May 18, 2023 NHTSA CAMPAIGN NUMBER: 23V356000
Electrical Short-Circuit in Fuse Box
An electrical short-circuit can increase the risk of a fire.
NHTSA Campaign Number: 23V356
Manufacturer Gillig
, LLC
Components ELECTRICAL SYSTEM
Potential Number of Units Affected 50
Summary
Gillig
, LLC (Gillig
) is recalling certain 2022 Low Floor CNG transit buses. An electrical failure may cause a short-circuit in the fuse box mounted underneath the driver’s seat platform.
Remedy
Gillig
will provide new busbars, free of charge. The manufacturer has not yet provided a schedule for recall notification. Owners may contact Gillig
customer service at 1-510-264-5073 or 1-800-735-1500.
Notes
Owners may also contact the National Highway Traffic Safety Administration Vehicle Safety Hotline at 1-888-327-4236 (TTY 1-800-424-9153), or go to www.nhtsa.gov.
Chronology :
On April 13 2023 during manufacturing, an incomplete vehicle experienced an electrical failure in the fuse box mounted underneath the driver’s platform.
Between April 14 and April 22, GILLIG
conducted an internal analysis to determine the nature of the issue and whether the same event could potentially affect other vehicles. The early findings pointed towards a possible electrical short caused by contact between the 24V busbar and the metal fuse box. Meanwhile, on April 20, out of an abundance of caution, the vehicle customer identified as potentially affected, decided to ground the entire suspect fleet.
On April 24 GILLIG
engineering confirmed the initial observation and determined the issue may be caused by a custom redesign of the low-voltage disconnect switch which may cause excessive preload and subsequent damage of the rubber insulation grommets of the fuse box.
On April 26 GILLIG
completed safety analysis and confirmed the failure mode may potentially affect a limited population of vehicles owned by the customer initially identified.
On May 11 the GILLIG
Safety Committee decided to file a formal safety recall with NHTSA.
As of May 16 2023, GILLIG
is not aware of any other similar event nor injuries potentially related to this condition.
1 Affected Product
Vehicle
| MAKE | MODEL | YEAR |
| GILLIG | LOW FLOOR | 2022 |
4 Associated Documents
Defect Notice 573 Report
RCLRPT-23V356-2217.PDF 215.708KB
Recall Acknowledgement
RCAK-23V356-5554.pdf 645.401KB
Recall 573 Report – 5/23/2023
RCLRPT-23V356-4791.PDF 215.798KB
Recall 573 Report – 5/30/2023
RCLRPT-23V356-7288.PDF 215.799KB
Latest Recalls Documents
- Heavy Duty: This 12V bus bar can handle max operating voltage 48V DC , max continuous amperage: 150A
- Unique Design: 12 stainless M4 terminal screws, 1 x 1/4" (M6) terminal stud & nut for easy installation and route your wires with minimal effort
- What You Get: 1 x positive 12 volt bus bar, 1 x ground 12 volt bus bar, 2 x covers, 2 x 2 AWG 1/4" copper lug and 24 x terminals
- Product Advantage: Thick tinned copper plate busbar, base is made of high quality ABS material, which is mechanically strong, insulated, heat resistant and flame resistant, durable made for safety use
- Wide Application: Using the battery bus bar for wiring can keep the circuit neat and tidy, reducing the possibility of short circuit. Suitable for car, caravan, boat, yacht, solar system, etc
- Robust Terminals & Electrical Ratings: Each busbars 12 volt features 6 x 5/16" (M8) terminal studs. And this power distribution block is capable of handling up to 48V DC, with maximum current 250A
- Unique Round Corner Base Design: The 12V bus bar includes a distinctive round corner base, enhancing both aesthetic appeal and stability of our 12v power distribution block, setting it apart from standard bus bars.
- More Open Area Cover Design: The cover of our battery distribution block allows for 180° wire lug installation, supporting various connection methods, which increases installation flexibility for users.
- Suitable for Extreme Environments: Constructed with copper plates and stainless steel terminals as conductors, this 12v distribution block is designed to perform reliably in harsh conditions, making it ideal for automotive, marine, and other demanding applications.
- Efficient Power Distribution Design: This battery bus bar terminal block 12v comes in pairs, including one positive (red) and one negative (black) bus bar. Also, it is equipped with 12 copper ring lugs and 12 heat shrink tubes for your need, designed for efficient power distribution.
- Upgrade & Thicken: A pair of 12V power distribution block, includes a red and a black power distribution block(Positive&Negative). Our 12V Bus Bar also features 4MM Thicker Copper Bus Bar Plate which can be connected to wider range of cables
- 250A Rating: The power distribution block bus bar rated 250A when work in 12v circuit, and the battery terminal block can handle MAX 48V
- 3/8" Stud: The battery bus bar terminal block includes 4 x 3/8" studs terminal and 3 x #8 screw terminals, which makes the 12V junction block able to accept large size terminal connectors and wires. The nylon bottom is also secured by M10 post which makes it more fixed and won't strip
- Protect Cover and Nuts: Each power busbar will come with a protect cover and two nuts, which helps to shelter as much exposed area as possible to reduce the risks of accidental contact and prevent short circuit, makes the circuit safer
- Wide Application: The 12 volt buss bar with cover aims to make the wiring of circuit become neat and tidy, preventing mess harness from causing electric short circuit, it is suitable for automotive, car, truck, marine, boat, solar wiring
- Heavy-Duty Performance: Solid tinned copper busbar and rigid base for low-resistance battery cable bus bar connections; rated 150 A and up to 48 V for inverters, chargers and DC accessories
- Clear Specs, Right Fit: Measures approx. 5.4" L with cover, 4.7" base length, 0.9" W and 0.5" H; includes 1/4" studs and 12 terminals, please confirm mounting space and cable clearance before purchase
- Secure Locking Covers: Snap-lock covers fit tight to resist vibration; helps reduce accidental contact and shorts at the terminal block power junction block; keeps connections covered during service and transport
- Clean, Professional Wiring: Central battery power distribution block consolidates multiple leads; reduces cluttered battery posts and wiring errors; simplifies troubleshooting for solar, marine and automotive wiring
- Versatile DC Applications: Use as a 12 V bus bar, marine bus bar or ground bus bar; supports RV, boat, truck, UTV and off-road builds; practical battery distribution block for fuse blocks, lighting, winches and audio
- Superior Quality: These 12v bus bars are composed of tin plated copper bar, stainless steel nuts and stud terminals, nylon bus bar terminal block base and polycarbonate cover, reliable and solid for use.
- 5/16" Terminal Studs: The terminal of this marine bus bar is 5/16" (M8) terminal stud design, is capable of larger size wire lug installation, makes it sufficient to support safe use of rated current and voltage.
- Rating: This 150A bus bar terminal block can work in Max 300V AC, 48V DC power supply curcuits, and its size is smaller than other normal 150A bus bars, can meet various mounting demands.
- Convenient Connection: This battery terminal block has reasonable spacing for connector installation, in addition, the side posts allows max 180° direction wire installation, can meet a wider range of installation demands.
- Wide Application: The high-quality materials of this battery distribution block enables it to work in extreme environments, universally fit for automotive, car, boat, solar systems, etc.
Last update on 2026-05-27 / Affiliate links / Images from Amazon Product Advertising API
SEOCONTENT-START
OMB Control No.: 2127-0004 Part 573 Safety Recall Report 23V-356 The information contained in this report was submitted pursuant to 49 CFR §573 Manufacturer Name : Gillig
, LLC Submission Date : MAY 18, 2023 NHTSA Recall No. : 23V-356 Manufacturer Recall No. : NR Manufacturer Information : Manufacturer Name : Gillig
, LLC Address : 451 Discovery Drive LIVERMORE CA 94551 Company phone : 1-800-735-1500 Population : Number of potentially involved : 50 Estimated percentage with defect : 100 % Vehicle Information : Vehicle 1 : 2022-2022 GILLIG
LOW FLOOR CNG Vehicle Type : BUSES, MEDIUM & HEAVY VEHICLES Body Style : ALL Power Train : CNG/LPG Descriptive Information : Metal-to-metal contact may cause an electrical short in the vehicle fuse box. Production Dates : AUG 10, 2022 – DEC 01, 2022 VIN Range 1 : Begin : 15GGD3115N3196740 End : 15GGD3112N3196789 ✔ Not sequential Description of Defect : Description of the Defect : GILLIG
has determined that a limited population of CNG vehicles is affected by a defect that may cause an electrical failure in the fuse box mounted underneath the driver’s platform. The insulation of the red 24V busbar may become compromised due to excessive preload pinching the rubber grommet between the copper busbar and the steel fuse box. The resulting electrical short may cause a thermal event thus increasing the risk of vehicle fire. As a result of the above, GILLIG
has decided to voluntarily initiate a safety recall campaign for the vehicle population that may be affected by the issue. Only one customer is affected by this recall. FMVSS 1 : NR FMVSS 2 : NR Description of the Safety Risk : A thermal event with increased risk of vehicle fire Description of the Cause : NR Identification of Any Warning that can Occur : GILLIG
is not aware of any driver’s warning prior to failure. Involved Components : Part 573 Safety Recall Report 23V-356 Page 2 The information contained in this report was submitted pursuant to 49 CFR §573 Component Name 1 : NR Component Description : NR Component Part Number : NR Supplier Identification : Component Manufacturer Name : NR Address : NR NR Country : NR Chronology : On April 13 2023 during manufacturing, an incomplete vehicle experienced an electrical failure in the fuse box mounted underneath the driver’s platform. Between April 14 and April 22, GILLIG
conducted an internal analysis to determine the nature of the issue and whether the same event could potentially affect other vehicles. The early findings pointed towards a possible electrical short caused by contact between the 24V busbar and the metal fuse box. Meanwhile, on April 20, out of an abundance of caution, the vehicle customer identified as potentially affected, decided to ground the entire suspect fleet. On April 24 GILLIG
engineering confirmed the initial observation and determined the issue may be caused by a custom redesign of the low-voltage disconnect switch which may cause excessive preload and subsequent damage of the rubber insulation grommets of the fuse box. On April 26 GILLIG
completed safety analysis and confirmed the failure mode may potentially affect a limited population of vehicles owned by the customer initially identified. On May 11 the GILLIG
Safety Committee decided to file a formal safety recall with NHTSA. As of May 16 2023, GILLIG
is not aware of any other similar event nor injuries potentially related to this condition. Part 573 Safety Recall Report 23V-356 Page 3 The information contained in this report was submitted pursuant to 49 CFR §573 Description of Remedy : Description of Remedy Program : The remedy consists of a redesign of the 12 and 24V busbars that eliminates excessive pinch of the rubber grommets and ensures appropriate electrical isolation. Pursuant to 49 CFR 577.11(e), GILLIG
requests that it be exempt from providing notification of a reimbursement plan. Any pre-notification product failure would have been addressed under the manufacturer’s limited warranty. Accordingly, no person would be eligible for reimbursement pursuant to 573.13. How Remedy Component Differs from Recalled Component : New 12V and 24V busbar parts. Identify How/When Recall Condition was Corrected in Production : All current production buses with a similar low-voltage disconnect design will be updated with the new parts. Recall Schedule : Description of Recall Schedule : GILLIG
plans to send out the owner’s notification letters by the end of the 60-day period from the date this recall is filed. GILLIG
does not have a dealer network and, therefore, a dealer’s notification is not required. Planned Dealer Notification Date : NR – NR Planned Owner Notification Date : NR – NR * NR – Not Reported
**************************************************************************************************************
OMB Control No.: 2127-0004 Part 573 Safety Recall Report 23V-356 The information contained in this report was submitted pursuant to 49 CFR §573 Manufacturer Name : Gillig
, LLC Submission Date : MAY 30, 2023 NHTSA Recall No. : 23V-356 Manufacturer Recall No. : NR Manufacturer Information : Manufacturer Name : Gillig
, LLC Address : 451 Discovery Drive LIVERMORE CA 94551 Company phone : 1-800-735-1500 Population : Number of potentially involved : 30 Estimated percentage with defect : 100 % Vehicle Information : Vehicle 1 : 2022-2022 GILLIG
LOW FLOOR CNG Vehicle Type : BUSES, MEDIUM & HEAVY VEHICLES Body Style : ALL Power Train : CNG/LPG Descriptive Information : Metal-to-metal contact may cause an electrical short in the vehicle fuse box. Production Dates : AUG 10, 2022 – DEC 01, 2022 VIN Range 1 : Begin : 15GGD3115N3196740 End : 15GGD3112N3196789 ✔ Not sequential Description of Defect : Description of the Defect : GILLIG
has determined that a limited population of CNG vehicles is affected by a defect that may cause an electrical failure in the fuse box mounted underneath the driver’s platform. The insulation of the red 24V busbar may become compromised due to excessive preload pinching the rubber grommet between the copper busbar and the steel fuse box. The resulting electrical short may cause a thermal event thus increasing the risk of vehicle fire. As a result of the above, GILLIG
has decided to voluntarily initiate a safety recall campaign for the vehicle population that may be affected by the issue. Only one customer is affected by this recall. FMVSS 1 : NR FMVSS 2 : NR Description of the Safety Risk : A thermal event with increased risk of vehicle fire Description of the Cause : NR Identification of Any Warning that can Occur : GILLIG
is not aware of any driver’s warning prior to failure. Involved Components : Part 573 Safety Recall Report 23V-356 Page 2 The information contained in this report was submitted pursuant to 49 CFR §573 Component Name 1 : Busbar Component Description : Low-voltage 12V busbar Component Part Number : 13-57847-013 Component Name 2 : Busbar Component Description : Low-voltage 24V busbar Component Part Number : 13-57847-012 Supplier Identification : Component Manufacturer Name : NR Address : NR NR Country : NR Chronology : On April 13 2023 during manufacturing, an incomplete vehicle experienced an electrical failure in the fuse box mounted underneath the driver’s platform. Between April 14 and April 22, GILLIG
conducted an internal analysis to determine the nature of the issue and whether the same event could potentially affect other vehicles. The early findings pointed towards a possible electrical short caused by contact between the 24V busbar and the metal fuse box. Meanwhile, on April 20, out of an abundance of caution, the vehicle customer identified as potentially affected, decided to ground the entire suspect fleet. On April 24 GILLIG
engineering confirmed the initial observation and determined the issue may be caused by a custom redesign of the low-voltage disconnect switch which may cause excessive preload and subsequent damage of the rubber insulation grommets of the fuse box. On April 26 GILLIG
completed safety analysis and confirmed the failure mode may potentially affect a limited population of vehicles owned by the customer initially identified. On May 11 the GILLIG
Safety Committee decided to file a formal safety recall with NHTSA. As of May 16 2023, GILLIG
is not aware of any other similar event nor injuries potentially related to this condition. Part 573 Safety Recall Report 23V-356 Page 3 The information contained in this report was submitted pursuant to 49 CFR §573 Description of Remedy : Description of Remedy Program : The remedy consists of a redesign of the 12 and 24V busbars that eliminates excessive pinch of the rubber grommets and ensures appropriate electrical isolation. Pursuant to 49 CFR 577.11(e), GILLIG
requests that it be exempt from providing notification of a reimbursement plan. Any pre-notification product failure would have been addressed under the manufacturer’s limited warranty. Accordingly, no person would be eligible for reimbursement pursuant to 573.13. How Remedy Component Differs from Recalled Component : New 12V and 24V busbar parts. Identify How/When Recall Condition was Corrected in Production : All current production buses with a similar low-voltage disconnect design will be updated with the new parts. Recall Schedule : Description of Recall Schedule : GILLIG
plans to send out the owner’s notification letters by the end of the 60-day period from the date this recall is filed. GILLIG
does not have a dealer network and, therefore, a dealer’s notification is not required. Planned Dealer Notification Date : NR – NR Planned Owner Notification Date : NR – NR * NR – Not Reported
**************************************************************************************************************
OMB Control No.: 2127-0004 Part 573 Safety Recall Report 23V-356 The information contained in this report was submitted pursuant to 49 CFR §573 Manufacturer Name : Gillig
, LLC Submission Date : MAY 23, 2023 NHTSA Recall No. : 23V-356 Manufacturer Recall No. : NR Manufacturer Information : Manufacturer Name : Gillig
, LLC Address : 451 Discovery Drive LIVERMORE CA 94551 Company phone : 1-800-735-1500 Population : Number of potentially involved : 50 Estimated percentage with defect : 100 % Vehicle Information : Vehicle 1 : 2022-2022 GILLIG
LOW FLOOR CNG Vehicle Type : BUSES, MEDIUM & HEAVY VEHICLES Body Style : ALL Power Train : CNG/LPG Descriptive Information : Metal-to-metal contact may cause an electrical short in the vehicle fuse box. Production Dates : AUG 10, 2022 – DEC 01, 2022 VIN Range 1 : Begin : 15GGD3115N3196740 End : 15GGD3112N3196789 ✔ Not sequential Description of Defect : Description of the Defect : GILLIG
has determined that a limited population of CNG vehicles is affected by a defect that may cause an electrical failure in the fuse box mounted underneath the driver’s platform. The insulation of the red 24V busbar may become compromised due to excessive preload pinching the rubber grommet between the copper busbar and the steel fuse box. The resulting electrical short may cause a thermal event thus increasing the risk of vehicle fire. As a result of the above, GILLIG
has decided to voluntarily initiate a safety recall campaign for the vehicle population that may be affected by the issue. Only one customer is affected by this recall. FMVSS 1 : NR FMVSS 2 : NR Description of the Safety Risk : A thermal event with increased risk of vehicle fire Description of the Cause : NR Identification of Any Warning that can Occur : GILLIG
is not aware of any driver’s warning prior to failure. Involved Components : Part 573 Safety Recall Report 23V-356 Page 2 The information contained in this report was submitted pursuant to 49 CFR §573 Component Name 1 : Busbar Component Description : Low-voltage 12V busbar Component Part Number : 13-57847-013 Component Name 2 : Busbar Component Description : Low-voltage 24V busbar Component Part Number : 13-57847-012 Supplier Identification : Component Manufacturer Name : NR Address : NR NR Country : NR Chronology : On April 13 2023 during manufacturing, an incomplete vehicle experienced an electrical failure in the fuse box mounted underneath the driver’s platform. Between April 14 and April 22, GILLIG
conducted an internal analysis to determine the nature of the issue and whether the same event could potentially affect other vehicles. The early findings pointed towards a possible electrical short caused by contact between the 24V busbar and the metal fuse box. Meanwhile, on April 20, out of an abundance of caution, the vehicle customer identified as potentially affected, decided to ground the entire suspect fleet. On April 24 GILLIG
engineering confirmed the initial observation and determined the issue may be caused by a custom redesign of the low-voltage disconnect switch which may cause excessive preload and subsequent damage of the rubber insulation grommets of the fuse box. On April 26 GILLIG
completed safety analysis and confirmed the failure mode may potentially affect a limited population of vehicles owned by the customer initially identified. On May 11 the GILLIG
Safety Committee decided to file a formal safety recall with NHTSA. As of May 16 2023, GILLIG
is not aware of any other similar event nor injuries potentially related to this condition. Part 573 Safety Recall Report 23V-356 Page 3 The information contained in this report was submitted pursuant to 49 CFR §573 Description of Remedy : Description of Remedy Program : The remedy consists of a redesign of the 12 and 24V busbars that eliminates excessive pinch of the rubber grommets and ensures appropriate electrical isolation. Pursuant to 49 CFR 577.11(e), GILLIG
requests that it be exempt from providing notification of a reimbursement plan. Any pre-notification product failure would have been addressed under the manufacturer’s limited warranty. Accordingly, no person would be eligible for reimbursement pursuant to 573.13. How Remedy Component Differs from Recalled Component : New 12V and 24V busbar parts. Identify How/When Recall Condition was Corrected in Production : All current production buses with a similar low-voltage disconnect design will be updated with the new parts. Recall Schedule : Description of Recall Schedule : GILLIG
plans to send out the owner’s notification letters by the end of the 60-day period from the date this recall is filed. GILLIG
does not have a dealer network and, therefore, a dealer’s notification is not required. Planned Dealer Notification Date : NR – NR Planned Owner Notification Date : NR – NR * NR – Not Reported
**************************************************************************************************************
**************************************************************************************************************
SEOCONTENT-END
This product presentation was made with AAWP plugin.