May 6, 2022 NHTSA CAMPAIGN NUMBER: 22V306000
Protective Cover Missing from 12-Volt Mini Breaker
Electrical arcing between the exposed studs and nearby aluminum ducting can increase the risk of fire and injury.
NHTSA Campaign Number: 22V306
Manufacturer Cruiser RV![]()
Components ELECTRICAL SYSTEM
Potential Number of Units Affected 29
Summary
Cruiser RV
(Cruiser) is recalling certain . The 12-volt mini
breaker cover for the slide-out was not installed during production, leading to exposed studs that could cause electrical arcing.
Remedy
Dealers will inspect the 12-volt mini
breaker for the slide-out, and install a cover if necessary, free of charge. Owner notification letters were mailed June 21, 2022. Owners may contact Cruiser customer service at 1-574-206-7920.
Notes
Owners may also contact the National Highway Traffic Safety Administration Vehicle Safety Hotline at 1-888-327-4236 (TTY 1-800-424-9153), or go to www.nhtsa.gov.
CRUISER MINI
BREAKER 22V306 & 2022-240
WCC: 99.03.22
RATE: .3
Tools needed:
1. Screw gun with proper bit (square bit for access panel)
2. Philips bit for panel box
3. 3/8” socket or wrench
Parts List
1. 11131: Boot – (VTE-464NOV02) – Rubber
How to.
1. Locate Panel Box (See Picicture 1)
a. Some floor plans may have an access panel that you can reach the mini
breaker through
b. If there is an access panel remove panel with square bit to access mini
breaker otherwise,
2. Remove Panel box with Philips screw driver or bit (Picture 2)
3. Once removed, locate 12 volt mini
breaker secured on the floor behind panel box (Picture 3 & 4)
4. Add rubber boot to top of mini
breaker (part 11131: Boot – VTE-464NOV02 – Rubber)
a. Remove the two wire retaining nuts with a 3/8” socket or wrench
b. Lift up wires
c. Add the red rubber boot
d. Replace the wires and secure with nuts.
e. Cap posts with boot cover (as seen in picture 4)
5. Replace panel box
Chronology :
4/26/22 received an email from Cruiser Production about missing covers on mini
breakers. 4/27/22 –
4/29/22 Ran warranty claims and determined scope and range. 4/29/22 – called safety committee meeting.
4/30/22 voted to recall. We have had zero warranty claims and zero personal injuries or property damage.
1 Affected Product
Vehicle
| MAKE | MODEL | YEAR |
| CRUISER | SHADOW CRUISER | 2022 |
7 Associated Documents
Recall Acknowledgement
RCAK-22V306-6121.pdf 645.781KB
Defect Notice 573 Report
RCLRPT-22V306-2565.PDF 215.27KB
Owner Notification Letter(Part 577)
RCONL-22V306-7672.pdf 201.147KB
Remedy Instructions and TSB
RCRIT-22V306-1802.pdf 363.193KB
Recall Quarterly Report #1, 2022-2
RCLQRT-22V306-1513.PDF 211.122KB
Recall Quarterly Report #2, 2022-3
RCLQRT-22V306-5282.PDF 211.225KB
Recall Quarterly Report #3, 2022-4
RCLQRT-22V306-5473.PDF 211.31KB
Latest Recalls Documents
- FUNCTIONS: Used to protect 12V 24V 36V 48V 60V 100V DC circuit from overload and short circuit damage, and can also be used for control and isolation.
- ARC EXTINGUISHING: This DC mini
circuit breaker has a magnetic system to assist arc extinguishing. - CURVE B: Magnetic trip range 4-7 times rated current.
- APPLICATION: Used in battery power systems, solar photovoltaic systems, RV, electric moped, or other DC systems.
- INSTALLATION: Screw clamps wire or M5 wire lug (size fits), 35 mm DIN rail mount or surface mount.
- ATM Automatic Reset Fuses Circuit Breakers: Type 1 mini
fuses circuit breakers with 0.32 inch (8.1mm) centerline spacing termination for ATM fuse block/ fuse panel/ fuse box/ holder - Electrical Specifications: Max 14 Volts DC with rated current options of 5Amp, 10Amp, 15Amp, 20Amp, 25Amp, and 30Amp resettable fuse breaker. Perfect for diagnosis of electrical shorts or troubleshooting circuit issues, save from always replaceing fuses
- Compact Dimensions & Universal Compatibility: 12V Breaker's Body height of 1.02 inches( excluding terminals), which is Taller than traditional fuses, more durability and performance. Compatible with 280 Type fuse blocks using 0.32 inch (8.1mm) centerline spacing for easy installation and fuse replacement
- High-Quality Materials: UL-Rated 94V0 thermoplastic body with tin-plated Copper alloy terminals for reliable electrical conductivity and safety
- Wide Applications: The 12 volt auto reset circuit breakers fuses help to troubleshoot electrical problems with automatic recovery functions, and overcurrent protection in 12v DC automotive audio, RVs, trucks, solar systems, caravans, anchors, trolling motors, boat motors, industrial and other applications
- Protect Your System: Nilight thermal circuit breaker can be reset after a disconnect over a period of time, then you can press the reset switch to use it again When load exceeds rated current, the switch reset button will automatically cut off the circuit, and thus play a role in protecting the line.Not designed for push on / push off manual switch operation, but the button pops out at overload and is reset by pushing back in.
- Compact Design: Push-to-reset operation with black manual reset button. This circuit breaker with a waterproof button cap to protect from moisture, water, or bad weather. The hole size for mounting is in 3/8 inch(10mm).This circuit breaker can be used for both AC and DC applications. It's for 125V/250V AC and 65V DC applications.
- High Quality: Our Thermal Circuit Breaker is made of premium bakelite, durable and reliable to use, heat resistant, melting resistance and good conductivity, waterproof cover protect the internal from water and further damage.
- Application: Our circuit breaker compatible with all 12/24V vehicle and 125-250V AC systems industries. Widely used in household and commercial appliances, transportation, marine, telecommunications, power strips, audio-visual, medical, and power supplies
- Package Includes: 5 x 15A Manual Reset Thermal Circuit Breaker, 5 x Hex Nut, 5 x Waterproof Button Caps.
- Type 1: 0.32" (8.1mm) centerline spacing (Mini
Type), 2.8 mm wide blade, compatible with 280 on-vehicle fuse blocks, UL-Rated 94V0 thermoplastic body and Tin-plated Copper alloy terminals - Function:Mini
ATM Auto Reset (T1) Fuses Circuit Breakers is designed to provide overcurrent and short circuit protection, preventing damage to electrical systems and equipment - Perfect Replacement:Each fuses are color-coded on the plastic housing, and the carved amp rating (5A 10A 15A 20A 25A 30A), meets different amperage needs and is also recyclable
- Protect Equipment:Widely used in DC power systems (12V to 14V, maximum DC voltage 14V), marine yacht applications, automotive public transportation, RV systems, etc., which are for the protection of their low voltage equipment
- Wide Application:Suitable RV, Boat, Car, Solar Panels, Truck, Motorcycle, Excavator, etc. Widely apply in a variety of different applications
- FUNCTIONS: Used to protect 12V 24V 36V 48V 60V 100V DC circuit from overload and short circuit damage, and can also be used for control and isolation.
- ARC EXTINGUISHING: This DC mini
circuit breaker has a magnetic system to assist arc extinguishing. - CURVE B: Magnetic trip range 4-7 times rated current.
- APPLICATION: Used in battery power systems, solar photovoltaic systems, RV, electric moped, or other DC systems.
- INSTALLATION: Screw clamps wire or M5 wire lug (size fits), 35 mm DIN rail mount or surface mount.
SEOCONTENT-START
IMPORTANT SAFETY RECALL «OWNER» «STREET» «CITY», «STATE» «ZIP_CODE» This notice applies to your vehicle: «WARRANTY ID» Dear «OWNER»: This notice is sent to you in accordance with the requirements of the National Traffic and Motor Vehicle Safety Act. Cruiser RV
(Cruiser) has decided that a defect which relates to motor vehicle safety exists in certain 2022 Cruiser Shadow Cruiser Travel Trailers manufactured in 2022. We apologize for any inconvenience this action may cause you, however your safety and continued satisfaction are of the utmost importance to us. On certain 2022 Cruiser Shadow Cruiser Travel Trailers, the required 12v mini
breaker cover for the slide out was not installed during production. This has led to exposed studs that could cause arcing. Exposed studs on the mini
breaker can be touched by the aluminum ducting in the area. This could cause arcing and lead to an increased risk of fire and personal injury. Cruiser will have an authorized dealer or repair center inspect the 12 volt mini
breaker for the slide out. If found missing, the dealer will cap the mini
breaker with the proper cap. This repair should take no more than 15 minutes to complete. This defect will be corrected at no expense to you, the owner. All Reimbursements will be covered by Heartland
’s general reimbursement plan. At your earliest convenience, Please contact your local dealer to set up an appointment to have this inspected and if needed corrected immediately, this service will be performed free of charge. You will need the following information for the phone call: • VIN of your travel trailer • Name, Address, and Phone Number If you have questions concerning this recall or if you need any assistance please contact the Warranty/Service Department by phone at 260-562-3500. If you had appropriate repairs completed prior to receipt of this recall notice, and if you incurred any direct cost in connection with obtaining such repair, you may be eligible to receive reimbursement from CRV by contacting the CRV Warranty/Service Department. If after contacting CRV Customer Service you are still not satisfied we have done our best to remedy this situation, you may also submit a written complaint to Transport Canada – Road Safety, 80 rue Noël, Gatineau, Quebec J8Z 0A1 or call 1-800-333-0510. Federal regulations require that any vehicle lessor receiving this recall notice must forward a copy of this notice to the lessee within ten days. Thank you for your attention and cooperation in this matter. Sincerely, CRV Service Department cc: Transport Canada Reason for this recall What we need you to do RECREATIONAL VEHICLE SAFETY RECALL NOTICE NHTSA: 22v306 Cruiser WCC: 99.03.22 Date: What we will do
**************************************************************************************************************
OMB Control No.: 2127-0004 Part 573 Safety Recall Report 22V-306 The information contained in this report was submitted pursuant to 49 CFR §573 Manufacturer Name : Cruiser RV
Submission Date : MAY 06, 2022 NHTSA Recall No. : 22V-306 Manufacturer Recall No. : NR Manufacturer Information : Manufacturer Name : Cruiser RV
Address : 7805 North State Road 9 PO Box 130 Howe IN 46746 Company phone : 866-277-5630 Population : Number of potentially involved : 29 Estimated percentage with defect : 100 % Vehicle Information : Vehicle 1 : 2022-2022 Cruiser Shadow Cruiser Vehicle Type : TRAILERS Body Style : OTHER Power Train : NR Descriptive Information : The population was determined from when the line employee did not install a 12v mini
breaker cover to when it was discovered. Production Dates : MAR 29, 2022 – APR 21, 2022 VIN Range 1 : Begin : 5RXDB3120N1508318 End : 5RXDB3123N1510130 ✔ Not sequential Description of Defect : Description of the Defect : The required 12v mini
breaker cover for the slide-out was not installed during production. This has led to exposed studs that could cause arching. FMVSS 1 : NR FMVSS 2 : NR Description of the Safety Risk : Exposed studs on the mini
breaker can be touched by the aluminum ducting in the area. This could cause arching and lead to an increased risk of fire and personal injury. Description of the Cause : The rubber cover was not installed during production to protect the studs on the 12v mini
breaker. Identification of Any Warning There will be no red rubber cover on the mini
breaker for the slide-out room Part 573 Safety Recall Report 22V-306 Page 2 The information contained in this report was submitted pursuant to 49 CFR §573 that can Occur : located behind the converter. Involved Components : Component Name 1 : Mini
breaker boot Component Description : Red rubber mini
breaker boot Component Part Number : 11131 Boot – VTE-464NOV02 – Rubber Supplier Identification : Component Manufacturer Name : NR Address : NR NR Country : NR Chronology : 4/26/22 received an email from Cruiser Production about missing covers on mini
breakers. 4/27/22 – 4/29/22 Ran warranty claims and determined scope and range. 4/29/22 – called safety committee meeting. 4/30/22 voted to recall. We have had zero warranty claims and zero personal injuries or property damage. Description of Remedy : Description of Remedy Program : Cruiser will have an authorized dealer or repair center inspect the 12-volt mini
breaker for the slide-out. If found missing, the dealer will cap the mini
breaker with the proper cap. This repair should take no more than 15 minutes to complete. This defect will be corrected at no expense to you, the owner. All Reimbursements will be covered by Heartland
’s general reimbursement plan. How Remedy Component Differs The mini
breaker will have rubber boot VTEE-464NOV02 installed. Part 573 Safety Recall Report 22V-306 Page 3 The information contained in this report was submitted pursuant to 49 CFR §573 from Recalled Component : Identify How/When Recall Condition was Corrected in Production : Production began re-installing the cap once the omission was found. Recall Schedule : Description of Recall Schedule : Cruiser will begin notifying owners/dealers once letters are approved Planned Dealer Notification Date : JUL 01, 2022 – JUL 01, 2022 Planned Owner Notification Date : JUL 01, 2022 – JUL 01, 2022 * NR – Not Reported
SEOCONTENT-END