June 4, 2021 NHTSA CAMPAIGN NUMBER: 21V428000
Propane Regulator May Fail and Cause Fire
Increased propane pressure can enlarge the flames in gas appliances, increasing the risk of a fire.
NHTSA Campaign Number: 21V428
Manufacturer Heartland
Recreational Vehicles, LLC
Components EQUIPMENT
Potential Number of Units Affected 22,326
Summary
Heartland
Recreational Vehicles, LLC. (Heartland
) is recalling certain 2018-2021 Mallard, Shadow Cruiser, Sundance XLTTT, Wilderness, Prowler, Trail Runner, 2018-2019 Pioneer, Terry Classic, 2020-2021 Lithium, and 2021 North Trail trailers equipped with a Winntec model 6020 two-stage propane regulator. The regulator may fail, causing an increase in propane pressure.
Remedy
Dealers will replace the regulator and test the propane system for leaks, free of charge. Owner notification letters were mailed August 3, 2021. Owners may contact Heartland
customer service at 1-877-262-8032.
Notes
Owners may also contact the National Highway Traffic Safety Administration Vehicle Safety Hotline at 1-888-327-4236 (TTY 1-800-424-9153), or go to www.nhtsa.gov.
21v428 Winntec Regulator Inspection/Replacement
T.C. 2021-364
- Locate LP tanks at front of unit and remove cover to access regulator.
- Locate date stamp on left front of regulator. If stamped N 20 xx this will be inspect only and picture will need to be provided of date stamp. If stamped N 17 xx, N 18 xx or N 19 xx the regulator will need to be replaced.
- To replace regulator, make sure LP bottles are turned off by turning knobs clockwise and disconnect pig tail from LP bottles.
- Remove regulator from threaded rod.
3/4” wrench
7/8” wrench
- Once regulator is removed, using a ¾” wrench remove the brass fitting at the bottom of the old regulator that the LP line connects to and install on the new regulator with new pipe compound or thread tape. DO NOT USE PIPE COMPOUND OR THREAD TAPE ON FLARED FITTINGS
- Reinstall regulator on threaded rod and reconnect pig tails.
- Once replacement is complete a drop pressure test will need performed.
- REGULATOR MUST BE RETURNED!! PLEASE USE BOX THAT NEW REGULATOR WAS SHIPPED IN.
Tools and material need for repair:
3/4” wrench
7/8” wrench
Pipe compound or Thread tape
Inspection of the Winntec Model #6020 LP Regulator
1. Locate LP tanks at front of unit and remove cover to access regulator.
2. Locate the LP regulator between the LP Tanks. Only the Winntec Model #6020 – Dual Stage Double Cylinder – Automatic Changeover Regulator is affected.
3. Locate the manufacturing date code stamp on left front of regulator.
4. If the manufacturing date code stamped into the regulator is N 17 XX, inspect the propane system to insure there are no visual or functional issues. If the manufacturing date code stamped into the regulator is N18 XX, N 19 XX or N 20 XX replace the regulator per the instructions below.
5. To replace regulator, make sure LP bottles are turned off by turning knobs clockwise and disconnect pig tail from LP bottles.
6. Remove regulator from threaded rod.
7. Remove the pigtails from the regulator.
8. Remove regulator from the Main LP line.
9. Once regulator is removed, using a 3/4’” wrench remove the brass fitting at the bottom of the old regulator that the LP line connects to and install on the new regulator with new pipe compound or thread tape. DO NOT USE PIPE COMPOUND OR THREAD TAPE ON FLARED FITTINGS!
10. Reinstall regulator on threaded rod and reconnect pig tails.
11. Once replacement is complete a drop pressure test will need performed.
12. Proceed with a Drop Pressure Test:
a. Insert manometer into LP system.
b. Turn on both LP tanks.
c. Turn off both LP tanks.
d. Bleed system down to 8” water column.
e. System must hold 8” water column for a minimum of 3 minutes.
13. Ensure system operating pressure is at 11” (+-0.5) water column with 50% load and lockout pressure does not exceed 14” water column.
11/4/20–Grand Design RV
informs THOR Ind. of three incidents involving Winntec Model 6020 regulators, where the regulators were suspected as the cause of fires. The Thor companies reviewed the issue internally and found no issues with these regulators at that time.
12/4/20–KZ RV informs THOR Ind. of two issues under investigation with the same suspect regulators.
12/22/20–Grand Design performs lab analysis on two failed regulators and finds they contain an oily substance inside. There is a belief that the oily substance is machining oil from a manufacturing process.
2/24/21–Grand Design informs THOR Ind. they are investigating several more fires, and will be sending regulators from those incidents for lab inspection.
3/16/21–Lab analysis performed on six regulators from Grand Design, including one exemplar and one from KZ RV. In the lab setting, the KZ RV regulator operated within allowable parameters, although it contained the same oily residue seen on the field samples.
4/19/21–THOR Ind. engages Exponent Engineering to conduct analysis of regulators to determine source of oily substance.
5/12/21–Exponent provides written report/presentation on regulator analysis.
5/14/21–Meeting held with Grand Design, Dehco, Winnspec International
, and Chen Fong to discuss regulator issue. Winnspec given until May 18, to return information regarding issues with their regulators.
5/21/21–THOR Ind. Discussed regulator issue with the Medium Heavy Duty ODI office.
5/24/21 & 5/25/21 – Meeting with Grand Design, Dehco, Winnspec International
, and Chen Fong at Livonia, MI testing facility, to discuss regulator investigation. Chen Fong agrees the regulator is allowing higher pressure than expected with a compromised second stage seal.
5/27/21–UFP determines that it supplied parts to Heartland
and disclosed this information to Thor Ind.
6/2/21 – Heartland
conducts safety committee meeting and decides to move forward with a recall for safety.
21E081 – Possible LP Regulator Failure – Winntec & WIC Model 6020 LP Regulators
http://oemdtc.com/7146/21e081-possible-lp-regulator-failure-winntec-wic-model-6020-lp-regulators
SEOCONTENT-START
IMPORTANT SAFETY RECALL
«OWNER»
«STREET»
«CITY», «STATE» «ZIP_CODE»
This notice applies to your vehicle: «WARRANTY ID»
Dear «OWNER»:
This notice is sent to you in accordance with the requirements of the National Traffic and Motor Vehicle Safety Act. Heartland
RV
(Heartland
) has decided that a defect which relates to motor vehicle safety on certain 2018-2021 Idaho Mallard, Idaho North Trail, Idaho
Shadow Cruiser, Idaho Sundance XLTTT, Idaho Wilderness, Prowler, Trail Runner, 2020-2021 Lithium, 2018-2019 Pioneer, & 2018-
2019 Terry Classic travel trailers. We apologize for any inconvenience this action may cause you, however your safety and continued
satisfaction are of the utmost importance to us.
The vehicles subject to this recall were built with a model 6020 propane regulator manufactured by Winntec
that may have a faulty secondary rubber seal. This malfunction may result in propane pressures that exceed
the propane appliances design limits and/or may be venting propane to the atmosphere which could result in
a fire that results in property damage, personal injury or death.
The remedy is to replace the regulator and pigtails. The repair should take approximately 35 minutes to
complete. This repair will be done at no cost to you.
At your earliest convenience, Please contact your local dealer to set up an appointment to have this
inspected and if needed corrected immediately, this service will be performed free of charge.
You will need the following information for the phone call:
VIN of your travel trailer
Name, Address, and Phone Number
If you have questions concerning this recall or if you need any assistance please contact the Warranty/Service Department by email
at ‘[email protected]’, or by phone at 877-262-8032. If you had appropriate repairs completed prior to receipt of this recall
notice, and if you incurred any direct cost in connection with obtaining such repair, you may be eligible to receive reimbursement from
Heartland
by contacting the Heartland
Warranty/Service Department.
If after contacting Heartland
Customer Service you are still not satisfied we have done our best to remedy this situation, you may also
submit a written complaint to: Administrator, National Highway Traffic Safety Administration, 1200 New Jersey Avenue, SE,
Washington, DC 20590. You may call the toll-free Vehicle Safety Hotline at 1-888-327-4236 (TTY: 1-800-424-9153; or go to
https://www.safercar.gov.) Federal regulations require that any vehicle lessor receiving this recall notice must forward a copy of this
notice to the lessee within ten days.
Thank you for your attention and cooperation in this matter.
Sincerely,
Heartland
RV Service Department
cc: National Highway Traffic Safety Administration (NHTSA)
Reason for
this recall
What we need
you to do
RECREATIONAL VEHICLE
SAFETY RECALL NOTICE
Safety Recall: 21v428
Date: August 1, 2018
What we
will do
**********************************************************************************************************
IMPORTANT SAFETY RECALL
«OWNER»
«STREET»
«CITY», «STATE» «ZIP_CODE»
Attn: Service Manager
Dear Heartland
RV Valued Dealer:
This notice is sent to you in accordance with the requirements of the National Traffic and Motor Vehicle Safety Act. Heartland
RV
(Heartland
) has decided that a defect which relates to motor vehicle safety exists in certain Heartland
travel trailers manufactured from
2018 to 2021. We apologize for any inconvenience this action may cause you, however your safety and continued satisfaction are of
the utmost importance to us.
On certain 2018-2021 Idaho Mallard, Idaho North Trail, Idaho Shadow Cruiser, Idaho Sundance XLTTT,
Idaho Wilderness, Prowler, Trail Runner, 2020-2021 Lithium, 2018-2019 Pioneer, & 2018-2019 Terry
Classic travel trailers were built with a model 6020 propane regulator manufactured by Winntec that may
have a faulty secondary rubber seal. This malfunction may result in propane pressures that exceed the propane
appliances design limits and/or may be venting propane to the atmosphere which could result in a fire that
results in property damage, personal injury, or death.
Instructions for the repair and a list of the affected coaches with their VIN #’s can be found on the warranty portal. Please verify your
stock for any of the affected coaches and if you have questions concerning this recall or if you need any assistance please contact the
Warranty/Service Department by email at ‘[email protected], or by phone at 877-262-8032.
Please have the VIN #’s of the affected travel trailers available when you call.
Federal regulations require that any vehicle lessor receiving this recall notice must forward a copy of this notice to the lessee within
ten days.
Note: It is a violation of federal law (CFR 49 Part 573.11&12) for a dealer to deliver a new vehicle that has been sold prior to
completing this recall. Please be sure to address any vehicles in your inventory that are affected by this recall action.
If you have questions concerning this recall or if you need any assistance please contact the Warranty/Service Department by phone
at 877-262-8032. If after contacting Heartland
Customer Service you are still not satisfied we have done our best to remedy this situation,
you may also submit a written complaint to Transport Canada – Road Safety, 80 rue Noël, Gatineau, Quebec J8Z 0A1 or call 1-800-
333-0510.
Thank you for your attention and cooperation in this matter.
Sincerely,
Heartland
RV Service Department
cc: National Highway Traffic Safety Administration (NHTSA)
Transport Canada
RECREATIONAL VEHICLE
SAFETY RECALL NOTICE
Safety Recall: 21v428
Transport Canada: 2021-364
Reason for
this recall
SEOCONTENT-END
31 Affected Products
Vehicles
| MAKE | MODEL | YEAR |
| CRUISER | SHADOW CRUISER | 2018-2021 |
| HEARTLAND | LITHIUM | 2020-2021 |
| HEARTLAND | MALLARD | 2018-2021 |
| HEARTLAND | NORTH TRAIL | 2021 |
| HEARTLAND | PIONEER | 2018-2019 |
| HEARTLAND | PROWLER | 2018-2021 |
| HEARTLAND | SUNDANCE | 2018-2021 |
| HEARTLAND | TERRY CLASSIC | 2018-2019 |
| HEARTLAND | TRAIL RUNNER | 2018-2021 |
| HEARTLAND | WILDERNESS | 2018-2021 |
13 Associated Documents
Recall 573 Report – Amendment 1
RCLRPT-21V428-5820.PDF 219.561KB
ISSUED Owner Notification Letter(Part 577)
RCONL-21V428-2744.pdf 135.745KB
Manufacturer Notices(to Dealers,etc)
RCMN-21V428-3357.pdf 116.001KB
Recall Acknowledgement
RCAK-21V428-5858.pdf 646.014KB
Defect Notice 573 Report
RCLRPT-21V428-4690.PDF 213.658KB
Miscellaneous Document – Chronology
RMISC-21V428-5492.pdf 50.889KB
Recall 573 Report – Amendment 2
RCLRPT-21V428-4758.PDF 219.631KB
Recall 573 Report – Amendment 3
RCLRPT-21V428-8406.PDF 219.7KB
Recall 573 Report – Amendment 4
RCLRPT-21V428-1275.PDF 219.717KB
Recall Quarterly Report #2, 2021-4
RCLQRT-21V428-1147.PDF 211.251KB
Remedy Instructions and TSB
RCRIT-21V428-7802.pdf 70.562KB
Remedy Instructions and TSB
RCRIT-21V428-9940.pdf 215.068KB
Recall Quarterly Report #1, 2021-3
RCLQRT-21V428-9403.PDF 211.132KB
Latest Recalls Documents
- Allows removal of the empty cylinder for refill without interrupting propane supply; includes 2 of the 12-inch pigtails to connect the regulator to the propane tank or propane supply
- For RVs with dual propane tanks; it automatically switches from primary to reserve tank when the primary tank is empty
- UL Listed Regulator, inlets are 1/4" SAE inverted flare and the outlet is 3/8" NPT female pipe thread; rated for 345,200 BTU
- Pairs well with our 48-inch thermoplastic hose; regulator is factory set at 11WC (water column)
- Double-stage design maintains constant gas pressure under changing demand and conditions
- Allows removal of the empty cylinder for refill without interrupting propane supply; includes 2 of the 12-inch pigtails to connect the regulator to the propane tank or propane supply
- For RVs with dual propane tanks; it automatically switches from primary to reserve tank when the primary tank is empty
- UL Listed Regulator, inlets are 1/4" SAE inverted flare and the outlet is 3/8" NPT female pipe thread; rated for 345,200 BTU
- Pairs well with our 48-inch thermoplastic hose; regulator is factory set at 11WC (water column)
- Double-stage design maintains constant gas pressure under changing demand and conditions
- Auto Changeover: Features an automatic switch system that connects two propane tanks simultaneously and switches between them when one runs out, preventing sudden gas interruption and equipment shutdown. Red indicator light shows the tank is empty or off; Green light indicates normal operation
- Specification: Propane gas regulator primary cylinder capacity 210,000 BTU/HR, reserve cylinder 130,000 BTU/HR. Regulator inlets are QCC1 1/4" SAE inverted flare, outlet is 3/8" female NPT. 18" RV pigtail propane hose with 1/4" male quick-disconnect connect plug and QCC1 fitting
- Durable Construction: Built with stainless steel braided hoses and solid brass fittings for rust and corrosion resistance, and a secure, leak-free connection. The glow-in-the-dark tank pressure gauge allows you to easily monitor propane levels and detect leaks without removing the tank. All components are CSA certified for outdoor-safe performance
- PACKAGE INCLUDED: 2 Stage automatic conversion rv lp propane regulator, 2 * 18" pigtails propane hoses with gauge, 48" stainless braided regulator hose, 3/8" NPT male & male flare, roll sealing tape, wrench, screws, regulator bracket
- WIDE APPLICATION: This propane gas regulator is ideal for RVs with dual propane tanks and works with most motorhomes, campers
, travel trailers, BBQ grills, heating needs, and outdoor cooking applications
- High Pressure Output for Heavy-Duty Systems: This rugged regulator delivers a fixed 30 PSI outlet, ideal where lbs of pressure (not inches water column) are required for heaters, grills, and larger RV appliances
- Massive Capacity Handles High Demand: Rated for 500,000 BTU/hr, this high-capacity propane regulator supports dual tank systems, generator hookups, and extended road use under full LP load
- Installs in Minutes: The compact design measures 4.02″ x 3.35″ x 2.8″ and weighs around 7 oz., so it fits tight spaces and installs in minutes on camper
hookups, tank mount, or under-hood setups - Easy Replacement or Upgrade: 1/4″ FPT inlet and 1/4″ FPT outlet thread into common LP gas lines and regulator kits, so you can easily swap in without re-plumbing your RV tank system
- Trusted Performance, Superior Value: Zinc alloy housing and precise factory adjustment offer dependable propane pressure in cold weather, on the road, in RVs, trailers, or house style setups
- Designed to make your life easier - no more manually switching propane tanks! This regulator automatically switches to the full tank when one becomes empty, indicated by a red indicator window. And with pigtails included and a light weight of only 2.5 pounds, it's convenient to use and transport.
- Versatile and reliable - Perfect for any outdoor setting, from camping trips to backyard BBQs. The QCC1 hoses feature a flow limiter and check valve for added safety. Plus, its compact design (2 ¾"W x 6 ¼"H x 6 ¼"D) won't take up too much space in your storage or on your dual propane tank holder.
- High quality construction - Made with durable materials for long-lasting use, this propane regulator can handle up to 250 PSI of maximum working pressure. Its threaded inlets (¼" female NPT) ensure a secure connection, while the outlet (⅜" female NPT) provides steady fuel flow for all your propane needs.
- Keep your appliances going without any interruptions - Trust in our propane automatic changeover regulator to provide reliable gas supply for all your outdoor cooking needs. Upgrade your setup today!
Last update on 2026-05-24 / Affiliate links / Images from Amazon Product Advertising API
This product presentation was made with AAWP plugin.