191125REV – Generator Exhaust Pipe may get Damaged – 2016-2020 Fleetwood Bounder, Holiday Rambler Vacationer, 2018-2020 Fleetwood Southwind Motorhomes

December 4, 2019 NHTSA CAMPAIGN NUMBER: 19V860000

Generator Exhaust Pipe may get Damaged

If the generator exhaust pipe is damaged, it may cause carbon monoxide to enter the vehicle, increasing the risk of an injury or death.

 

NHTSA Campaign Number: 19V860

Manufacturer REV Recreation Group

Components EQUIPMENT

Potential Number of Units Affected 3,241

 

Summary

REV Recreation Group (REV) is recalling certain 2016-2020 Fleetwood Bounder, Holiday RamblereBay logo Vacationer, and 2018-2020 Fleetwood Southwind motorhomes. The generator exhaust pipe placement exits the motorhome within the vehicle’s departure angle.

 

Remedy

REV will notify owners, and dealers will inspect, replace and reroute the generator exhaust pipe, free of charge. The recall began January 30, 2020. Owners may contact REV customer service at 1-800-509-3417. REV’s number for this recall is 191125REV.

 

Notes

Owners may also contact the National Highway Traffic Safety Administration Vehicle Safety Hotline at 1-888-327-4236 (TTY 1-800-424-9153), or go to www.safercar.gov.

 


Recall Bulletin 191125REV

RECALL BULLETIN:

191125REV

 

YEAR(S) AFFECTED:

2016-2020

 

PRODUCT(S) AFFECTED:

2016-2020 Fleetwood Bounder manufactured 3/20/2015 through 7/31/2019

2018-2020 Fleetwood Southwind manufactured 7/18/2017 through 7/24/2019

2016-2020 Holiday RamblereBay logo Vacationer manufactured 07/13/2015 through 07/31/2019

 

MODEL(S) AFFECTED:

See Affected Models at above right, paragraph 2

 

SUBJECT:

Inspection / Correction of Generator Exhaust Pipe Routing

 

KEYWORDS:

Exhaust, Generator

 

ISSUE DATE:

January 2020

 

The purpose of this Recall Service Bulletin is to inform all REV Recreation Group dealers about the need to inspect the generator exhaust pipe routing on certain model year 2016-2020 Fleetwood Bounder, certain model year 2018-2020 Fleetwood Southwind and certain model year 2016-2020 Holiday RamblereBay logo Vacationer motorhomes, to ensure the exhaust pipe does not intrude into the departure angle of the coach. If the generator exhaust pipe is improperly routed, it will need to be replaced with a different exhaust pipe.

Affected Models: 33C, 33CT, 34C, 34ST, 34T, 35K, 35DK, 35P, 36E, 36H, 36P, 36X, 36Y, 37BH and 37H. No other models are affected.

The lists of affected motorhomes and required replacement parts appear at the end of this Bulletin.

 

CONDITION:

Motorhomes affected by this recall may have the generator exhaust pipe routed in a manner that causes it to exit within the departure angle. This could cause the exhaust pipe to become damaged or sheared off if the vehicle is driven on an incline, potentially allowing carbon monoxide from generator exhaust emissions to enter the vehicle, which could result in illness or death.

 

PROCEDURES:

Dealers are required obtain Prior Authorization and to call REV Dealer Technical Support to before beginning any work and after the unit is in their bay. You will receive instructions and will be provided any necessary part ordering information.

Fleetwood Dealer Technical Support: (800) 816-9825

Holiday RamblereBay logo Dealer Technical Support: (877) 332-9239

  • READ THIS ENTIRE BULLETIN CAREFULLY BEFORE PROCEEDING AND FOLLOW ALL SAFETY PRECAUTIONS.
  • Review the list of affected units at the end of this bulletin to ensure the motorhome you are inspecting is part of this campaign.
  • Take a copy of this bulletin with you when servicing the unit.
  • PHOTOS WILL BE REQUIRED FOR THE FOLLOWING PROCEDURES. READ PHOTO REQUIREMENTS CAREFULLY. INSUFFICIENT PHOTO DOCUMENTATION MAY RESULT IN CLAIM DENIAL
  • If there are any questions after reviewing the entire procedure, contact REV Dealer Technical Support.

 

WARNING

  • KEEP CLEAR OF ALL PINCH POINTS WHEN WORKING UNDER A MOTORHOME. THE LEVELING JACKS SHOULD NOT SUPPORT ANY WEIGHT OF THE MOTORHOME WHILE WORK IS PERFORMED. FAILURE TO FOLLOW THIS WARNING MAY RESULT IN PERSONAL INJURY.
  • DO NOT WORK UNDER AN ELEVATED MOTORHOME UNLESS IT IS SUPPORTED BY A HOIST OR WITH JACK STANDS CAPABLE OF SUPPORTING ITS WEIGHT.
  • HEED ALL PRECAUTIONS AND USE APPROPRIATE PERSONAL PROTECTIVE EQUIPMENT TO AVOID INJURY.

 

IMPORTANT NOTE:

This procedure contains the evaluation and repair for two distinctly different floor plan groups, 35P/36P models and non-35/36P models.

Please verify which floor plan you are working on prior to proceeding.

 

INSPECTION / EVALUATION – ALL MODELS

1. Park the motorhome on dry, level pavement. Place the transmission into PARK and set the parking brake.

2. Turn off the ignition and remove the ignition key. Maintain control of the ignition key until all repairs are completed. Attach a notice, “DO NOT USE”, to the generator switch in order to avoid activation of the system.

3. Block wheels to prevent movement.

4. Locate the generator exhaust pipe on the driver’s side rear area of the coach, and determine whether it exits in the area of the departure angle by using the following string method:

a) Using a heavy gauge string (e.g. chalk line or mason line), wedge or hook one end under the point where the rear tire contacts the ground.

b) Have an assistant pull the string tight and hold it against the lowest point on the trailer hitch skid plate; see Figure 1.

This will create a wedge with the ground surface as shown in Figure 2. The gray shaded area is
the departure angle.

c) Bend or squat down and look at the generator exhaust at eye level.

IMPORTANT: Observing this area at eye level is critical to the evaluation.

d) While at eye level, observe whether the generator pipe is above the departure angle (above the string) or in the departure angle (below the string). Refer to Figure 2.

SEE NEXT PAGE FOR PHOTO REQUIREMENTS

 

PHOTO REQUIREMENTS

5. Kneel down and take several photos of the generator exhaust pipe location both from the eye level view as well as from slightly below the coach, clearly showing whether the exhaust pipe exits within the departure angle. Be sure at least one photograph includes the area from the centerline of the rear tire to the rear bumper.

Refer to Figure 2 on the previous page for examples of proper and improper routing.

a) If the evaluation shows that the generator exhaust pipe is not in the departure angle, the photos must be submitted with the repair claim in REV RV’s warranty portal; use flat rate code 6090-11, “Inspected/Not Defective”. No further work is required.

b) If the evaluation shows that the generator exhaust pipe is in the departure angle, it will need to be replaced. “Before” and “after” photos will be required. Take several clear photos prior to beginning repairs showing the improper routing; the photos must be attached to a draft claim in the dealer warranty portal (A.D.N.). After receiving approval to proceed with repairs, perform the Repair Procedure beginning at Step 6.

After completing repairs, take several photos that clearly display the corrected routing of the generator exhaust. Both sets of photos (“before” and “after”) must be attached to the repair claim in REV RV’s warranty portal; use flat rate code 6090-12, “Inspected/Defective/Repaired”.

 

REPAIR PROCEDURE                                                                         

 

6. Referring to Figure 3, find and remove the generator exhaust hanger bracket located near the sidewall. After the exhaust hanger is loose from the pipe, locate the upper  fastener securing the hanger to the coach. Remove it and set the exhaust hanger aside for possible reinstallation.

7. With the exhaust hanger removed, locate and remove the fasteners holding the exhaust guard to the motorhome. See Figure 4. Set the exhaust guard aside for possible reinstallation.

Note: If the exhaust guard is damaged or missing it will need to be replaced. See part ordering information on Page 9 of the bulletin.

8. At the generator, use a ratchet and socket to remove the U-bolt exhaust clamp that holds the generator exhaust pipe to the generator flange. See Figure 5.

9. For 35P & 36P models only:
If equipped, remove the heat shield retaining U-bolts in order to release the plumbing strap exhaust hangers. Also, locate and remove the upper fastener(s) attaching the plumber’s strap to the chassis framework.

10. With all of the fasteners and hardware removed, detach the generator exhaust pipe from the coach. Retain the flat washers for reuse in a later step. Dispose of the exhaust pipe, bolts and locknuts. Also dispose of the heat shield and its fasteners. A heat shield will not be required for use with the replacement exhaust pipe specified in the Parts list (page 9) for Model(s) 35P or 36P.

 

Based on the model of coach you are working on, refer to the following specifications to identify which remaining repair steps must be followed:

  • All models except 35P & 36P – Perform Steps 11-16
  • Models 35P & 36P only – Perform Steps 17-24

 

Repair Steps for all affected models other than 35P and 36P Ensure all needed parts are on hand before beginning. Refer to Parts List “A” on Page 9.

11. Begin reinstallation by installing the new exhaust heat shield onto the new generator exhaust pipe using (two) 1 ½” I.D. exhaust clamps in the location shown in Figure 6.

12. With the heat shield in place, slide the new generator exhaust pipe onto the generator exhaust port until it is fully seated to the bottom of the flared end or is tight against the bottom of the generator. Be sure it is oriented so that it exits the side of the motorhome under the luggage door. Clamp in place with the U-bolt exhaust clamp previously removed; take care to position the U-bolt so that the nuts can be easily tightened with a ratchet and a ½” deep well socket. Reference Figures 7 and 8.

13. With the luggage door open, attach the generator exhaust hanger removed in Step 6 to the generator exhaust pipe using the original hardware. Once attached to the generator exhaust pipe, use a
1/4-20 X 1” HWH self-drilling screw to secure the exhaust hanger to the square steel tube located behind the luggage door fascia. Verify the pipe is mounted in a location that will allow the luggage door to close without contacting the exhaust pipe. Refer to Figure 9.

14. Before proceeding, verify that the generator exhaust pipe protrudes past the vertical surface of the luggage door(s) by a minimum of 1”. See Figure 10. Adjust as needed to achieve proper spacing.

15. Once the proper clearances are verified, install the generator exhaust guard that was removed in Step 7 using 1/4-20 X 1” HWH self-drilling screws. It may be required to bend the mounting tabs to 90° as this will be attached to the underside of the steel tube located behind the luggage door fascia as shown in Figure 11.

16. Close and reopen the luggage door to verify that there are no interferences; adjust as needed. If no interferences are identified, the repair is complete.

PHOTO REQUIREMENT: When the repair has been completed, kneel down and take several photos that clearly show that the generator exhaust pipe has been properly routed. Be sure at least one photograph includes the area from the centerline of the rear tire to the rear bumper. Refer to Figure 2, “Acceptable Routing” examples, on Page 3. The photos must be attached to the repair claim.

 

Repair Steps for Models 35P and 36P only

Ensure all needed parts are on hand before beginning. Refer to Parts List “B” on Page 9.

17. Begin reinstallation by sliding the new generator exhaust pipe onto the generator exhaust port until it is fully seated to the bottom of the flared end or is tight against the bottom of the generator. Be sure it is oriented so that it exits the side of the motorhome, under the luggage door. Clamp in place with the U-bolt exhaust clamp previously removed; take care to position the U-bolt so that the nuts can be easily tightened with a ratchet and a ½” deep well socket. Reference Figures 12 and 13.

18. With the luggage door open, use the generator exhaust hanger removed in Step 6 as a template to locate and drill a 5/16” hole above the generator exhaust pipe in the metal luggage door fascia as shown in Figure 14.

19. Move the generator exhaust hanger behind the metal luggage door fascia and secure it in place with a 1/4 – 20 x 1 bolt and lock nut, using 1/4” flat washers on the inner and outer surfaces of the union.

20. Finish installing the generator exhaust hanger by installing the bottom portion of the hanger around the generator exhaust pipe.

21. Close and reopen the luggage door to verify that there are no interferences; adjust as needed.

22. With the luggage door open, using the exhaust guard removed in Step 7 as a template, mark and drill (two) 5/16” holes in the metal luggage door fascia. Refer to Figure 14.

23. Move the generator exhaust guard behind the metal luggage door fascia and secure it in place with (2) 1/4 – 20 x 1 bolts and lock nuts, using 1/4” flat washers on the inner and outer surfaces of the unions.

24. Close and reopen the luggage door to verify that there are no interferences, adjust as needed. If no interferences are identified, the repair is complete.

 

PHOTO REQUIREMENT: When the repair has been completed, kneel down and take several photos that clearly show that the generator exhaust pipe has been properly routed. Be sure at least one photograph includes the area from the centerline of the rear tire to the rear bumper. Refer to Figure 2, “Acceptable Routing” examples, on Page 3. The photos must be attached to the repair claim.

 

TOOLS

Wheel Chocks Power Driver Driver Bits

½” Open End Wrench

½” Socket Ratchet Flashlight

 

PARTS

Order only the part numbers listed below that pertain to the model of vehicle with which you are working:

 Parts List “A” – Applies to All Affected Models Other Than 35P and 36P: 

Part NumberDescriptionQty,.
10787563 (ref. B65-0135)Generator Exhaust Pipe1 ea.
10789669 (ref. B85-0646)Generator Exhaust Heat Shield1 ea.
10124615 (ref. L50-0998)Exhaust Clamp3 ea.
10089470 (ref. M66-1407)Screw-Tek 1/4-20 X 1 HWH Pltd3 ea.
Order only if original parts are damaged or missing:
10006666 (L50-0010)Exhaust Hanger1 ea.
10005580 (ref. F76-0373 )Exhaust Guard1 ea.

 

 

 Parts List “B” – Applies to Model 35P or 36P only:

Part NumberDescriptionQty,
10774830 (ref. B65-0132)Generator Exhaust Pipe1 ea.
10007182 (ref. M06-1008)1/4-20 x 1” Bolts3 ea.
10007303 (ref. M22-1010)1/4-20 Lock Nuts3 ea.
Order only if original parts are damaged or missing:
10006666 (ref. L50-0010)Exhaust Hanger1 ea.
10005580 (ref. F76-0373)Exhaust Guard1 ea.

 

 

WARRANTY LABOR ALLOWANCE:

6090-11Inspected/Not Defective0.2 hr.Prior Authorization & Photos Required
6090-12Inspected/Defective/Repaired0.6 hr.Prior Authorization & “Before” and
“After” Photos Required

 

Recall 191125REV, Bounder/Southwind/Vacationer Generator Exhaust Routing Use flat rate codes:

 

If you have any questions concerning this bulletin, contact REV Dealer Technical Support:

Fleetwood Dealer Technical Support: (800) 816-9825 Holiday RamblereBay logo Dealer Technical Support: (877) 332-9239

 

Service Literature is available at: https://www.revrvdealers.com

 


IMPORTANT SAFETY RECALL

RECALL 191125REV
NHTSA # 19V860
Second Notice – June 2020
THIS NOTICE APPLIES TO YOUR VEHICLE

 

VIN: <<VIN>>

Model Year <<YEAR>> <<PRODUCT>> <<MODEL>> REV RV Serial No: <<UIN>>

Dear Valued Holiday RamblereBay logo Customer:

This notice is sent to you in accordance with the requirements of the National Traffic and Motor Vehicle Safety Act.

REV Recreation Group Inc. has decided that a safety defect relating to motor vehicle safety exists in certain model year 2016-2020 Holiday RamblereBay logo brand Vacationer Class A gas motorhomes manufactured July 13, 2015 through July 24, 2019.

 

WHAT IS THE PROBLEM?

On motorhomes affected by this recall, the generator exhaust pipe may be routed to exit the motorhome within its departure angle. This could cause the exhaust pipe to become damaged or sheared off if the vehicle is driven on an incline.

If the generator exhaust pipe is damaged or sheared off, it may cause carbon monoxide to intrude inside the vehicle, which could result in illness or death.

 

WHAT SHOULD YOU DO?

Please make certain your motorhome is immediately inspected and repaired by contacting an authorized REV Recreation Group Inc. dealer.

For assistance locating an authorized REV Recreation Group servicing dealer, please call REV Recreation Group Owner Relations toll-free at:

(800) 322-8216

 

WHAT WILL REV RECREATION GROUP DO?

With your continued satisfaction in mind, it is our intention to have these repairs made at your convenience with as little disruption as possible. Effective immediately, REV RV dealers have been supplied with all of the information needed to enable them to inspect, and if necessary, replace the generator exhaust pipe and properly route it.

The repair should take less than one hour to complete; however, because of service scheduling times, your dealer may need the vehicle for a longer period of time. This service will be performed for you free of charge.

When you deliver your motorhome for repairs, your dealer will complete a Repair Order. Upon completion of the repair, please sign the Repair Order and fi ll out the enclosed self-addressed Vehicle/Owner Information Update Card and return it to REV Recreation Group.

If you have changed your address or sold the motorhome, please take a moment to provide the name and address of the person or dealership you sold it to on the enclosed Vehicle/Owner Information Update Card and return it to REV Recreation Group. This will allow us to update our records and if necessary, notify the new owner using the information you provide.

Alternately, you may use a smart device and the QR code at right to navigate to the online owner update form, or visit: https://www.holidayrambler.com/change-of-ownership

If you have paid to have this concern corrected previously, you may be eligible for reimbursement of your cost for that repair. For more information, please contact REV Recreation Group Owner Relations at (800) 322-8216.

For more information regarding this recall, contact:

REV RECREATION GROUP OWNER RELATIONS – RECALL #191125REV
P.O. Box 1007
Decatur, Indiana 46733
(800) 322-8216

If you are unable to obtain the specified repair promptly and without charge, please contact REV Recreation Group Owner Relations using the above information.

If you believe that the dealer and REV Recreation Group Inc. have failed or have been unable to remedy the defect without charge or within a reasonable period of time, you may submit a complaint to:

Administrator
National Highway Traffic Safety Administration
1200 New Jersey Avenue, S.E.
Washington, DC 20590

Or call the toll-free Vehicle Safety Hotline at 1-888-327-4236
(TTY: 1-800-424-9153)
or go to https://www.safercar.gov

 

REV Recreation Group Inc. is taking these steps in the interest of your safety. We regret any inconvenience this may cause you.

Sincerely,

 

REV RECREATION GROUP INC.

 


IMPORTANT SAFETY RECALL

RECALL 191125REV
NHTSA # 19V860
January 2020
THIS NOTICE APPLIES TO YOUR VEHICLE

 

VIN: 

Model Year HOLIDAY RAMBLEReBay logo VACATIONER  Model REV RV Serial no:

Dear Valued Holiday RamblereBay logo Customer:

This notice is sent to you in accordance with the requirements of the National Traffic and Motor Vehicle Safety Act.

REV Recreation Group Inc. has decided that a safety defect relating to motor vehicle safety exists in certain model year 2016-2020 Holiday RamblereBay logo brand Vacationer Class A gas motorhomes manufactured July 13, 2015 through July 24, 2019.

 

WHAT IS THE PROBLEM?

On motorhomes affected by this recall, the generator exhaust pipe may be routed to exit the motorhome within its departure angle. This could cause the exhaust pipe to become damaged or sheared off if the vehicle is driven on an incline.

If the generator exhaust pipe is damaged or sheared off, it may cause carbon monoxide to intrude inside the vehicle, which could result in illness or death.

 

WHAT SHOULD YOU DO?  

Please make certain your motorhome is immediately inspected and repaired by contacting an authorized REV Recreation Group Inc. dealer.

For assistance locating an authorized REV Recreation Group servicing dealer, please call REV Recreation Group Owner Relations toll-free at:

(800) 322-8216

 

WHAT WILL REV RECREATION GROUP DO?

With your continued satisfaction in mind, it is our intention to have these repairs made at your convenience with as little disruption as possible. Effective immediately, REV RV dealers have been supplied with all of the information needed to enable them to inspect, and if necessary, replace the generator exhaust pipe and properly route it.

The repair should take less than one hour to complete; however, because of service scheduling times, your dealer may need the vehicle for a longer period of time. This service will be performed for you free of charge.

When you deliver your motorhome for repairs, your dealer will complete a Repair Order. Upon completion of the repair, please sign the Repair Order and fill out the enclosed self-addressed Vehicle/Owner Information Update Card and return it to REV Recreation Group.

If you have changed your address or sold the motorhome, please take a moment to provide the name and address of the person or dealership you sold it to on the enclosed Vehicle/Owner Information Update Card and return it to REV Recreation Group. This will allow us to update our records and if necessary, notify the new owner using the information you provide.

If you have paid to have this concern corrected previously, you may be eligible for reimbursement of your cost for that repair. For more information, please contact REV Recreation Group Owner Relations at (800) 322-8216.

 

For more information regarding this recall, contact:

REV RECREATION GROUP OWNER RELATIONS – RECALL #191125REV
P.O. Box 1007
Decatur, Indiana 46733
(800) 322-8216

 

If you are unable to obtain the specified repair promptly and without charge, please contact REV Recreation Group Owner Relations using the above information.

If you believe that the dealer and REV Recreation Group Inc. have failed or have been unable to remedy the defect without charge or within a reasonable period of time, you may submit a complaint to:

Administrator
National Highway Traffic Safety Administration
1200 New Jersey Avenue, S.E.
Washington, DC 20590

 

Or call the toll-free Vehicle Safety Hotline at 1-888-327-4236
(TTY: 1-800-424-9153)
or go to https://www.safercar.gov

 

REV Recreation Group Inc. is taking these steps in the interest of your safety. We regret any inconvenience this may cause you.

Sincerely,

 

REV RECREATION GROUP INC.

 


IMPORTANT SAFETY RECALL

RECALL 191125REV
NHTSA # 19V860
Second Notice – June 2020
THIS NOTICE APPLIES TO YOUR VEHICLE

 

VIN: <<VIN>>

Model Year   <<YEAR>> <<PRODUCT>> <<MODEL>> REV RV Serial No: <<UIN>>

Dear Valued Fleetwood Customer:

This notice is sent to you in accordance with the requirements of the National Traffi c and Motor Vehicle Safety Act.

REV Recreation Group Inc. has decided that a safety defect relating to motor vehicle safety exists in certain model year 2016-2020 Fleetwood brand Class A gas motorhomes:

Model year 2016-2020 Bounder – Manufactured March 20, 2015 – July 31, 2019

Model year 2018-2020 Southwind  –  Manufactured July 18, 2017 – July 24, 2019

 

WHAT IS THE PROBLEM?

On motorhomes affected by this recall, the generator exhaust pipe may be routed to exit the motorhome within its departure angle. This could cause the exhaust pipe to become damaged or sheared off if the vehicle is driven on an incline.

If the generator exhaust pipe is damaged or sheared off, it may cause carbon monoxide to intrude inside the vehicle, which could result in illness or death.

 

WHAT SHOULD YOU DO?

Please make certain your motorhome is immediately inspected and repaired by contacting an authorized REV Recreation Group Inc. dealer.

For assistance locating an authorized REV Recreation Group servicing dealer, please call REV Recreation Group Owner Relations toll-free at:

(800) 322-8216

 

WHAT WILL REV RECREATION GROUP DO?

With your continued satisfaction in mind, it is our intention to have these repairs made at your convenience with as little disruption as possible. Effective immediately, REV RV dealers have been supplied with all of the information needed to enable them to inspect, and if necessary, replace the generator exhaust pipe and properly route it.

The repair should take less than one hour to complete; however, because of service scheduling times, your dealer may need the vehicle for a longer period of time. This service will be performed for you free of charge.

When you deliver your motorhome for repairs, your dealer will complete a Repair Order. Upon completion of the repair, please sign the Repair Order and fi ll out the enclosed selfaddressed Vehicle/Owner Information Update Card and return it to REV Recreation Group.

If you have changed your address or sold the motorhome, please take a moment to provide the name and address of the person or dealership you sold it to on the enclosed Vehicle/Owner Information Update Card and return it to REV Recreation Group. This will allow us to update our records and if necessary, notify the new owner using the information you provide.

Alternately, you may use a smart device and the QR code at right to navigate to the online owner update form, or visit: https://www.fl eetwoodrv.com/for-owners/support/change-of-ownership

If you have paid to have this concern corrected previously, you may be eligible for reimbursement of your cost for that repair. For more information, please contact REV Recreation Group Owner Relations at (800) 322-8216.

For more information regarding this recall, contact:

REV RECREATION GROUP OWNER RELATIONS – RECALL #191125REV
P.O. Box 1007
Decatur, Indiana 46733
(800) 322-8216

 

If you are unable to obtain the specifi ed repair promptly and without charge, please contact REV Recreation Group Owner Relations using the above information.

If you believe that the dealer and REV Recreation Group Inc. have failed or have been unable to remedy the defect without charge or within a reasonable period of time, you may submit a complaint to:

Administrator
National Highway Traffic Safety Administration
1200 New Jersey Avenue, S.E.
Washington, DC 20590

Or call the toll-free Vehicle Safety Hotline at 1-888-327-4236
(TTY: 1-800-424-9153)
or go to https://www.safercar.gov

 

REV Recreation Group Inc. is taking these steps in the interest of your safety. We regret any inconvenience this may cause you.

Sincerely,

 

REV RECREATION GROUP INC.

 


IMPORTANT SAFETY RECALL

RECALL 191125REV
NHTSA # 19V860
January 2020
THIS NOTICE APPLIES TO YOUR VEHICLE

 

VIN:                                                                    

Model Year «YEAR» «MAKE» «PRODUCT»  «MODEL» REV RV Unit Serial Number: «UIN»

Dear Valued Fleetwood Customer:

This notice is sent to you in accordance with the requirements of the National Traffic and Motor Vehicle Safety Act.

REV Recreation Group Inc. has decided that a safety defect relating to motor vehicle safety exists in certain model year 2016-2020 Fleetwood brand Class A gas motorhomes:

 

Model year 2016-2020 Bounder – Manufactured March 20, 2015 – July 31, 2019

Model year 2018-2020 Southwind – Manufactured July 18, 2017 – July 24, 2019

 

WHAT IS THE PROBLEM?

On motorhomes affected by this recall, the generator exhaust pipe may be routed to exit the motorhome within its departure angle. This could cause the exhaust pipe to become damaged or sheared off if the vehicle is driven on an incline.

If the generator exhaust pipe is damaged or sheared off, it may cause carbon monoxide to intrude inside the vehicle, which could result in illness or death.

 

WHAT SHOULD YOU DO?  

Please make certain your motorhome is immediately inspected and repaired by contacting an authorized REV Recreation Group Inc. dealer.

For assistance locating an authorized REV Recreation Group servicing dealer, please call REV Recreation Group Owner Relations toll-free at:

(800) 322-8216

 

WHAT WILL REV RECREATION GROUP DO?

With your continued satisfaction in mind, it is our intention to have these repairs made at your convenience with as little disruption as possible. Effective immediately, REV RV dealers have been supplied with all of the information needed to enable them to inspect, and if necessary, replace the generator exhaust pipe and properly route it.

The repair should take less than one hour to complete; however, because of service scheduling times, your dealer may need the vehicle for a longer period of time. This service will be performed for you free of charge.

When you deliver your motorhome for repairs, your dealer will complete a Repair Order. Upon completion of the repair, please sign the Repair Order and fill out the enclosed self-addressed Vehicle/Owner Information Update Card and return it to REV Recreation Group.

If you have changed your address or sold the motorhome, please take a moment to provide the name and address of the person or dealership you sold it to on the enclosed Vehicle/Owner Information Update Card and return it to REV Recreation Group. This will allow us to update our records and if necessary, notify the new owner using the information you provide.

If you have paid to have this concern corrected previously, you may be eligible for reimbursement of your cost for that repair. For more information, please contact REV Recreation Group Owner Relations at (800) 322-8216.

 

For more information regarding this recall, contact:

REV RECREATION GROUP OWNER RELATIONS – RECALL #191125REV
P.O. Box 1007
Decatur, Indiana 46733
(800) 322-8216

If you are unable to obtain the specified repair promptly and without charge, please contact REV Recreation Group Owner Relations using the above information.

If you believe that the dealer and REV Recreation Group Inc. have failed or have been unable to remedy the defect without charge or within a reasonable period of time, you may submit a complaint to:

Administrator
National Highway Traffic Safety Administration 1200
New Jersey Avenue, S.E.
Washington, DC 20590

Or call the toll-free Vehicle Safety Hotline at 1-888-327-4236
(TTY: 1-800-424-9153)
or go to https://www.safercar.gov

 

REV Recreation Group Inc. is taking these steps in the interest of your safety. We regret any inconvenience this may cause you.

Sincerely,

 

REV RECREATION GROUP INC.

 


IMPORTANT RECALL INFORMATION #191125REV

January 2020

TO:ALL REV RECREATION GROUP DEALER PRINCIPALS, SERVICE MANAGERS  AND PARTS MANAGERS
SUBJECT:RECALL CAMPAIGN #191125REV
Generator Exhaust Pipe Routing

 

 

REV Recreation Group, Inc., on behalf of its manufacturing center located in Decatur, Indiana, is requesting your assistance in conducting a voluntary recall notification campaign in accordance with the United States National Traffic and Motor Vehicle Safety Act and the Canada Motor Vehicle Safety Act.

 

REV Recreation Group, Inc. has decided that a safety defect relating to motor vehicle safety exists in certain model year 2016-2020 Fleetwood and Holiday RamblereBay logo brand Class A gas motorhomes:

Model yearProductManufacturing date range
2016-2020Fleetwood Bounder3/20/2015 – 7/31/2019
2018-2020Fleetwood Southwind7/18/2017 – 7/24/2019
2016-2020Holiday RamblereBay logo Vacationer7/13/2015 – 7/24/2019

 

We are notifying the owners of the affected units in order to correct the problem. Copies of the letters sent to owners of record are attached for your information.

 

WHAT IS THE PROBLEM?

On motorhomes affected by this recall, the generator exhaust pipe may be routed to exit the motorhome within its departure angle. This could cause the exhaust pipe to become damaged or sheared off if the vehicle is driven on an incline.

If the generator exhaust pipe is damaged or sheared off, it may cause carbon monoxide to intrude inside the vehicle, which could result in illness or death.

 

WHAT SHOULD YOU DO?

Owners of the above mentioned motorhomes have been asked to contact an authorized REV Recreation Group dealer to have the described defect remedied. In the event that you are contacted by a customer, please verify eligibility by referring to the serial number range listed in the attached Recall Service Bulletin #191125REV prior to beginning repairs.

 

Once repairs have been completed according to Recall Service Bulletin #191125REV, have the customer sign your dealership’s Internal Repair Order. Warranty labor claims are to be submitted electronically to REV Recreation Group. Customers will not be charged for these repairs.

If you have one of these vehicles in your inventory, you will be mailed a Safety Recall Notice for that specific motorhome. REV Recreation Group dealers are required to make repairs to stock units on dealer lots prior to sale or lease.

 

Federal Law (Section 154 of the National Highway Traffic and Motor Vehicle Safety Act) of 1966 requires that:  If you have received a notice of recall or failure to comply from REV Recreation Group, Inc. or any component manufacturer, you must repair or otherwise correct the defect on vehicles remaining in your inventory according to the notification before selling or leasing the vehicles.  Any vehicle lessor receiving this recall notice must forward a copy of the notice to the lessee within ten days.

 

Please carefully review this entire package with your parts and service staff to familiarize them with the step-by-step procedure and implement the Voluntary Recall Campaign.

Thank you for helping REV Recreation Group with its continuing efforts to maintain customer satisfaction. If you have any questions, please contact your REV Recreation Group Service Center.

 

Sincerely,

 

REV RECREATION GROUP, INC.

 

Attachments:

Recall #191125REV US Customer Letter
Recall #191125REV Canadian Customer Letters
Recall #191125REV Service Bulletin

 

 

 

Dealer Notification Letter
NHTSA Recall # 19V860

Recall Campaign #191125REV
Transport Canada Recall # 2019-636

 


13 Affected Products

Vehicles

MAKEMODELYEAR
FLEETWOODBOUNDER2016-2020
FLEETWOODSOUTHWIND2018-2020
HOLIDAY RAMBLEReBay logoVACATIONER2016-2020

 


11 Associated Document

Recall Quarterly Report #1, 2020-1

RCLQRT-19V860-2034.PDF 211.14KB

 


ISSUED Owner Notification Letter(Part 577)

RCONL-19V860-8982.pdf 106.055KB

 


ISSUED Owner Notification Letter(Part 577)

RCONL-19V860-0561.pdf 112.588KB

 


Remedy Instructions and TSB

RCRIT-19V860-9544.pdf 2239.154KB

 


Manufacturer Notices(to Dealers,etc)

RCMN-19V860-0183.pdf 112.362KB

 


ISSUED Renotification Notice

RCRN-19V860-8924.pdf 225.605KB

 


ISSUED Renotification Notice

RCRN-19V860-1165.pdf 232.902KB

 


Defect Notice 573 Report

RCLRPT-19V860-4114.PDF 221.677KB

 


Recall Acknowledgement

RCAK-19V860-7539.pdf 244.802KB

 


Recall Quarterly Report #2, 2020-2

RCLQRT-19V860-7698.PDF 211.24KB

 


Recall Quarterly Report #3, 2020-3

RCLQRT-19V860-3134.PDF 211.331KB

 


Latest Recalls Documents

https://www-odi.nhtsa.dot.gov/acms/cs/documentList.xhtml?docId=19V860&docType=RCL

 


 

SaleBestseller No. 1
Oxseryn 4400-Watts Inverter Generator, Open Frame Generator Gas Powered, Emergency Home Backup, RV Ready 30A Outlet, EPA Compliment
  • Powerful Output: 4400 peak watts and 3400 running watts, 2*120V AC ports, 1* 30A RV port, 1*12V DC port, 14 hours runtime at 25% load
  • Gas Powered: 2 gallon fuel tank capital
  • Features: Inverter technolog, ECO mode, EPA compliment, RV ready, overload protection, low oil shutdown, cold start technology
  • Portable Generator: Weight 56lbs, lightweight and easy to move
  • Note: All Oxseryn generators are functionally tested in the factory, so there may be a slight smell of gas when you receive it
Bestseller No. 2
Westinghouse 12500 Watt Dual Fuel Home Backup Portable Generator, Remote Electric Start, Transfer Switch Ready, Gas and Propane Powered
  • 9500 Running Watts and 12500 Peak Watts (Gasoline); 8500 Running Watts, 11200 Peak Watts (Propane); Remote Start with Included Key Fob, Electric and Recoil Start; Up to 12 Hours of Run Time on a 6. 6 Gallon Fuel Tank with Fuel Gauge
  • Features Two GFCI 120V 5–20R 20A Standard Household Receptacle, One Transfer Switch Ready 120V L14-30R 30A, and One RV Ready 120/240V 14–50R 50A; All Outlets Have Rubber Covers for Added Safety
  • Powered by a Heavy Duty 457cc Westinghouse 4-Stroke OHV Engine Featuring a Long-Lasting Cast Iron Sleeve with Automatic Low Oil Shutdown and Digital Hour Meter. VFT display gives you real time updates with the voltage output, frequency, and lifetime hours
  • Plug-and-Play: Comes with a Remote Start Key Fob, 12V Battery Charger, Oil, an Oil Funnel, a Tool Kit, and a User’s Manual to Get You Started Right Out of the Box (Minimal Assembly Required)
  • All Westinghouse Portable Generators are Functionally Tested in the Factory and May Contain Minimum Residual Oil and/or Fuel Odor; EPA Compliant; Backed By 3-Year Limited Service, Labor, and Parts Coverage and Nationwide Customer Service Network
Bestseller No. 3
MARBERO Portable Power Station 88Wh Camping Lithium Battery Solar Generator Fast Charging with AC Outlet 120W Peak Power Bank(Solar Panel Optional) for Home Backup Outdoor Emergency RV Van Hunting
  • EFFICIENT CHARGING: Use the adapter included in the package to charge the power station from 0 to 80% in 2hrs, and use the this power supply to charge other devices at the same time while charging, which could be equivalent to a charging strip , improving the efficiency of uses. It can be charged efficiently with MARBERO's dedicated 30W or 60W solar panel, suitable for outdoor or backyard camping
  • COMPACT & PORTABLE DESIGN: Super slim size(6.5 x 4.6 x 3.1 inches), the portable power station is about the size of a basic DSLR; With the strong yet lightweight(3.2lbs) plastic case, plus an ergonomic handle, it's quite suitable for outdoor camping, road trips, backyard camping, home, school, office,etc.
  • MULTI-OUTPUT: There are 8 output ports could be used at the same time, and the built-in BMS system ensures stability and safety. The car DC charger output cable(included) will supply power to car refrigerators, vacuum cleaners, and air compressor in emergencies. USB and USB C PD ports are compatible for all the mobile phones(1hr full), tablets(1.5hrs full), laptops(2hrs full), it's an essential unit for road trips. The two AC output ports will power home appliances, such as small TVs, game consoles, projectors, inflatable beds, drones, etc.
  • BRIGHT LED LIGHTS: With three levels of brightness, the portable power bank can be used as a large-capacity professional flashlight when needed, which is very suitable for use when the car breaks down, power outage at home, or a tent power supply. The 1st level can be used for 68hrs(light up a small room), the 2nd level can be used for 48hrs(lighting for walking at night), and the 3rd level can be used for 37hrs(light up the living room). In case of emergency, there is SOS flashing mode, use the internationaleBay logo SOS frequency to call for help.
  • SECURED & ASSURED: The Battery Management System (BMS) allows for voltage control, temperature control and more advanced safety operations. Designed with the cooling vents on the back to help this portable power supply keep the temperature constant, its internal electrical elements will not be damaged by high temperatures. When it comes to short circuit or overload, it automatically shuts off the power to protect itself and the powered devices. By using the cylindrical batteries which meets UL safety standards. UL drop tested (3 drops from 0.9m on any kind of surface).
SaleBestseller No. 4
Oxseryn Power Equipment 4400 Watts Inverter Generator Gas Powered, Portable Open Frame Generator, Low Noise with ECO Mode, RV Ready, Emergency Home Backup
  • 𝗣𝗼𝘄𝗲𝗿𝗳𝘂𝗹 𝗢𝘂𝘁𝗽𝘂𝘁 - 4400 peak watts and 3400 running watts, perfect for RV camping and home backup
  • 𝗠𝘂𝗹𝘁𝗶-𝗢𝘂𝘁𝗽𝘂𝘁 𝗢𝗽𝘁𝗶𝗼𝗻𝘀 - Includes 2*120V AC ports, 1*12V DC port, 1*RV port
  • 𝗟𝗼𝗻𝗴 𝗥𝘂𝗻𝘁𝗶𝗺𝗲: Runs for up to 14 hours at 25% load with ECO mode, 2 gallon fuel tank with fuel gauge, allows you to check fuel levels at a glance, keeping you prepared
  • 𝐋𝐨𝐰 𝐍𝐨𝐢𝐬𝐞: Under 72 dBA from 23FT away, this generator provides steady power for your home during a power outage or RV nights
  • 𝗟𝗶𝗴𝗵𝘁𝘄𝗲𝗶𝗴𝗵𝘁 𝗮𝗻𝗱 𝗣𝗼𝗿𝘁𝗮𝗯𝗹𝗲: Only 56lbs, easy to move around
SaleBestseller No. 5
generator" title="ERAYAK 4500W Portable Inverter Generator for Home Use, Super Quiet Small Generator for Camping Outdoor Emergency Power Backup, Gas Powered Engine, ECO Mode, EPA Compliant" rel="nofollow noopener sponsored" target="_blank"> ERAYAK 4500W Portable Inverter Generator for Home Use, Super Quiet Small Generator for Camping Outdoor Emergency Power Backup, Gas Powered Engine, ECO Mode, EPA Compliant
ERAYAK 4500W Portable Inverter Generator for Home Use, Super Quiet Small Generator for Camping Outdoor Emergency Power Backup, Gas Powered Engine, ECO Mode, EPA Compliant
  • Powerful & Clean Energy Output:4500W peak watts / 3500W running watts, delivering dependable power for RVs, camping, home backup, and outdoor work. Advanced inverter technology provides clean and stable electricity, making it safe for sensitive electronics like laptops, CPAP machines, and mobile devices.
  • Quiet Generator: Ultra-quiet operation at just 60.5 dB(A)—perfect for campgrounds, RV parks, and residential areas. Eco Mode dynamically adjusts engine speed to optimize fuel efficiency and reduce noise.
  • Compact, Lightweight & RV Generator: Portable inverter generator 4500P weighs just 55.12 lbs for easy transport and storage. Compact dimensions: 20" (L) x 12.2" (W) x 19.3" (H). Compatible with Erayak wheel kit & telescoping handle for enhanced mobility.
  • 50A Parallel-ready: Connect two units to double your power output (parallel kit sold separately). When two 4500P units are connected in parallel, they deliver a rated power of 7,000W and a peak power of 9,000W, while supporting a 50A output.
  • Versatile Power Outlets for Every Need: 1 x 30A L5-30R (TT-30R) outlet for RV power connectivity.2 x 120V AC outlets for home appliances, tools, and lights.12V 5A cigarette lighter port + USB-A & USB-C ports for charging multiple devices on the go.Advanced safety with built-in 20A & 30A circuit breakers for overload protection.

Last update on 2026-05-23 / Affiliate links / Images from Amazon Product Advertising API


 

This product presentation was made with AAWP plugin.

Leave a Comment

Share to...