November 1, 2021 NHTSA CAMPAIGN NUMBER: 21V849000
Transfer Switch Wires May Come Loose
Loose wires can cause electrical arcing, increasing the risk of a fire.
NHTSA Campaign Number: 21V849
Manufacturer Heartland
Recreational Vehicles, LLC
Components ELECTRICAL SYSTEM
Potential Number of Units Affected 1,783
Summary
Heartland
Recreational Vehicles, LLC (Heartland
) is recalling certain 2020-2021 Heartland
Cyclone and 2019-2021 Road Warrior Toy Hauler recreational trailers. The transfer switch wire securement lugs may have been improperly tightened during production, causing the wires to come loose.
Remedy
Dealers will inspect and tighten the securement lugs, free of charge. Owner notification letters were mailed December 16, 2021. Owners may contact Heartland
customer service at 1-877-262-8032.
Notes
Owners may also contact the National Highway Traffic Safety Administration Vehicle Safety Hotline at 1-888-327-4236 (TTY 1-800-424-9153), or go to www.nhtsa.gov.
21v849 & 2021-668
WC : 99.01.62
Transfer switch Torque Verification
1. Disconnect shore power. Turn battery disconnects to the off position.
3. Once access has been gained to transfer switch, remove cover using a 1/4โ socket to loosen set screw.
4. Once cover has been removed from the transfer switch using an in.lbs torque screwdriver /wrench tighten each conductor lug to the specified torque indicated on the inside of the transfer switch cover or in the installation instructions.
5. Torque specs listed on the inside of the transfer switch cover.
Tools Needed
1. Screw gun with number two square bit.
2. 1/4โ socket or wrench.
3. IN.LBS torque screwdriver or wrench.
4. 5/32โ hex bit.
5 Affected Products
Vehicles
8 Associated Documents
Defect Notice 573 Report
RCLRPT-21V849-9369.PDF 215.592KB
Recall Acknowledgement
RCAK-21V849-4890.pdf 646.013KB
Recall 573 Report – Amendment 1
RCLRPT-21V849-7553.PDF 215.634KB
Recall Quarterly Report #1, 2021-4
RCLQRT-21V849-0187.PDF 211.139KB
Remedy Instructions and TSB
RCRIT-21V849-9011.pdf 590.817KB
Recall Quarterly Report #2, 2022-1
RCLQRT-21V849-1193.PDF 211.245KB
Recall Quarterly Report #3, 2022-2
RCLQRT-21V849-7851.PDF 211.325KB
Recall Quarterly Report #4, 2022-3
RCLQRT-21V849-6300.PDF 211.433KB
Latest Recalls Documents
- Seamlessly integrates with inverters, shore power, and generators for reliable electricity management.
- Provides automatic power switching between two separate 30 amps AC input sources.
- Features a time delay of 20-30 seconds to allows the generator voltage to stabilize.
- Designed for 120V systems, it accommodates standard residential and RV electrical requirements.
- Combining mechanical and electrical capabilities, it ensures efficient power distribution and control.
- ใSeamless Power Switching for Uninterrupted SupplyใAutomatically switches to backup power when the main source fails, and back again once it's restoredโno manual action needed, ensuring continuous power flow. Widely used in shore power, solar inverters, and generators.
- ใVersatile Compatibility Across ApplicationsใFully compatible with Renogy
1000W, 2000W, 3000W pure sine wave inverters and other brands' battery inverters. Ideal for RVs, camping vans, off-grid systems, and backup home power setups. - ใBuilt Tough for Harsh EnvironmentsใConstructed with high-quality, heat-resistant, and corrosion-proof ABS materials, built to withstand challenging conditions and deliver long-lasting performance.
- ใEasy Installationใ Mounts securely to walls or floors using built-in screw holes. Designed for dry, well-ventilated locations. For outdoor use, installation in a waterproof enclosure is required to protect against moisture.
- ใBuilt-In Time Delayใ Features a 20โ30 second delay when switching to generator power, helping to stabilize voltage during startup and protect connected equipment from power surges or frequent switching.
- Nirakoka RV Automatic Transfer Switch has been pre-wired to automatically change the primary source of AC current from shore power to generator or inverter power when activated.
- WIDE APPLICATION โ Applied to RVs, speedboats, and various high-power equipment that requires emergency power supply.
- AUTOMATICALLY SWITCH โ This Automatic Transfer Switch 50 AMP can be used to automatically switch between inverter power and a generator. It switches to inverter power when the generator stops running. In the event of a inverter power outage, the generator will start automatically. The green L.E.D is lit when generator power is present.
- DOUBLE PROTECTION โ Double protection of built-in mechanical interlocks and control circuits prevents two separate 120/240 volt AC power sources from entering the AC distribution board at the same time and causing a short circuit.
- TIME DELAY CIRCUIT โ Once AC power from the Generator is sensed by this RV Automatic Transfer Switch, it will start a timer and automatically switch over to generator power supply after a 20-45 sec delay which ensures the generator has sufficient time to run up to speed before electrical load is applied.
- [UNIVERSAL FIT] Fit type: universal fit. If you are using public power and it goes out, when the generator is turned on it will automatically switch the power to it. The green light is in an active state.
- [FUNCTION] Time delay circuit board ensures generator voltage is at a stable level before transfer occurs. Automatically senses generator power and prevents two power sources from entering the AC distribution panel at the same time.
- [SPECIFICATION] 120/240 VAC, 50 Amp.
- [EASY TO USE] Easy-to-remove protective cover with wiring schematic inside. This automatic transfer switch has a 30 second selectable delay with quick-connect terminals for easy installation.
- [NOTICE] For any reason, if you are not satisfied with your purchase, contact us directly.
- Automatic Transfer Switch: The automatic transfer switch on our generators is configured to prioritize generator power. When the generator stops running, it automatically switches to utility power with a green light indicating that generator power is active. In addition, the transfer switch continuously monitors the status of the utility power, so that if the utility power goes out, the generator will automatically start without the need for additional wiring, providing you with great convenience.
- Dual Protection: The 50 AMP Automatic Transfer Switch is pre-wired to automatically convert the primary source of AC power from shore power to generator or inverter power upon startup. Mechanical interlocks and control circuits are protected against short circuits caused by two separate 120/240 volt AC power sources entering the AC switchboard at the same time.
- RV Transfer Switch: This automatic transfer switch is perfect for anyone who needs seamless power management for their RV or speedboat. With an operating voltage of 240VAC, a current rating of 50A and a neutral current of 70A, this switch can efficiently switch between different power sources, ensuring that you won't run out of power while you're traveling.
- Easy Installation: Our 50 Amp Transfer Switch has an easy to remove protective cover with wiring diagram. When installing, note that there are different locations for light and heavy duty wires. Before proceeding, please note where they are connected and after plugging in the power cord, reinsert the light duty cord into its original position. You can also find installation videos on youtube.
- Strong Construction: Made of sturdy and durable metal casing, the product surface is coated with a coating process that is waterproof, rust-proof and corrosion-resistant, which is ideal for outdoor RV or home emergency back-up use and ensures long-lasting performance under all conditions. If you have any question about this generator transfer switches, please contact us.
Last update on 2026-05-27 / Affiliate links / Images from Amazon Product Advertising API
This product presentation was made with AAWP plugin.
SEOCONTENT-START
OMB Control No.: 2127-0004 Part 573 Safety Recall Report 21V-849 The information contained in this report was submitted pursuant to 49 CFR ยง573 Manufacturer Name : Heartland
Recreational Vehicles, LLC Submission Date : NOV 01, 2021 NHTSA Recall No. : 21V-849 Manufacturer Recall No. : NR Manufacturer Information : Manufacturer Name : Heartland
Recreational Vehicles, LLC Address : 1001 All Pro Drive Elkhart IN 46514 Company phone : 8772628032 Population : Number of potentially involved : 1,783 Estimated percentage with defect : 10 % Vehicle Information : Vehicle 1 : 2020-2021 Heartland
Cyclone Vehicle Type : TRAILERS Body Style : OTHER Power Train : NR Descriptive Information : The population was determined by 4 weeks of production prior to the first known incident. The end date is 4 weeks of production after last known incident. Production Dates : JUL 08, 2019 – APR 27, 2021 VIN Range 1 : Begin : 5SFCG4633LE424486 End : 5SFCG4021ME471937 โ Not sequential Vehicle 2 : 2019-2021 Heartland
Road Warrior Vehicle Type : TRAILERS Body Style : OTHER Power Train : NR Descriptive Information : Population was determined by 4 weeks production prior to first known incident. End date is 4 weeks of production after last known incident. Production Dates : FEB 20, 2018 – NOV 11, 2020 VIN Range 1 : Begin : 5SFCG4434KE385781 End : 5SFCG463XME455851 โ Not sequential Description of Defect : Description of the Defect : Transfer switch wire securement lugs may not have been properly torqued to the manufacture’s installation instructions during production. FMVSS 1 : NR FMVSS 2 : NR Description of the Safety Risk : Improper torque on the lugs could cause the wires to become loose in the Part 573 Safety Recall Report 21V-849 Page 2 The information contained in this report was submitted pursuant to 49 CFR ยง573 Description of the Safety Risk : transfer switch. If the wires become loose it could cause the wires to arch and possibly start a thermal event. This could lead to and increased risk of fire and injury. Description of the Cause : Production may not have verified proper torque of the lugs in the transfer switch box during the manufacturing process. Identification of Any Warning that can Occur : Loose wires could cause intermittent or loss of power in the unit. You may also smell hot or melting wires coming from the pass through storage area. Involved Components : Component Name 1 : NR Component Description : NR Component Part Number : NR Supplier Identification : Component Manufacturer Name : NR Address : NR NR Country : NR Chronology : See Attached document Description of Remedy : Description of Remedy Program : The remedy will be to have your local dealer or service center inspect and verify proper torque on the lugs within the Transfer switch box. This inspection will be done at no cost to the owner. All Reimbursements will be covered by Heartland
’s general reimbursement plan. How Remedy Component Differs The remedy component would have the wire securement lugs torqued to Part 573 Safety Recall Report 21V-849 Page 3 The information contained in this report was submitted pursuant to 49 CFR ยง573 from Recalled Component : the proper values as stated on the Transfer switch box. Values vary by manufacture. Identify How/When Recall Condition was Corrected in Production : We have provided proper training and tools to the individuals installing the transfer switch boxes. We have installed a group lead verification signoff of proper torque specs being met on the production line. Recall Schedule : Description of Recall Schedule : Heartland
will begin notifying owners/dealers once letters are approved Planned Dealer Notification Date : DEC 29, 2021 – DEC 29, 2021 Planned Owner Notification Date : DEC 29, 2021 – DEC 29, 2021 * NR – Not Reported
**************************************************************************************************************
OMB Control No.: 2127-0004 Part 573 Safety Recall Report 21V-849 The information contained in this report was submitted pursuant to 49 CFR ยง573 Manufacturer Name : Heartland
Recreational Vehicles, LLC Submission Date : NOV 04, 2021 NHTSA Recall No. : 21V-849 Manufacturer Recall No. : NR Manufacturer Information : Manufacturer Name : Heartland
Recreational Vehicles, LLC Address : 1001 All Pro Drive Elkhart IN 46514 Company phone : 8772628032 Population : Number of potentially involved : 1,783 Estimated percentage with defect : 10 % Vehicle Information : Vehicle 1 : 2020-2021 Heartland
Cyclone Vehicle Type : TRAILERS Body Style : OTHER Power Train : NR Descriptive Information : The population was determined by 4 weeks of production prior to the first known incident. The end date is 4 weeks of production after last known incident. Production Dates : JUL 08, 2019 – APR 27, 2021 VIN Range 1 : Begin : 5SFCG4633LE424486 End : 5SFCG4021ME471937 โ Not sequential Vehicle 2 : 2019-2021 Heartland
Road Warrior Vehicle Type : TRAILERS Body Style : OTHER Power Train : NR Descriptive Information : Population was determined by 4 weeks production prior to first known incident. End date is 4 weeks of production after last known incident. Production Dates : FEB 20, 2018 – NOV 11, 2020 VIN Range 1 : Begin : 5SFCG4434KE385781 End : 5SFCG463XME455851 โ Not sequential Description of Defect : Description of the Defect : Transfer switch wire securement lugs may not have been properly torqued to the manufacture’s installation instructions during production. FMVSS 1 : NR FMVSS 2 : NR Description of the Safety Risk : Improper torque on the lugs could cause the wires to become loose in the Part 573 Safety Recall Report 21V-849 Page 2 The information contained in this report was submitted pursuant to 49 CFR ยง573 Description of the Safety Risk : transfer switch. If the wires become loose it could cause the wires to arch and possibly start a thermal event. This could lead to and increased risk of fire and injury. Description of the Cause : Production may not have verified proper torque of the lugs in the transfer switch box during the manufacturing process. Identification of Any Warning that can Occur : Loose wires could cause intermittent or loss of power in the unit. You may also smell hot or melting wires coming from the pass through storage area. Involved Components : Component Name 1 : Transfer Switch Component Description : Automatic Transfer Relay Switch Component Part Number : Progressive Dynamics Model PD52 Supplier Identification : Component Manufacturer Name : NR Address : NR NR Country : NR Chronology : See Attached document Description of Remedy : Description of Remedy Program : The remedy will be to have your local dealer or service center inspect and verify proper torque on the lugs within the Transfer switch box. This inspection will be done at no cost to the owner. All Reimbursements will be covered by Heartland
’s general reimbursement plan. How Remedy Component Differs The remedy component would have the wire securement lugs torqued to Part 573 Safety Recall Report 21V-849 Page 3 The information contained in this report was submitted pursuant to 49 CFR ยง573 from Recalled Component : the proper values as stated on the Transfer switch box. Values vary by manufacture. Identify How/When Recall Condition was Corrected in Production : We have provided proper training and tools to the individuals installing the transfer switch boxes. We have installed a group lead verification signoff of proper torque specs being met on the production line. Recall Schedule : Description of Recall Schedule : Heartland
will begin notifying owners/dealers once letters are approved Planned Dealer Notification Date : DEC 29, 2021 – DEC 29, 2021 Planned Owner Notification Date : DEC 29, 2021 – DEC 29, 2021 * NR – Not Reported
SEOCONTENT-END