยง573 Component Name 1 : NR Component Description : NR Component Part Number : NR Supplier Identification : Component Manufacturer Name : NR Address : NR NR Country : NR Chronology : On April 13 2023 during manufacturing, an incomplete vehicle experienced an electrical failure in the fuse box mounted underneath the driverโs platform. Between April 14 and April 22, GILLIG
conducted an internal analysis to determine the nature of the issue and whether the same event could potentially affect other vehicles. The early findings pointed towards a possible electrical short caused by contact between the 24V busbar and the metal fuse box. Meanwhile, on April 20, out of an abundance of caution, the vehicle customer identified as potentially affected, decided to ground the entire suspect fleet. On April 24 GILLIG
engineering confirmed the initial observation and determined the issue may be caused by a custom redesign of the low-voltage disconnect switch which may cause excessive preload and subsequent damage of the rubber insulation grommets of the fuse box. On April 26 GILLIG
completed safety analysis and confirmed the failure mode may potentially affect a limited population of vehicles owned by the customer initially identified. On May 11 the GILLIG
Safety Committee decided to file a formal safety recall with NHTSA. As of May 16 2023, GILLIG
is not aware of any other similar event nor injuries potentially related to this condition. Part 573 Safety Recall Report 23V-356 Page 3 The information contained in this report was submitted pursuant to 49 CFR ยง573 Description of Remedy : Description of Remedy Program : The remedy consists of a redesign of the 12 and 24V busbars that eliminates excessive pinch of the rubber grommets and ensures appropriate electrical isolation. Pursuant to 49 CFR 577.11(e), GILLIG
requests that it be exempt from providing notification of a reimbursement plan. Any pre-notification product failure would have been addressed under the manufacturerโs limited warranty. Accordingly, no person would be eligible for reimbursement pursuant to 573.13. How Remedy Component Differs from Recalled Component : New 12V and 24V busbar parts. Identify How/When Recall Condition was Corrected in Production : All current production buses with a similar low-voltage disconnect design will be updated with the new parts. Recall Schedule : Description of Recall Schedule : GILLIG
plans to send out the ownerโs notification letters by the end of the 60-day period from the date this recall is filed. GILLIG
does not have a dealer network and, therefore, a dealerโs notification is not required. Planned Dealer Notification Date : NR – NR Planned Owner Notification Date : NR – NR * NR – Not Reported
**************************************************************************************************************
OMB Control No.: 2127-0004 Part 573 Safety Recall Report 23V-356 The information contained in this report was submitted pursuant to 49 CFR ยง573 Manufacturer Name : Gillig, LLC Submission Date : MAY 30, 2023 NHTSA Recall No. : 23V-356 Manufacturer Recall No. : NR Manufacturer Information : Manufacturer Name : Gillig
, LLC Address : 451 Discovery Drive LIVERMORE CA 94551 Company phone : 1-800-735-1500 Population : Number of potentially involved : 30 Estimated percentage with defect : 100 % Vehicle Information : Vehicle 1 : 2022-2022 GILLIG
LOW FLOOR CNG Vehicle Type : BUSES, MEDIUM & HEAVY VEHICLES Body Style : ALL Power Train : CNG/LPG Descriptive Information : Metal-to-metal contact may cause an electrical short in the vehicle fuse box. Production Dates : AUG 10, 2022 – DEC 01, 2022 VIN Range 1 : Begin : 15GGD3115N3196740 End : 15GGD3112N3196789 โ Not sequential Description of Defect : Description of the Defect : GILLIG
has determined that a limited population of CNG vehicles is affected by a defect that may cause an electrical failure in the fuse box mounted underneath the driverโs platform. The insulation of the red 24V busbar may become compromised due to excessive preload pinching the rubber grommet between the copper busbar and the steel fuse box. The resulting electrical short may cause a thermal event thus increasing the risk of vehicle fire. As a result of the above, GILLIG
has decided to voluntarily initiate a safety recall campaign for the vehicle population that may be affected by the issue. Only one customer is affected by this recall. FMVSS 1 : NR FMVSS 2 : NR Description of the Safety Risk : A thermal event with increased risk of vehicle fire Description of the Cause : NR Identification of Any Warning that can Occur : GILLIG
is not aware of any driverโs warning prior to failure. Involved Components : Part 573 Safety Recall Report 23V-356 Page 2 The information contained in this report was submitted pursuant to 49 CFR ยง573 Component Name 1 : Busbar Component Description : Low-voltage 12V busbar Component Part Number : 13-57847-013 Component Name 2 : Busbar Component Description : Low-voltage 24V busbar Component Part Number : 13-57847-012 Supplier Identification : Component Manufacturer Name : NR Address : NR NR Country : NR Chronology : On April 13 2023 during manufacturing, an incomplete vehicle experienced an electrical failure in the fuse box mounted underneath the driverโs platform. Between April 14 and April 22, GILLIG
conducted an internal analysis to determine the nature of the issue and whether the same event could potentially affect other vehicles. The early findings pointed towards a possible electrical short caused by contact between the 24V busbar and the metal fuse box. Meanwhile, on April 20, out of an abundance of caution, the vehicle customer identified as potentially affected, decided to ground the entire suspect fleet. On April 24 GILLIG
engineering confirmed the initial observation and determined the issue may be caused by a custom redesign of the low-voltage disconnect switch which may cause excessive preload and subsequent damage of the rubber insulation grommets of the fuse box. On April 26 GILLIG
completed safety analysis and confirmed the failure mode may potentially affect a limited population of vehicles owned by the customer initially identified. On May 11 the GILLIG
Safety Committee decided to file a formal safety recall with NHTSA. As of May 16 2023, GILLIG
is not aware of any other similar event nor injuries potentially related to this condition. Part 573 Safety Recall Report 23V-356 Page 3 The information contained in this report was submitted pursuant to 49 CFR ยง573 Description of Remedy : Description of Remedy Program : The remedy consists of a redesign of the 12 and 24V busbars that eliminates excessive pinch of the rubber grommets and ensures appropriate electrical isolation. Pursuant to 49 CFR 577.11(e), GILLIG
requests that it be exempt from providing notification of a reimbursement plan. Any pre-notification product failure would have been addressed under the manufacturerโs limited warranty. Accordingly, no person would be eligible for reimbursement pursuant to 573.13. How Remedy Component Differs from Recalled Component : New 12V and 24V busbar parts. Identify How/When Recall Condition was Corrected in Production : All current production buses with a similar low-voltage disconnect design will be updated with the new parts. Recall Schedule : Description of Recall Schedule : GILLIG
plans to send out the ownerโs notification letters by the end of the 60-day period from the date this recall is filed. GILLIG
does not have a dealer network and, therefore, a dealerโs notification is not required. Planned Dealer Notification Date : NR – NR Planned Owner Notification Date : NR – NR * NR – Not Reported
**************************************************************************************************************
OMB Control No.: 2127-0004 Part 573 Safety Recall Report 23V-356 The information contained in this report was submitted pursuant to 49 CFR ยง573 Manufacturer Name : Gillig, LLC Submission Date : MAY 23, 2023 NHTSA Recall No. : 23V-356 Manufacturer Recall No. : NR Manufacturer Information : Manufacturer Name : Gillig
, LLC Address : 451 Discovery Drive LIVERMORE CA 94551 Company phone : 1-800-735-1500 Population : Number of potentially involved : 50 Estimated percentage with defect : 100 % Vehicle Information : Vehicle 1 : 2022-2022 GILLIG
LOW FLOOR CNG Vehicle Type : BUSES, MEDIUM & HEAVY VEHICLES Body Style : ALL Power Train : CNG/LPG Descriptive Information : Metal-to-metal contact may cause an electrical short in the vehicle fuse box. Production Dates : AUG 10, 2022 – DEC 01, 2022 VIN Range 1 : Begin : 15GGD3115N3196740 End : 15GGD3112N3196789 โ Not sequential Description of Defect : Description of the Defect : GILLIG
has determined that a limited population of CNG vehicles is affected by a defect that may cause an electrical failure in the fuse box mounted underneath the driverโs platform. The insulation of the red 24V busbar may become compromised due to excessive preload pinching the rubber grommet between the copper busbar and the steel fuse box. The resulting electrical short may cause a thermal event thus increasing the risk of vehicle fire. As a result of the above, GILLIG
has decided to voluntarily initiate a safety recall campaign for the vehicle population that may be affected by the issue. Only one customer is affected by this recall. FMVSS 1 : NR FMVSS 2 : NR Description of the Safety Risk : A thermal event with increased risk of vehicle fire Description of the Cause : NR Identification of Any Warning that can Occur : GILLIG
is not aware of any driverโs warning prior to failure. Involved Components : Part 573 Safety Recall Report 23V-356 Page 2 The information contained in this report was submitted pursuant to 49 CFR ยง573 Component Name 1 : Busbar Component Description : Low-voltage 12V busbar Component Part Number : 13-57847-013 Component Name 2 : Busbar Component Description : Low-voltage 24V busbar Component Part Number : 13-57847-012 Supplier Identification : Component Manufacturer Name : NR Address : NR NR Country : NR Chronology : On April 13 2023 during manufacturing, an incomplete vehicle experienced an electrical failure in the fuse box mounted underneath the driverโs platform. Between April 14 and April 22, GILLIG
conducted an internal analysis to determine the nature of the issue and whether the same event could potentially affect other vehicles. The early findings pointed towards a possible electrical short caused by contact between the 24V busbar and the metal fuse box. Meanwhile, on April 20, out of an abundance of caution, the vehicle customer identified as potentially affected, decided to ground the entire suspect fleet. On April 24 GILLIG
engineering confirmed the initial observation and determined the issue may be caused by a custom redesign of the low-voltage disconnect switch which may cause excessive preload and subsequent damage of the rubber insulation grommets of the fuse box. On April 26 GILLIG
completed safety analysis and confirmed the failure mode may potentially affect a limited population of vehicles owned by the customer initially identified. On May 11 the GILLIG
Safety Committee decided to file a formal safety recall with NHTSA. As of May 16 2023, GILLIG
is not aware of any other similar event nor injuries potentially related to this condition. Part 573 Safety Recall Report 23V-356 Page 3 The information contained in this report was submitted pursuant to 49 CFR ยง573 Description of Remedy : Description of Remedy Program : The remedy consists of a redesign of the 12 and 24V busbars that eliminates excessive pinch of the rubber grommets and ensures appropriate electrical isolation. Pursuant to 49 CFR 577.11(e), GILLIG
requests that it be exempt from providing notification of a reimbursement plan. Any pre-notification product failure would have been addressed under the manufacturerโs limited warranty. Accordingly, no person would be eligible for reimbursement pursuant to 573.13. How Remedy Component Differs from Recalled Component : New 12V and 24V busbar parts. Identify How/When Recall Condition was Corrected in Production : All current production buses with a similar low-voltage disconnect design will be updated with the new parts. Recall Schedule : Description of Recall Schedule : GILLIG
plans to send out the ownerโs notification letters by the end of the 60-day period from the date this recall is filed. GILLIG
does not have a dealer network and, therefore, a dealerโs notification is not required. Planned Dealer Notification Date : NR – NR Planned Owner Notification Date : NR – NR * NR – Not Reported
**************************************************************************************************************
**************************************************************************************************************
SEOCONTENT-END
Last update on 2025-04-17 / Affiliate links / Images from Amazon Product Advertising API
This product presentation was made with AAWP plugin.