March 16, 2021 NHTSA CAMPAIGN NUMBER: 21V180000
Incorrectly Routed Furnace Hose May Cause Gas Leak
A gas leak in the presence of an ignition source can increase the risk of fire or explosion.
NHTSA Campaign Number: 21V180
Manufacturer Jayco
, Inc.
Components EQUIPMENT
Potential Number of Units Affected 29
Summary
Jayco
, Inc. (Jayco
) is recalling certain 2021 Jayco
Embark, and Entegra Reatta Class A Motorhomes. The LP furnace hose may be routed incorrectly, which could restrict the gas flow, or cause chafing against surrounding components, resulting in a gas leak.
Remedy
Jayco
will notify owners, and dealers will remove the existing LP line, and install a new extended gas manifold, free of charge. The recall began March 29, 2021. Owners may contact Jayco
customer service at 1-800-517-9137. Jayco
’s number for this recall is 9903565.
Notes
Owners may also contact the National Highway Traffic Safety Administration Vehicle Safety Hotline at 1-888-327-4236 (TTY 1-800-424-9153), or go to www.safercar.gov.
INCORRECT ROUTING OF LP HOSE TO FURNACE
| Bulletin Type: | Safety Recall | Publication Date: | March 29, 2021 | |
| Bulletin #(s): | 21V-180 | Make(s): | Entegra Jayco | |
| Job Code(s): | 9903565 | Model(s): | Reatta Embark | |
| Flat Rate(s): | .75 hour | Model Year(s): | 2021 |
| Incident: | Incorrect routing of the LP hose to furnace may cause damage from surrounding components and/or restrict gas flow. |
| Affected Units: | 2021 Reatta : M1NJ 8061 8062 5063
2021 Embark: M1NJ 4051 4054 4056 |
| Parts Kit: | Parts Kit #: 21V-180 |
| Parts Kit Contents:
1 Gas line hose (furnace) 1 Gas manifold extension | |
| Misc. Tools & Supplies: | Screw gun w/square and Phillips bit
Putty knife 9/16” open end wrench 3/4” open end wrench Spray Foam insulation Electrical tape Butyl tape Wago connectors |
INSTRUCTIONS
- The gas line manifold access is located in the rear driver’s side storage compartment. Using a screw gun with a Phillips bit, remove the back access panel as shown to the right. Set screws aside for reuse.
- Locate the LP manifold in the storage compartment. Using a 9/16” open-end wrench, remove the (furnace) LP hose on the bottom of the manifold as shown to the right.
- Follow the LP hose to the back of the compartment. Loosen the hose from the foam sealant and remove any of it that will prevent the hose from being fed through the compartment wall.
- Push the hose through the compartment hole as far as possible. You will be removing this hose.
- Remove the furnace cover. You will need to remove the exhaust (#1) prior to removing the cover (#2). Set all parts and screws aside for reuse later.
- Inside the unit, locate the water heater in the rear bath cabinet.
NOTE: Open the bath faucet and drain all water prior to disconnecting the water line hook-ups(s)
- Disconnect both water lines. You should be able to loosen and disconnect them by hand (#4 & 5).
- Using a wire cutter, cut the wires connected to the water heater, taking note of the connections as you will need to reconnect them later in the process (#6).
- Using a 3/4” open-end wrench, disconnect the gas line from the water heater (#7).
- On the exterior of the unit, using a screw gun with a square head bit, remove the water heater door by removing the (2) hinge screws from the unit. The screws attaching the hinge to the door should remain attached. Set the screws aside for later reuse (#8).
NOTE: Have a second person hold the door while you remove it from the unit to help prevent damage to the door or unit.
- Remove all of the screws that secure the water heater to the unit. Set the screws aside for reuse (#9).
NOTE: Having a second person assist in removing the water heater from the unit will help prevent damage to the water heater and the sidewall of the unit.
- Remove the water heater from the unit. You may have to gently pry under the edge of the water heater with a putty knife to break the butyl tape seal (#10).
- Removing the water heater will give you better access to the furnace LP hose. Push the hose through the hole far as possible to help in removing the hose. You will need to go under the unit to remove the hose. Go under unit directly under the furnace, locate the furnace LP hose and remove it from the unit.
- Install the new furnace LP hose. Starting in the storage compartment, put the new LP hose through the hole in the compartment back wall (where you removed the old hose). You may have to remove additional foam sealant.
- Push the LP hose through allowing enough LP hose in the compartment to reconnect to the manifold.
- Apply pipe sealant to the threads on the LP hose. Using a 9/16” open-end wrench, connect the LP hose to the manifold.
- Going back under the unit directly under the furnace, insert the other end of the LP hose through the hole the original LP was in. Push as much hose as possible up into the unit.
- Install the new gas manifold extension from the inside of the u The extension should be installed with end (A) in the back of the furnace and end (B) downward at the furnace connection (#12).
- Install the extension support bracket on the water heater shelf support cleat (#13)
- Pull the new LP hose into the cabinet far enough to be easily installed on the extension. Make sure the LP hose is not twisted, kinked or pinched.
- Install the hose to the extension. Make sure the connection is tight.
Using a 3/4” open-end wrench, install the furnace connection to the manifold extension connection (#14).
- Re-install the water heater in the unit (#16).
NOTE: Having a second person assist in installing the water heater from the unit will help prevent damage to the water heater and the sidewall of the unit.
- Re-install the (water heater) screws (#17)
Re-connect the water lines making sure they are tight (#4 & 5).
- Re-connect the (water heater) LP gas hose (#7).
- Strip the wires that were previously cut back approximately 5/16” (#6). Using Wago connectors, reconnect the water heater wires. Wrap the connectors with electrical tape as shown below.
- Add foam sealant (in the storage compartment) around the newly installed LP hose replacing any foam that was taken out when removing the original hose (#18).
- Re-install the (back) compartment access panel.
- Re-install the water heater door.
NOTE: Having a second person hold the door while you re-install it will help prevent damage to the door or unit.
| Jayco |
| 903 South Main Street • P.O. Box 460 • Middlebury, IN 46540 |
Safety Recall: 21V-180
March 29, 2021
IMPORTANT SAFETY RECALL
This Notice Applies to Your Recreational Vehicle «unit_serial_»
Dear Valued Customer:
This notice is sent to you in accordance with the National Traffic and Motor Vehicle Safety Act.
Jayco
has decided that a defect, which relates to motor vehicle safety, exits in certain 2021 Embark and Reatta motorhomes.
Reason for this recall
Incorrect routing of the LP hose to the furnace, creates risk of damage from surrounding components and may restrict the gas flow. A damaged LP hose could leak, causing gas build up in the motorhome and if there is an ignition source present, creates risk of explosion and fire.
Recall Remedy
Remove and replace the LP hose to the furnace, routing LP hose correctly to ensure a safe and secure location. The remedy is free of charge and will take approximately .75hour to complete.
What we need you to do
Please contact a Jayco
or Entegra Dealer and set an appointment for this remedy.
Federal regulations require that any vehicle lessor receiving this recall notice must forward a copy of this notice to the lessee within ten days.
If you had this repair completed prior to receipt of this recall notice, you may be eligible to receive reimbursement for the cost of obtaining a pre-notification remedy of the problem associated with this recall.
If you take your recreational vehicle to your dealer on the agreed service date and the dealer does not remedy this condition on that date or within three (3) days, please contact our Customer Service Department at 800-517-9137. If you are unable to get this safety defect remedied without charge and/or within a reasonable amount of time after contacting your dealer and Jayco
customer service, you may want to contact NHTSA. To submit a written complaint, contact the Administrator, National Highway Traffic Safety Administration, 1200 New Jersey Avenue, SE., Washington, DC 20590; or call the toll-free Vehicle Safety Hotline at 1-888-327-4236 (TTY: 1-800-424-9153): or go to https://www.safercar.gov.
We certainly regret this inconvenience; however, your safety is our most important priority.
Sincerely,
Compliance Management
Jayco
Motorized Products
SEOCONTENT-START
IMPORTANT SAFETY RECALL
Dear Valued Dealer:
This notice is sent to you in accordance with the National Traffic and Motor Vehicle Safety Act.
Jayco
has decided that a defect, which relates to motor vehicle safety, exits in certain 2021 Embark and Reatta motorhomes.
Incorrect routing of the LP hose to the furnace, creates risk of damage to the LP hose from surrounding components and may restrict the gas flow. A damaged LP hose could leak, causing gas build up in the motorhome and if there is an ignition source present, creates risk of explosion and fire.
Remove and replace the LP hose to the furnace, routing LP hose correctly to ensure a safe and secure location. All pertinent information regarding this recall is available under the Applications > Recalls section of the website.
Our records show the following unit is affected by this recall, and is part of the current inventory at your Dealership.
VIN
Before placing an order for the Recall Parts Kit, please confirm the unit serial number requires the Recall Remedy, using CASE RECALL LINES in Jayco
Partners. The Instructions for the Recall Remedy are available under the Case Recall 21V-180 attachments.
Federal law requires the Recall Remedy completed on this unit prior to customer delivery.
If you sold this unit recently, please contact the owner immediately to inform them of this recall. In addition, please register this unit by submitting the Warranty Registration information. Federal regulations require that any vehicle lessor receiving this recall notice must forward a copy of this notice to the lessee within ten days.
We certainly regret this inconvenience; however, our Customers’ safety is our most important priority.
Sincerely,
Compliance Management
Jayco
Motorized Product
Safety Recall: 21V-180
March 29, 2021
Reason for Recall r this recall
What we need you to do
Recall Remedy r this recall
SEOCONTENT-END
2 Affected Products
Vehicles
| MAKE | MODEL | YEAR |
| ENTEGRA | REATTA | 2021 |
| JAYCO | EMBARK | 2021 |
10 Associated Documents
Manufacturer Notices(to Dealers,etc)
RCMN-21V180-9651.pdf 137.787KB
ISSUED Owner Notification Letter(Part 577)
RCONL-21V180-0147.pdf 55.866KB
Remedy Instructions and TSB
RCRIT-21V180-9166.pdf 948.286KB
Recall Quarterly Report #2, 2021-2
RCLQRT-21V180-8050.PDF 211.228KB
Recall 573 Report – Amendment 1
RCLRPT-21V180-8371.PDF 213.326KB
Recall Acknowledgement
RCAK-21V180-2282.pdf 690.244KB
Defect Notice 573 Report
RCLRPT-21V180-3778.PDF 213.108KB
Recall Quarterly Report #1, 2021-1
RCLQRT-21V180-1998.PDF 211.133KB
Recall Quarterly Report #4, 2021-4
RCLQRT-21V180-3991.PDF 211.422KB
Recall Quarterly Report #3, 2021-3
RCLQRT-21V180-4302.PDF 211.309KB
Latest Recalls Documents
- COST-EFFECTIVE REPLACEMENT: The RP-35Q 35,000 BTU/h Replacement RV Furnace Core by Suburban offers a simple and affordable alternative to replacing your furnace. Save time and money with this replacement module that slides into your existing cabinet, providing all the benefits of a new furnace without the extensive installation process.
- DIRECT REPLACEMENT FOR SUBURBAN SERIES: Specifically designed to replace the Suburban SF-35, SF-35Q, SF-42, SF-42Q, and SF-Q, this replacement module ensures compatibility and seamless integration with your existing furnace setup.
- COMPACT AND EFFICIENT DESIGN: Measuring 20 x 17 x 7.5 inches, the RP-35Q furnace core replacement offers a compact solution that maximizes space efficiency. It fits snugly into your RV's furnace cabinet, optimizing your interior layout.
- AFFORDABLE AND WARRANTY-BACKED: This furnace core replacement is an affordable alternative to replacing old and worn-out furnace parts with little to no warranty. Enjoy peace of mind with a two-year limited warranty, ensuring quality and reliability.
- TIME-SAVING INSTALLATION: Installing the RP-35Q Replacement Furnace Core is straightforward and time-saving. Simply slide the module into your existing furnace cabinet, avoiding the complexities and costs associated with a full furnace replacement.
- High-Capacity RV Heater: This 35,000 BTU RV heater delivers superior warmth, perfect for larger motorhomes and travel trailers in freezing climates
- Precision Thermostat Control: Equipped with a thermostat for RV furnace, this unit allows you to accurately set and maintain the perfect temperature inside your vehicle
- Powerful Forced Air System: As a forced air furnace for RV, it ensures rapid and even distribution of heat throughout the entire living space of your camper
or trailer - Corrosion-Resistant Build: This heating unit for RV is constructed with materials that resist corrosion, enhancing its durability and lifespan
- Professional-Grade Solution: Ideal for upgrading your RV's furnace or heater, this system provides dependable, high-output performance for extended trips and full-time living
- Simple Installation & Easy Replacement: This RV furnace replacement core (17" W × 7.1" H × 20" D) is engineered to fit other brands’ SF-FQ and SF-Q series models. Designed for straightforward installation, it provides a cost-effective way to restore heating performance and extend the service life of aging RV furnace parts without structural modifications.
- 35,000 BTU Powerful RV Furnace: Features a 35,000 BTU high-output burner with strong 320 CFM airflow, delivering fast and even heating throughout the cabin. Reaches a maximum output temperature of up to 104°F for reliable cold-weather performance, ideal for large RVs including travel trailers and campers
, typically measuring 28–38 ft in length. - Quiet 40 dB Operation for Comfort: Designed with user comfort in mind, the furnace operates quietly at only 40dB, minimizing noise disruption so you can relax, sleep, or enjoy conversations in a serene RV interior.
- Smart Control Thermostat: Unlike basic RV gas furnace, ours offers 3 modes (quick heat/standard/sleep) and fault monitor alerts for easy troubleshooting. Set your ideal temperature and choose from 4 power levels (17K / 25K/ 30K / 35K BTU) to get fast, efficient, and customized RV heating.
- Multiple Safety Protections for Reliable Operation: The RV heater integrated anti-explosion ignition procedure, flame-out protection, gas pressure regulator valve, and an intelligent wind pressure sensor. Continuous electronic monitoring helps ensure safe, stable, and dependable heating performance.
- COST-EFFECTIVE REPLACEMENT: The RP-30FQ 30,000 BTU/h Replacement RV Furnace Core by Suburban offers a simple and affordable alternative to replacing your furnace. Save time and money with this replacement module that slides into your existing cabinet, providing all the benefits of a new furnace without the extensive installation process.
- DIRECT REPLACEMENT FOR SUBURBAN SERIES: Specifically designed to replace the Suburban SF-25F, SF-25FQ, SF-30F, SF-30FQ, SF-FQ Furnace Core, this replacement module ensures compatibility and seamless integration with your existing furnace setup.
- COMPACT AND EFFICIENT DESIGN: Measuring 20 x 17 x 7.5 inches, the RP-30FQ furnace core replacement offers a compact solution that maximizes space efficiency. It fits snugly into your RV's furnace cabinet, optimizing your interior layout.
- AFFORDABLE AND WARRANTY-BACKED: This furnace core replacement is an affordable alternative to replacing old and worn-out furnace parts with little to no warranty. Enjoy peace of mind with a two-year limited warranty, ensuring quality and reliability.
- TIME-SAVING INSTALLATION: Installing the RP-30FQ Replacement Furnace Core is straightforward and time-saving. Simply slide the module into your existing furnace cabinet, avoiding the complexities and costs associated with a full furnace replacement.
- Rapid Heating: Powerful 35,000 BTU max output (4 Power Leverls, adjustable down to 17,000 BTU) delivers 320CFM airflow for rapid heating in campers
, motorhomes, and trailers. - Whisper-Quiet Sleep Mode: FOGATTI RV Furnace operates at just 40dB in sleep mode—quieter than a library, ensuring undisturbed rest for deep sleep on the road.
- Smart Control: Unlike basic rv gas furnace, ours offers 3 modes (quick heat/standard/sleep) and fault monitor alerts for easy troubleshooting.
- Space-saving: Compatible with most RV furnace brands for simple replacement. Dimensions: 8"H x 17-3/4"W x 20.1"D, this RV furnace replacement delivers powerful heating in tight spaces, featuring versatile horizontal/vertical mounting.
- High-Efficiency Heat Exchange: Upgraded heat exchanger maximizes gas efficiency, extending travel range. Outputs up to 104°F for reliable performance even in sub-zero.
Last update on 2026-05-27 / Affiliate links / Images from Amazon Product Advertising API
This product presentation was made with AAWP plugin.