June 22, 2023 NHTSA CAMPAIGN NUMBER: 23V438000
Boom Tip Outlet May Be Missing GFCI Protection
An outlet without GFCI protection may fail to shut off electrical power when a ground-fault occurs, increasing the risk of injury or fire.
NHTSA Campaign Number: 23V438
Manufacturer Altec Industries, Inc.
Components ELECTRICAL SYSTEM
Potential Number of Units Affected 18
Summary
Altec Industries, Inc. (Altec) is recalling certain 2019-2022 AT335 vehicles. An inverter-powered outlet may have been installed at the aerial boom tip without ground-fault interrupter (GFCI) protection.
Remedy
Dealers will inspect and install a GFCI outlet as necessary, free of charge. Owner notification letters are expected to be mailed August 25, 2023. Owners may contact Altec’s customer service at 1-877-462-5832. Altec’s number for this recall is CSN 3091.
Notes
Owners may also contact the National Highway Traffic Safety Administration Vehicle Safety Hotline at 1-888-327-4236 (TTY 1-800-424-9153), or go to www.nhtsa.gov.
Chronology :
In December 2022, Altec initiated a review of compliance with a revision to an internal standard and discovered engineering might not have revised some unit design specifications to ensure they complied with the new requirements. On March 28, 2023, an investigation was initiated to determine if units in the field could have a 110V outlet at the boom tip without an inline GFCI mounted in the body compartment. On June 16, 2023, after reviewing the data collected in the investigation, Altec determined that a defect could exist on units in the field, and a campaign should be completed to inspect and update the affected units. There were no warranty claims or field reports identified. There have been no accidents, injuries, or deaths related to this issue.
4 Affected Products
Vehicle
| MAKE | MODEL | YEAR |
| ALTEC | AERIAL DEVICE | 2019-2022 |
2 Associated Documents
Recall Acknowledgement
RCAK-23V438-2753.pdf 646.236KB
Defect Notice 573 Report
RCLRPT-23V438-2794.PDF 213.619KB
Latest Recalls Documents
- 15 amp Non-Tamper Resistant Ground Fault Circuit Interrupter (GFCI) outlet receptacle for indoor use. Please kindly check if the depth of electrical box can fit our GFCI outlets before purchasing.
- The indicator light will turn On GREEN once the power is ON. Press the RESET button to restore power to the GFCI outlet. The LED indicator keeps GREEN no matter you press the RESET or TEST button.
- The ETL certification is a sign of a better quality product. This product has gone through many test procedures before getting its approval which makes it the safest GFCI.
- Back and side wired for easy installation. Decorator wall plate and screws included. Caution: Do not unscrew the terminal screws too far or with excessive force. Do not use power tools to loosen the terminal screws.
- 15A/125V/1875W. Wallplate Included, ETL Listed
- 20 amp Non-Tamper Resistant Ground Fault Circuit Interrupter (GFCI) outlet receptacle for indoor use. 20A/125V/2500W. Please kindly check if the depth of electrical box can fit our GFCI outlets before purchasing.
- Ultra slim design profile easily fits in electrical box and wall plate. Easy Installation with back or side wiring. Standard wall plate, screws and installation instructions included.
- The ETL certification is a sign of a better quality product. This product has gone through many test procedures before getting its approval which makes it the safest GFCI.
- The indicator light will turn on GREEN once the power is ON. Press the RESET button to restore power to the GFCI outlet. When you press the RESET button, the indicator light turns GREEN; when you press the TEST button, the indicator light turns off.
- 20A/125V/2500W. Wallplate Included, ETL Listed. Caution: Do not unscrew the terminal screws too far or with excessive force. Do not use power tools to loosen the terminal screws.
- Designed to improve immunity for reduced High Frequency (HF) nuisance tripping. providing increased compatibility with appliances and other electronics
- For an added layer of protection, the GFCI regularly conducts an automatic internal test to confirm that it can respond to a ground fault
- Provides continuous ground fault protection - detects and trips on actual ground fault even when self-test is being conducted
- Status indicator light provides simple, intuitive feedback on power and protection status as well as indication of line/load reversal
- Patented lockout action prevents reset if GFCI is damaged and cannot respond to a ground fault
- Certified Safety with US Patent Protection. This GFCI outlet is UL 943 & UL 498 Certified, Class A Rated, ensuring the highest level of ground fault protection. With a 20A/125V/60Hz rating, it’s perfect for both residential and commercial use. Additionally, its US Patent Protected design guarantees unmatched reliability and safety.
- Smart LED for Real-Time Status Monitoring. Featuring a Multi-State LED Display, this outlet provides clear indicators for self-test status, normal operation, fault warnings, and end-of-life alerts. The integrated Test & Reset Buttons allow users to easily check wiring correctness and ensure proper functionality, making it a user-friendly and safety-focused choice.
- Tamper-Resistant and Weather-Resistant Design. Designed with TR & WR Ratings, this outlet protects children from electrical hazards and performs reliably in harsh environments. It has passed the UL Salt Spray Test, ensuring corrosion resistance for outdoor, bathroom, and kitchen use. With an operating range of -30°F to 150°F and up to 95% humidity, it’s built for durability in any condition.
- Advanced Chip for Enhanced Performance. Equipped with an Advanced Chip, this GFCI outlet delivers superior stability, fewer false trips, and faster response times. It detects ground faults at a threshold of less than 6mA and cuts power in under 25ms, providing reliable and efficient protection for your home or workplace.
- Premium Materials for Long-Lasting Reliability. Built with 0.81mm Thick Copper and 0.4mm Silver-Plated Contacts, this outlet ensures efficient current transmission and reduced heat buildup. Its robust construction minimizes plug failure and enhances durability, making it a safer and more reliable choice for everyday use.
- Designed to improve immunity for reduced High Frequency (HF) nuisance tripping. providing increased compatibility with appliances and other electronics
- Continuously protects against electric shock & electrocution by interrupting power if a ground-fault is detected
- Required by the NEC for areas around the home within a close proximity to a water source (kitchen, bathroom, laundry room, basement, garage/carport, pool area)
- Patented reset/lockout feature prevents reset if the GFCI is unable to respond to a ground-fault or if it isn't wired properly. Regularly conducts an automatic self-test to ensure safety
- LED indicator provides simple, intuitive feedback on power and protection status
SEOCONTENT-START
OMB Control No.: 2127-0004 Part 573 Safety Recall Report 23V-438 The information contained in this report was submitted pursuant to 49 CFR §573 Manufacturer Name : Altec Industries, Inc. Submission Date : JUN 22, 2023 NHTSA Recall No. : 23V-438 Manufacturer Recall No. : CSN 3091 Manufacturer Information : Manufacturer Name : Altec Industries, Inc. Address : 210 Inverness Center Drive Birmingham AL 35242 Company phone : 205 991 7733 Population : Number of potentially involved : 18 Estimated percentage with defect : 100 % Vehicle Information : Vehicle 1 : 2019-2022 Altec AT335 Vehicle Type : Body Style : Power Train : NR Descriptive Information : The recall population was determined from a review of production records. Production Dates : APR 05, 2019 – DEC 28, 2022 VIN Range 1 : Begin : NR End : NR Not sequential Description of Defect : Description of the Defect : An inverter-powered outlet might have been installed at the aerial boomtip without GFCI protection. FMVSS 1 : NR FMVSS 2 : NR Description of the Safety Risk : If the 110V outlet at the boom tip does not have GFCI protection, the lack of circuit protection increases the risk of severe electric shock or thermal events in moist environments. Description of the Cause : NR Identification of Any Warning that can Occur : There is no warning. Involved Components : Part 573 Safety Recall Report 23V-438 Page 2 The information contained in this report was submitted pursuant to 49 CFR §573 Component Name 1 : NA Component Description : NR Component Part Number : NR Supplier Identification : Component Manufacturer Name : Altec Inc. Address : 2106 S Riverside Rd Saint Joseph Missouri 64507-2535 Country : United States Chronology : In December 2022, Altec initiated a review of compliance with a revision to an internal standard and discovered engineering might not have revised some unit design specifications to ensure they complied with the new requirements. On March 28, 2023, an investigation was initiated to determine if units in the field could have a 110V outlet at the boom tip without an inline GFCI mounted in the body compartment. On June 16, 2023, after reviewing the data collected in the investigation, Altec determined that a defect could exist on units in the field, and a campaign should be completed to inspect and update the affected units. There were no warranty claims or field reports identified. There have been no accidents, injuries, or deaths related to this issue. Description of Remedy : Description of Remedy Program : The remedy will include an inspection for a GFCI outlet located in the body compartment that houses the inverter between the inverter and the boomtip outlet. If there is no GFCI outlet inline, a GFCI outlet will be added. The recall remedy will be completed free of charge when presented for repair. The Altec Warranty Policy covers the recall remedy, including cases requiring reimbursement for the cost of obtaining a pre-notification remedy of the problem associated with this recall. How Remedy Component Differs from Recalled Component : The remedy adds a GFCI outlet for the boomtip outlet circuit in a body compartment. Identify How/When Recall Condition was Corrected in Production : On December 19, 2022, production documents were updated to specify that a GFCI be installed in the body compartment for the boomtip outlet circuit. Part 573 Safety Recall Report 23V-438 Page 3 The information contained in this report was submitted pursuant to 49 CFR §573 Recall Schedule : Description of Recall Schedule : Altec will issue CSN 3091 to the owners of the affected units. Altec does not have a dealer network and issues letters to owners only. Planned Dealer Notification Date : AUG 25, 2023 – AUG 25, 2023 Planned Owner Notification Date : AUG 25, 2023 – AUG 25, 2023 * NR – Not Reported
**************************************************************************************************************
**************************************************************************************************************
**************************************************************************************************************
**************************************************************************************************************
SEOCONTENT-END
This product presentation was made with AAWP plugin.