June 17, 2021 NHTSA CAMPAIGN NUMBER: 21V459000
Incorrect Electrical Connection on Pump Harness
A poor connection at the terminals may cause the vehicle to not shift into pump mode, hindering fire fighting efforts and increasing the risk of injury.
NHTSA Campaign Number: 21V459
Manufacturer Spartan Fire
, LLC
Components EQUIPMENT
Potential Number of Units Affected 62
Summary
Spartan Fire
, LLC is recalling certain 2019-2021 S180 Pumper emergency vehicles. The pump shift harness may have incorrect terminals, which could result in a poor electrical connection.
Remedy
Dealers will replace the terminals on the harness, free of charge. Owner notification letters were mailed on July 9, 2021. Owners may contact Spartan Fire
customer service at 1-517-543-6400. Spartan Fire
’s number for this recall is 21012.
Notes
Owners may also contact the National Highway Traffic Safety Administration Vehicle Safety Hotline at 1-888-327-4236 (TTY 1-800-424-9153), or go to www.nhtsa.gov.
APPLIES TO:
This Recall service bulletin applies to 2019 through 2021 model year, S-180 model emergency response pumpers built between April 2019 and November 2020.
CONDITION:
Incorrect terminal installed on harness connected to pump control solenoid.
CORRECTION:
Replace with correct terminals.
GENERAL INSTRUCTIONS:
Thoroughly review entire service bulletin before starting work. If there are questions or concerns with steps defined in this service bulletin, contact Spartan Fire
, LCC. Customer & Product Support Group.
All applicable industry safety standards must be followed when performing work identified in this procedure.
SEOCONTENT-START
Recall Service Bulletin
Recall Service Bulletin
RSB21-500-001
Page 1 of 5 CPS-FR-0008
Rev: 1.0
21012
Service Bulletins are intended for use by Professional Technicians only. They are written to guide Professional Technicians in performing service to
vehicles of specific nature in conjunction with industry standards. Professional Technicians are appropriately trained on industry standards and have
the tools and equipment to perform procedures safely and properly.
DATE: 7/8/2021
APPLIES TO: This Recall service bulletin applies to 2019 through 2021 model year, S-
180 model emergency response pumpers built between April 2019 and
November 2020.
NHTSA/TC Id: 21V-459
CONDITION: Incorrect terminal installed on harness connected to pump control
solenoid.
CORRECTION: Replace with correct terminals.
LABOR ALLOCATION: 1 Hour
CLASSIFICATION: V3
PARTS NEEDED:
QTY Part Number Description
4 12124580 Weather-Pack female terminal
4 12010293 Weather-Pack cable seal
GENERAL INSTRUCTIONS:
Thoroughly review entire service bulletin before starting work. If there are questions or concerns
with steps defined in this service bulletin, contact Spartan Fire
, LCC. Customer & Product Support
Group.
All applicable industry safety standards must be followed when performing work identified in this
procedure.
Recall Service Bulletin
Recall Service Bulletin
RSB21-500-001
Page 2 of 5 CPS-FR-0008
Rev: 1.0
21012
Service Bulletins are intended for use by Professional Technicians only. They are written to guide Professional Technicians in performing service to
vehicles of specific nature in conjunction with industry standards. Professional Technicians are appropriately trained on industry standards and have
the tools and equipment to perform procedures safely and properly.
STEP-BY-STEP INSTRUCTIONS:
1. Locate 2 connectors that connect the harness to the pump shift control solenoid. These are
typically located towards the middle of the truck on the drivers side frame rail. Road Solenoid
connector will have orange wire labeled ERV738 & black wire labeled ERV510D. Pump solenoid
connector will have blue wire labeled ERV739 & black wire labeled ERV510E.
2. Identify type of connector. Deutsch or Weather-Pack. See Figure 2.1
Figure 2.1
3. If connection is made with Deutsch connector no further action is needed. If connection is
made with Weather-Pack connector move on to step 4.
4. Disconnect both Weather-Pack connectors that connect the harness to the pump shift control
solenoid.
5. Inspect the harness side connector (Female connector assembly) terminals to verify they are
a female (sleeve) terminal, not a male (pin) terminal. See figure 3.1
Recall Service Bulletin
Recall Service Bulletin
RSB21-500-001
Page 3 of 5 CPS-FR-0008
Rev: 1.0
21012
Service Bulletins are intended for use by Professional Technicians only. They are written to guide Professional Technicians in performing service to
vehicles of specific nature in conjunction with industry standards. Professional Technicians are appropriately trained on industry standards and have
the tools and equipment to perform procedures safely and properly.
Figure 3.1
6. If female (sleeve) terminals are installed the connection is correct & the connectors can be
reconnected as they were.
7. If male (pin) terminals were installed in the female connector assembly they will need to be
replaced with the correct female (sleeve) terminals.
8. Open hinged TPA on female connector assembly. (See cross sectional view in figure 3.1 above
for hinged TPA location)
9. Insert terminal removal tool into front of female connector assembly & remove incorrect
male (pin) terminal. See Figure 4.1
Recall Service Bulletin
Recall Service Bulletin
RSB21-500-001
Page 4 of 5 CPS-FR-0008
Rev: 1.0
21012
Service Bulletins are intended for use by Professional Technicians only. They are written to guide Professional Technicians in performing service to
vehicles of specific nature in conjunction with industry standards. Professional Technicians are appropriately trained on industry standards and have
the tools and equipment to perform procedures safely and properly.
Figure 4.1
10. Cut wire just below removed terminal & discard male terminal.
11. Strip wire insulation leaving approx. ¼” of exposed wire.
12. Insert 12010293 cable seal on to wire before the crimping of 12124580 female terminal
sleeve onto wire. Inspect to make sure terminal is straight and not bent. Ensure the conductors
are crimped to the conductor grip of the terminal and the cable seal is crimped along with the
wire insulation grip. (See figure 4.2 showing proper crimp around seal & insulation)
Figure 4.2
Recall Service Bulletin
Recall Service Bulletin
RSB21-500-001
Page 5 of 5 CPS-FR-0008
Rev: 1.0
21012
Service Bulletins are intended for use by Professional Technicians only. They are written to guide Professional Technicians in performing service to
vehicles of specific nature in conjunction with industry standards. Professional Technicians are appropriately trained on industry standards and have
the tools and equipment to perform procedures safely and properly.
13. Insert female terminal into connector location where male terminal was previously removed.
(See figure 5.1 showing proper wire locations)
Figure 5.1
14. Continue steps 8 thru 12 until all incorrect terminals have been replaced. (4 terminals on 2
connectors)
15. Check pump operation to ensure Road and Pump Modes work properly.
a. Turn on the master battery and ignition switches.
b. Ensure the park brake is set.
c. Start the truck.
d. Engage the water pump using the switch in the cab. Make sure to follow all
operational and safety placards in the cab relating to engaging the pump.
i. Do not run the water pump for more than 30 seconds without opening
the tank to pump valve to recirculate tank water through the pump.
e. Verify the “Pump Engaged” indicator light in the cab is illuminated.
f. Disengage the water pump using the switch in the cab.
g. Verify the “Pump Engaged” indicator light in the cab is no longer illuminated.
h. Turn off the ignition and master battery switch.
*************************************************************************************************************
July 9, 2021
This notice applies to
Dear Valued Customer,
EMERGENCY RESPONSE
Srandon, SD I Charlotte, Mt I Ephrata, PA Snyder, NE
SPARTANER.COM
This notice is sent to you in accordance with the National Traffic and Motor Vehicle Safety Act.
Spartan Fire
, LLC has decided t hat a defect which relates to motor vehicle safety exists in certain model
year 2019-2021, S-180 model emergency response pumpers.
Please note: The Vehicle Identification Number that may be affected by this recall is located at the top
of this letter.
What is the defect?
On the affected vehicles, the harness manufacturer installed the incorrect terminals within one side of
the connectors, resulting in a male to male terminal connection where it should have been a male to
female terminal connection. When the incorrect terminals are installed, this may cause a poor
connection and the vehicle to not shift into pump mode when requested.
A poor connection at the terminals may cause the vehicle to not shift into pump mode when
requested. This increases the risk of personal injury and equipment damage. The issue could occur
without warning.
Corrective Action:
Spartan dealers will remove and replace the terminals at no charge.
Labor Time:
Removal of the affected pump shift harness terminals and installation of the new terminals may take up
to 1 hour.
Spartan Fire
, LLC
Spartan Fire
, LLC
What You Should Do:
Contact your local dealer to have the work performed. If you cannot locate a dealer, call Spartan at 1-
800-867-6478 to locate your nearest dealer. Steps will be taken to ensure the recall is performed at
the nearest dealer.
Leased Vehicles:
The lessor must notify the lessee by first class mail within ten (10) days from receipt of their owner
notification letter from the manufacturer; both for the initial notification and all subsequent
notifications.
Reimbursement:
If you had this repair performed before you received this letter, you may be eligible to receive
reimbursement for the cost of obtaining a pre-notification remedy of the problem associated with this
recall. For more information contact Spartan at 1-800-867-6478.
Information Change:
If you have changed your address, sold or traded your vehicle, please email us at
[email protected] to provide updated information.
If the authorized service center has failed or is unable to remedy the defect without charge and within a
reasonable time, contact Spartan at 1-800-867-6478. You may also submit a complaint to the
Administrator, National Highway Traffic Safety Administration, 1200 New Jersey Avenue SE, Washington,
D.C. 20590 or call the Auto Safety Hotline at 1-888-327-4236 (TTY: 1-800-424-9153); or go to
https://www.safercar.gov if you feel the manufacturer has failed or is unable to remedy the defect
without charge.
We regret any inconvenience this service may cause you. Your safety and continued satisfaction with the
quality and performance of your chassis is of the utmost concern to us.
Sincerely,
Spartan Fire
, LLC
SEOCONTENT-END
3 Affected Products
Vehicle
| MAKE | MODEL | YEAR |
| SPARTAN FIRE | S180 PUMPER | 2019-2021 |
7 Associated Documents
Owner Notification Letter(Part 577)
RCONL-21V459-8735.pdf 192.061KB
Recall Acknowledgement
Defect Notice 573 Report
RCLRPT-21V459-1247.PDF 213.531KB
Remedy Instructions and TSB
RCRIT-21V459-2886.pdf 421.591KB
Recall Quarterly Report #1, 2021-3
RCLQRT-21V459-0605.PDF 211.135KB
Recall 573 Report- Amendment 1
RCLRPT-21V459-4918.PDF 213.658KB
Recall Quarterly Report #2, 2021-4
RCLQRT-21V459-7571.PDF 211.236KB
Latest Recalls Documents
- 3:1 Heatshrink Ratio: The heat shrink butt connector has dual-wall shrinking tube and inside hot melt glue, providing a fully safe seal and wire corrosion. Its dual wall insulation seals against moisture corrosion, air leakage, and can be used underground
- Premium Copper Core: The butt splice terminals use seamless and high-quality thick copper tubular, which makes the connection project safer! Fix the wire firmly, increase current flow, and decrease voltage drop
- Wide Usage: Our heat shrink wire connector is ideal for marine, automobile, industry, electrical and electronics. Whether working on boat, vehicle, RC car, home, scientific project, car stereo, or electrical DIY, the crimp connectors will work well
- Package Included: 50 pcs red waterproof wiring connectors for 22, 20, 18, 16 gauge wires, 40 pcs blue waterproof wiring connectors for 16, 14 gauge wires, 10 pcs yellow waterproof wiring connectors for 12, 10 gauge wires—total 100 pcs
- AIRIC Brand Advantages: As a professional manufacturer of electrical accessories, we own a large leading wire connectors factory and get UL, CE, ROHS, SGS, and ISO9001-2005 international
quality system certification
- COMPLIANT WITH ALL RELEVANT STANDARDS:With Haisstronica 330PCS( A.W.G.:22-16 150 PCS,16-14 100 PCS,12-10 32 PCS,26-24 48 PCS) heat shrink waterproof wire connectors are compliant with ROHS, ISO 9001:2008, SGS, and CE standards
- HIGH-QUALITY COPPER CORE:Heat shrink butt connectors use a copper core with a higher thickness rating.This makes your connection project safer and better meets our customers’ quality needs
- HIGH-QUALITY HEAT SHRINK:Translucent heat shrink tubing provides high tensile strength and resistance to stretch and minimize mechanical damage.The thick barrel ensures a strong crimp every time.The inner wall of the heat-shrinkable tube has enough hot melt adhesive to ensure waterproof performance reliability.Your wire will never slip out of these heat shrink wire connectors
- RECOGNIZABLE:Tubings of varying colors with easily recognizable wire gauge markings. Simply measure the wiring, and by checking the mark of wire gauge of the polyolefin tubing, then you can quickly choose the right connector
- WIDE APPLICATIONS: High quality 3:1 shrinkage tubing has a heat-activated sealant lining to provide complete secure seal. It's flame-retardant, waterproof, and can be used underground. Compliant with all electrical standards, Perfect for marine and automobile applications, whether you are working on your boat, Vehicle, Home or scientific project
- Time Saver: Solderless,crimpless, all you need is just a heat gun to finish the joint, much faster and easier than the old way
- Fit for Confined and Narrow Spaces: Can be bent after connection and no need to crimp or solder in the confined area, just control the temperature via a heat gun
- Waterproof and Seal Performance: There is two hot melt waterproof adhesive rings in each butt connector, which help it hold up better to moisture
- High Temperature Proof in A Short Time: Use exclusive material in the butt connectors to avoid shrink tubing melting before solder ring
- IATF16949:2016 Listed: The Kuject solder seal connectors meet the newest standard of International
Automotive Task Force, which is the most standardized way for you to repair or modify your car
- ✔️【PREMIUM QUALITY】Thick copper barrel ensures strong secure crimping every time, providing minimal voltage drop, high current flow, and less heat. These will prevent short circuits and problematic wiring that inferior connectors are known for
- ✔️【DURABILITY】Each terminal features a thick tinned copper barrel that resists corrosion to hold the wire tight when crimped. The barrel is created from one seamless piece of copper that eliminates the problem of the barrel opening. Your wire will never slip out of the connector
- ✔️【WATERPROOF】Insulation tubing has unique dual-walled design. High quality 3:1 shrinkage tubing has a heat-activated sealant lining to provide a 360 degree secure seal. It's flame-retardant, waterproof, and can be used underground
- ✔️【WIDE APPLICATIONS】Compliant with all electrical standards, Perfect for marine and automobile applications, whether you are working on your boat, Vehicle, Home or scientific project, our electrical crimp connector will ensure strong watertight seal to make sure everything bond correctly. The connector assortment includes red (AWG 22 – 16), blue (AWG 16 – 14) and yellow (AWG 12 – 10) butt connectors that can be used on wire AWG from 22 to 10
- ✔️【TICONN BRAND QUALITY COMMITMENT】We stand behind the quality of our products. If for any reason you are not satisfied with your purchase, please contact us.
- [EXECELLENT QUALITY] : Direct factory with excellent quality control, STRONG & DURABLE. The copper core of our heat shrinkable joints is made of high quality tinned copper, in addition to being extremely conductive, it is easier to flatten and grip the wire
- [EASY USE] : Take two wires you wish to join. Remove the wire insulator, pick the terminal color you want. Insert the wire into the terminal one at the time and crimp by crimping tool, insert another terminal and crimp. Use air gun to apply heat on the heat shrink connectors.
- [PRACTICAL DESIGN] : Double-wall design, outer layer of polyolefin tube, inner layer of hot melt adhesive, precise crimping and good contact. Electrical butt connectors provide high tensile strength and adequate hot melt adhesive inside the tube. After shrinking, the wiring is firm and not loose, and it can ensure that the current continues to flow smoothly.
- [WIDE APPLICATIONS] : Our waterproof terminals are perfect for marine, automobile applications, electrical and electronics industries. Whether working on your Boat, Vehicle, Home, or Scientific project, the electrical crimp connector will ensure a strong waterproof seal to make sure everything bonds correctly.
- [PACKAGE INCLUDED] : 25 pcs red connector ( 22-16 AWG ), 15 pcs blue connector ( 16-14 AWG ), 10 pcs yellow connector ( 12-10 AWG ).
Last update on 2026-05-25 / Affiliate links / Images from Amazon Product Advertising API
This product presentation was made with AAWP plugin.