April 16, 2019 NHTSA CAMPAIGN NUMBER: 19V306000
Generator Exhaust Pipe may get Damaged
If motorhome is driven on an incline, the generator exhaust pipe may get damaged, possibly resulting in carbon monoxide entering the vehicle when the generator is running, increasing the risk of injury or death.
NHTSA Campaign Number: 19V306
Manufacturer REV Recreation Group
Components EQUIPMENT
Potential Number of Units Affected 62
Summary
REV Recreation Group (REV) is recalling certain 2019 Fleetwood Flair and Holiday Rambler
Admiral motorhomes. The generator exhaust pipe placement exits the motorhome within the vehicle’s departure angle.
Remedy
REV has notified owners, and dealers will inspect and reroute the generator exhaust pipe, as necessary, free of charge. The recall began May 21, 2019. Owners may contact REV customer service at 1-800-509-3417. REV’s number for this recall is 190412REV.
Notes
Owners may also contact the National Highway Traffic Safety Administration Vehicle Safety Hotline at 1-888-327-4236 (TTY 1-800-424-9153), or go to www.safercar.gov.
Revised 05/22/2019 – corrected affected unit list
Recall Bulletin 190412REV
RECALL BULLETIN:
190412REV
YEAR(S) AFFECTED:
2019
PRODUCT(S) AFFECTED:
Fleetwood Flair Model 32 S only Manufactured 6/20/2018 through 2/22/2019
Holiday Rambler
Model 32 S only
Admiral Manufactured 6/29/2018 through 3/22/2019
MODEL(S) AFFECTED:
32 S Only
SUBJECT:
Inspection / Correction of Generator Exhaust Pipe Routing
KEYWORDS:
ISSUE DATE:
May 2019
The purpose of this Recall Service Bulletin is to inform all REV Recreation Group dealers about the need to inspect the generator exhaust pipe routing on certain model year 2019 Fleetwood Flair Model 32 S, and certain model year 2019 Holiday Rambler
Admiral Model 32 S, to ensure the exhaust pipe does not intrude into the departure angle of the coach. If the generator exhaust pipe is improperly routed, it will need to be replaced with a different exhaust pipe that exits at the rear of the vehicle.
The lists of affected motorhomes and required replacement parts appear at the end of this Bulletin.
CONDITION:
On motorhomes affected by this recall, the generator exhaust pipe may be routed in a manner that causes it to intrude into the departure angle of the coach. This improper mounting location could cause the generator exhaust pipe to become damaged or sheared off when the vehicle is driven on an incline, potentially allowing carbon monoxide from generator exhaust emissions to enter the vehicle, which could result in illness or death.
PROCEDURES:
Dealers are required to call REV Dealer Technical Support to obtain Prior Authorization before beginning any work and after the unit is in their bay. You will receive instructions and will be provided any necessary part ordering information.
Fleetwood Dealer Technical Support: (800) 816-9825
Holiday Rambler
Dealer Technical Support: (877) 332-9239
- READ THIS ENTIRE BULLETIN CAREFULLY BEFORE PROCEEDING AND FOLLOW ALL SAFETY PRECAUTIONS.
- Review the list of affected units at the end of this bulletin to ensure the motorhome you are inspecting is part of this campaign.
- Take a copy of this bulletin with you when servicing the unit.
- PHOTOS WILL BE REQUIRED FOR THE FOLLOWING PROCEDURES. READ PHOTO REQUIREMENTS CAREFULLY. INSUFFICIENT PHOTO DOCUMENTATION MAY RESULT IN CLAIM DENIAL
- If there are any questions after reviewing the entire procedure, contact REV Dealer Technical Support.
| WARNING |
|
INSPECTION
NOTE: This document only applies to the Flair/Admiral 32 S; no other models are affected.
1. Park the motorhome on dry, level pavement. Place the transmission into PARK and set the parking brake. Turn off the ignition and remove the ignition key. Maintain control of keys while work is performed.
2. Turn off the ignition and remove the ignition key. Maintain control of the ignition key until all repairs are completed. Attach a notice, “Do Not Use”, to the generator switch in order to prevent activation of the system.
3. Block wheels to prevent movement.
4. At the driver’s side, rear of the coach, locate the generator exhaust pipe and determine whether it exits on the side of the motorhome or out the rear, under the bumper. See Figures 1 & 2 for both examples of exhaust pipe routing.
a) If the generator exhaust pipe exits the motorhome at the rear of the coach under the bumper, take several clear photos (see Photo Requirements on Page 3) and submit a claim using code 6080-11, “Inspected/Not Defective”; no more work is required.
b) If the generator exhaust pipe exits on the side of the motorhome, take several clear photos (see Photo Requirements on Page 3) and then proceed to the Repair Procedure beginning at Step 5.
Photo Requirements:
For Non-Defective Units: Take photos that clearly show that the generator exhaust pipe has been properly routed. Submit the photos with an authorization request for Inspected/Not Defective. See Figure 1 (Page 2) for an exemplar photo.
For Defective Units: “Before” and “after” photos will be required.
- Before beginning repairs, take several photos clearly showing the generator exhaust misrouted out the side of the motorhome. See Figure 2 (Page 2) for an exemplar photo.
- After completing repairs, take several photos that clearly display the corrected routing of the generator exhaust out the rear of the coach, under the bumper. See Figure 1 (Page 2) for an exemplar photo. Submit both sets of photos with an authorization request for Inspected/Defective/Repaired.
REPAIR PROCEDURE
NOTE: Prior to ordering parts and/or starting work, verify the size of the generator that is installed in the unit you are repairing. It will either be a 4.0 kW or 5.5 kW Onan
generator; this will affect which part is needed for the repair.
- Referencing Figure 3:
a) Remove the hardware clamping the generator exhaust hanger to the generator exhaust pipe using a ½” open end wrench and ratchet with a ½” deep well socket.
b) Once loose from the exhaust pipe, remove the generator exhaust hanger by removing the ¼” HWH screw holding it to the sidewall with a 3/8” driver bit and drill. Set aside all of the generator exhaust hanger components and fasteners for later reinstallation.
c) Using a 3/8” driver bit and drill, remove both ¼” HWH screws holding the generator exhaust pipe guard to the sidewall. Discard the generator exhaust pipe guard and mounting screws as they will not be reinstalled.
- Referencing Figure 4, remove the generator exhaust pipe by loosening the U-bolt clamp securing the generator exhaust pipe to the generator with a ratchet and a ½” deep well socket. Set aside the U-bolt exhaust clamp for later reinstallation. Discard the generator exhaust pipe as it will not be reinstalled.
- Begin reinstallation by sliding the new generator exhaust pipe onto the generator exhaust port until it is fully seated to the bottom of the fl ared end or is tight against the bottom of the generator. Be sure it is oriented so that it exits the rear of the vehicle under the bumper; reference Figures 5 and 6. Clamp in place with the U-bolt exhaust clamp previously removed in Step 6; carefully position the U-bolt so that the nuts can be easily tightened with a ratchet and a ½” deep well socket.
- Reinstall the generator exhaust hanger onto the new generator exhaust pipe below the inner edge of the rear wall using a ½” open end wrench and a ratchet with a ½” deep well socket. Then, using a 3/8” driver bit and drill, install a ¼” HWH self-tapping screw thru the third hole (from the top) of generator exhaust pipe hanger into the inside of the rear wall, 1” up from the bottom of the wall, reference Figures 7 and 8 for clarifi cation. Install a second ¼” HWH selftapping screw into the top hole on the generator exhaust hanger, taking care to not over torque as the top screw is being secured into sheet steel only.
- Use silicone sealant to seal the screw holes in the sidewall where the defective components were removed, in order to prevent water intrusion.
PHOTO REQUIREMENT: When the repair has been completed, take photos to submit with the repair claim.
TOOLS
| Wheel Chocks | Ratchet |
| Power Drill | Tape Measure |
| 3/8” Driver Bit | Caulking Gun |
| ½” Open End Wrench | Flashlight |
| ½” Deep Well Socket |
PARTS
Order only 1 of the 2 exhaust pipe part numbers listed below, depending on the model of generator installed on the vehicle with which you are working:
| Part Number | Description |
| 10774829 (ref. B65-0131) | Exhaust Pipe for Model 4.0 kW Onan |
| 10774830 (ref. B65-0132) | Exhaust Pipe for Model 5.5 kW Onan |
OBTAIN LOCALLY
Silicone
¼” HWH Self-Tapping Screws
WARRANTY LABOR ALLOWANCE:
Recall 190412REV, Flair/Admiral Model 32 S Generator Exhaust Routing
Use flat rate codes:
| 6080-11 | Inspected/Not Defective | 0.1 hr. | Prior Authorization Required |
| 6080-12 | Inspected/Defective/Repaired | 0.3 hr. | Prior Authorization Required |
If you have any questions concerning this bulletin, contact REV Dealer Technical Support:
Fleetwood Dealer Technical Support: (800) 816-9825
Monaco/Holiday Rambler
Dealer Technical Support: (877) 332-9239
Service Literature is available at: https://www.revrvdealers.com
IMPORTANT SAFETY RECALL
THIS NOTICE APPLIES TO YOUR VEHICLE
RECALL 190412REV
NHTSA # 19V306
May 2019
Dear Valued Holiday Rambler
Customer:
This notice is sent to you in accordance with the requirements of the National Traffic and Motor Vehicle Safety Act.
REV Recreation Group Inc. has decided that a safety defect relating to motor vehicle safety exists in certain model year 2019 Holiday Rambler
Admiral Model 32 S, Class A motorhomes, manufactured June 29, 2018 through March 22, 2019.
WHAT IS THE PROBLEM?
On motorhomes affected by this recall, the generator exhaust pipe was routed to exit the motorhome within its departure angle. This could cause the exhaust pipe to become damaged or sheared off if the vehicle is driven on an incline.
If the generator exhaust pipe is damaged or sheared off, it may cause carbon monoxide to intrude inside the vehicle, which could result in illness or death.
WHAT SHOULD YOU DO?
Please make certain your motorhome is immediately inspected and repaired by contacting an authorized REV Recreation Group Inc. dealer.
For assistance locating an authorized REV Recreation Group servicing dealer, please call REV Recreation Group Owner Relations toll-free at:
(800) 509-3417
WHAT WILL REV RECREATION GROUP DO?
With your continued satisfaction in mind, it is our intention to have these repairs made at your convenience with as little disruption as possible. Effective immediately, REV RV dealers have been supplied with all of the information needed to enable them to inspect, and if necessary, replace the generator exhaust pipe and properly route it.
The repair should take less than one hour to complete; however, because of service scheduling times, your dealer may need the vehicle for a longer period of time. This service will be performed for you free of charge.
When you deliver your motorhome for repairs, your dealer will complete a Repair Order. Upon completion of the repair, please sign the Repair Order and fill out the enclosed self-addressed Vehicle/Owner Information Update Card and return it to REV Recreation Group.
If you have changed your address or sold the motorhome, please take a moment to provide the name and address of the person or dealership you sold it to on the enclosed Vehicle/Owner Information Update Card and return it to REV Recreation Group. This will allow us to update our records and if necessary, notify the new owner using the information you provide.
If you have paid to have this concern corrected previously, you may be eligible for reimbursement of your cost for that repair. For more information, please contact REV Recreation Group Owner Relations at (800) 509-3417.
For more information regarding this recall, contact:
REV RECREATION GROUP OWNER RELATIONS – RECALL #190412REV
P.O. Box 1007
Decatur, Indiana 46733
(800) 509-3417
If you are unable to obtain the specified repair promptly and without charge, please contact REV Recreation Group Owner Relations using the above information.
For leased vehicles – Any vehicle lessor receiving this recall notice must forward a copy of this notice to the lessee within ten days.
If you believe that the dealer and REV Recreation Group Inc. have failed or have been unable to remedy the defect without charge or within a reasonable period of time, you may submit a complaint to:
Administrator
National Highway Traffic Safety Administration
1200 New Jersey Avenue, S.E.
Washington, DC 20590
Or call the toll-free Vehicle Safety Hotline at 1-888-327-4236
(TTY: 1-800-424-9153)
or go to https://www.safercar.gov
REV Recreation Group Inc. is taking these steps in the interest of your safety. We regret any inconvenience this may cause you.
Sincerely,
REV RECREATION GROUP INC.
Recall 190412REV
NTHSA 19V306
IMPORTANT SAFETY RECALL
THIS NOTICE APPLIES TO YOUR VEHICLE
RECALL 190412REV
NHTSA # 19V306
May 2019
Dear Valued Fleetwood Customer:
This notice is sent to you in accordance with the requirements of the National Traffic and Motor Vehicle Safety Act.
REV Recreation Group Inc. has decided that a safety defect relating to motor vehicle safety exists in certain model year 2019 Fleetwood Flair Model 32 S, Class A motorhomes, manufactured June 20, 2018 through February 22, 2019.
WHAT IS THE PROBLEM?
On motorhomes affected by this recall, the generator exhaust pipe was routed to exit the motorhome within its departure angle. This could cause the exhaust pipe to become damaged or sheared off if the vehicle is driven on an incline.
If the generator exhaust pipe is damaged or sheared off, it may cause carbon monoxide to intrude inside the vehicle, which could result in illness or death.
WHAT SHOULD YOU DO?
Please make certain your motorhome is immediately inspected and repaired by contacting an authorized REV Recreation Group Inc. dealer.
For assistance locating an authorized REV Recreation Group servicing dealer, please call REV Recreation Group Owner Relations toll-free at:
(800) 509-3417
WHAT WILL REV RECREATION GROUP DO?
With your continued satisfaction in mind, it is our intention to have these repairs made at your convenience with as little disruption as possible. Effective immediately, REV RV dealers have been supplied with all of the information needed to enable them to inspect, and if necessary, replace the generator exhaust pipe and properly route it.
The repair should take less than one hour to complete; however, because of service scheduling times, your dealer may need the vehicle for a longer period of time. This service will be performed for you free of charge.
When you deliver your motorhome for repairs, your dealer will complete a Repair Order. Upon completion of the repair, please sign the Repair Order and fill out the enclosed self-addressed Vehicle/Owner Information Update Card and return it to REV Recreation Group.
If you have changed your address or sold the motorhome, please take a moment to provide the name and address of the person or dealership you sold it to on the enclosed Vehicle/Owner Information Update Card and return it to REV Recreation Group. This will allow us to update our records and if necessary, notify the new owner using the information you provide.
If you have paid to have this concern corrected previously, you may be eligible for reimbursement of your cost for that repair. For more information, please contact REV Recreation Group Owner Relations at (800) 509-3417.
For more information regarding this recall, contact:
REV RECREATION GROUP OWNER RELATIONS – RECALL #190412REV
P.O. Box 1007
Decatur, Indiana 46733
(800) 509-3417
If you are unable to obtain the specified repair promptly and without charge, please contact REV Recreation Group Owner Relations using the above information.
For leased vehicles – Any vehicle lessor receiving this recall notice must forward a copy of this notice to the lessee within ten days.
If you believe that the dealer and REV Recreation Group Inc. have failed or have been unable to remedy the defect without charge or within a reasonable period of time, you may submit a complaint to:
Administrator
National Highway Traffic Safety Administration
1200 New Jersey Avenue, S.E.
Washington, DC 20590
Or call the toll-free Vehicle Safety Hotline at 1-888-327-4236
(TTY: 1-800-424-9153)
or go to https://www.safercar.gov
REV Recreation Group Inc. is taking these steps in the interest of your safety. We regret any inconvenience this may cause you.
Sincerely,
REV RECREATION GROUP INC.
Recall 190412REV
NTHSA 19V306
2 Affected Products
Vehicles
| FLEETWOOD | FLAIR | 2019 |
| HOLIDAY RAMBLER | ADMIRAL | 2019 |
11 Associated Documents
Recall 573 Report- Amendment 1
RCLRPT-19V306-4745.PDF 214.283KB
Remedy Instructions and TSB
RCRIT-19V306-8097.pdf 682.782KB
Defect Notice 573 Report
RCLRPT-19V306-8608.PDF 214.28KB
ISSUED Owner Notification Letter(Part 577)
RCONL-19V306-1279.pdf 111.987KB
Manufacturer Notices(to Dealers,etc)
RCMN-19V306-1083.pdf 100.917KB
Recall Acknowledgement
RCAK-19V306-4925.pdf 245.689KB
ISSUED Owner Notification Letter(Part 577)
RCONL-19V306-9375.pdf 120.423KB
Recall Quarterly Report #3, 2019-4
RCLQRT-19V306-9262.PDF 211.321KB
Recall Quarterly Report #1, 2019-2
RCLQRT-19V306-9400.PDF 211.137KB
ISSUED Renotification Notice
RCRN-19V306-0005.pdf 206.934KB
ISSUED Renotification Notice
RCRN-19V306-8178.pdf 218.163KB
Latest Recalls Documents
- 9500 Running Watts and 12500 Peak Watts (Gasoline); 8500 Running Watts, 11200 Peak Watts (Propane); Remote Start with Included Key Fob, Electric and Recoil Start; Up to 12 Hours of Run Time on a 6. 6 Gallon Fuel Tank with Fuel Gauge
- Features Two GFCI 120V 5–20R 20A Standard Household Receptacle, One Transfer Switch Ready 120V L14-30R 30A, and One RV Ready 120/240V 14–50R 50A; All Outlets Have Rubber Covers for Added Safety
- Powered by a Heavy Duty 457cc Westinghouse 4-Stroke OHV Engine Featuring a Long-Lasting Cast Iron Sleeve with Automatic Low Oil Shutdown and Digital Hour Meter. VFT display gives you real time updates with the voltage output, frequency, and lifetime hours
- Plug-and-Play: Comes with a Remote Start Key Fob, 12V Battery Charger, Oil, an Oil Funnel, a Tool Kit, and a User’s Manual to Get You Started Right Out of the Box (Minimal Assembly Required)
- All Westinghouse Portable Generators are Functionally Tested in the Factory and May Contain Minimum Residual Oil and/or Fuel Odor; EPA Compliant; Backed By 3-Year Limited Service, Labor, and Parts Coverage and Nationwide Customer Service Network
- With 13,000 watts of power, the XP13000EH Dual Fuel generator will keep your whole home running during a storm or power outage
- DuroMax is the industry leader in Dual Fuel portable generator technology, with a full assortment ranging from digital inverters to generators that can power your entire home
- At the core of all our products resides a robust DuroMax engine. Designed for Power. Designed to Last
- The XP13000EH comes with a push button start, a front facing interface that allows you to change your fuel type in seconds, and a wide variety of outlets (including a transfer switch-ready 50 amp outlet)
- Constructed with a heavy-duty all metal frame and power panel - No plastic parts
- Ultralight body weighs in at a mere 39 pounds for easy transport and storage
- Extremely quiet operation comparable to the sound of a normal conversation according to the US Department of Health and Human Services
- Produces 2350 surge watts and 1900 rated watts of clean power for safe charging of sensitive electronics (phones, tablets, televisions, computers, etc.)
- Fuel shutoff maximizes the generator’s lifespan by using up the remaining fuel in the carburetor before shutting down
- Includes two three-prong 120V receptacles, one 12V DC receptacle, two 5V USB ports, and a two-year warranty
- Powerful Output: 4400 peak watts and 3400 running watts, 2*120V AC ports, 1* 30A RV port, 1*12V DC port, 14 hours runtime at 25% load
- Gas Powered: 2 gallon fuel tank capital
- Features: Inverter technolog, ECO mode, EPA compliment, RV ready, overload protection, low oil shutdown, cold start technology
- Portable Generator: Weight 56lbs, lightweight and easy to move
- Note: All Oxseryn generators are functionally tested in the factory, so there may be a slight smell of gas when you receive it
- 224cc dual-fuel engine runs on both gasoline (6800 surge watts, 5100 rated watts) and propane (6000 surge watts, 4500 rated watts)
- Bonded-neutral 240V configuration provides low-power Level 2 charging for battery and hybrid
electric vehicles - The WEN Watchdog CO Shutdown Sensor helps protect both you and your family by automatically turning off the generator if dangerous levels of carbon monoxide are detected
- Fuel shutoff maximizes the generator’s lifespan by using up the remaining fuel in the carburetor before shutting down
- Includes fuel shut-off to help limit maintenance, onboard wheels, a telescoping pull handle, one L14-30R 120V/240V receptacle, two three-prong 120V receptacles, one TT-30R RV receptacle, one 12V DC receptacle, two 5V USB ports, a voltage selector switch, a tool-free LPG quick-connector, a six-foot-long LPG regulator hose, and a three-year warranty
This product presentation was made with AAWP plugin.